SAE AS 1055E-2017 Fire Testing of Flexible Hose Tube Assemblies Coils Fittings and Similar System Components.pdf
《SAE AS 1055E-2017 Fire Testing of Flexible Hose Tube Assemblies Coils Fittings and Similar System Components.pdf》由会员分享,可在线阅读,更多相关《SAE AS 1055E-2017 Fire Testing of Flexible Hose Tube Assemblies Coils Fittings and Similar System Components.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS1055E AEROSPACE STANDARD AS1055 REV. E Issued 1969-02 Reaffirmed 2013-01 Revised 2017-10 Supe
5、rseding AS1055D Fire Testing of Flexible Hose, Tube Assemblies, Coils, Fittings, and Similar System Components RATIONALE Add zero flow types. 1. SCOPE This SAE Aerospace Standard (AS) establishes uniform requirements and procedures for the fire testing of flexible hose assemblies and rigid tube asse
6、mblies (including coiled tubes) to be used in aircraft or aerospace vehicle fluid systems. These procedures may also be followed for fire tests on other piping components as specified by the customer. It also refers to standard fire test equipment to be used in conducting “referee“ fire tests. 1.1 C
7、lassification Component assemblies shall be designated by Type and Class according to fire test duration and usage. Flame test apparatus and temperature shall be the same for each Type and Class. 1.1.1 Types Type Ia - Hose Assembly, Rubber - Fuel and Oil Systems Type Ib - Hose Assembly, Rubber - Hyd
8、raulic Systems Type Ic - Hose Assembly, Rubber - Zero Flow Systems Type IIa - Hose Assembly, Polytetrafluoroethylene - Fuel and Oil Systems Type IIb - Hose Assembly, Polytetrafluoroethylene - Hydraulic Systems Type IIc - Hose Assembly, Polytetrafluorethylene - Zero Flow Systems Type IIIa - Rigid Tub
9、ing Assembly - Fuel and Oil Systems Type IIIb - Rigid Tubing Assembly - Hydraulic Systems Type IIIc - Rigid Tubing Assembly - Zero Flow Systems SAE INTERNATIONAL AS1055E Page 2 of 6 NOTES 1. The Types listed above, when tested to higher pressures, temperatures, and lower flow rates do not have to be
10、 retested to qualify to lower pressures, low temperatures, and/or higher flow rates. 2. An index of the types of assembly by specification is contained in Appendix A. 1.1.2 a. Class A - Fire Resistant: 5 minutes b. Class B - Fireproof: 15 minutes NOTE: The user of this document is cautioned that the
11、 class designation relates only to assemblies tested under the specified flow conditions. 2. APPLICABLE DOCUMENTS The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall
12、 be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has
13、 been obtained. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or +1 724-776-4970 (outside USA), www.sae.org . AIR1377 Fire Test Equipment for Flexible Hose and Tube Assemblies AS150 Hose Assembly, T
14、ype Classifications of, Basic Performance and Fire Resistance AS1072 Sleeve, Hose Assembly, Fire Protection 2.2 FAA Publications Available from Federal Aviation Administration, 800 Independence Avenue, SW, Washington, DC 20591, Tel: 866-835-5322, www.faa.gov. Federal Air Regulation (FAR) Code of Fed
15、eral Regulations Volume 14, Airworthiness Standard Powerplant Engineering Report No. 3A 3. QUALIFICATION The component assemblies furnished under this document shall be products which have been tested and passed the fire test requirements listed herein. These products shall also have been tested and
16、 passed the performance requirements of the latest applicable specifications, or other applicable specifications designated by the purchaser. Test report(s) proving qualification of products to this specification shall be furnished by the supplier to the purchaser and to such cognizant agencies desi
17、gnated by the purchaser, for acceptance of qualification. Qualification by similarity, to assemblies or parts previously tested and qualified, shall be acceptable. SAE INTERNATIONAL AS1055E Page 3 of 6 3.1 Materials The component materials shall be uniform in quality, free from defects, consistent w
18、ith good manufacturing practices, and shall conform to the applicable specifications listed in 2.1 and 2.2, or other applicable specifications designated by the purchaser. 3.1.1 When firesleeves are employed to meet the fire test requirements, they shall be compatible with fluid and ambient environm
19、ents encountered and be free of corrosive additives and free from wicking action. Wrapped type firesleeves, where used, shall be arranged to approximate the installed condition that gives the least fire protection. NOTE: AS1072 indicates compatibility of firesleeves with various fluids. 4. TEST PROC
20、EDURE Test procedure shall conform with the following conditions: 4.1 Pretest Conditions 4.1.1 Flame Temperature and Size The flame temperature shall be 2000 F 150 F (1090 C 83 C) along centerline of the flame for a minimum distance of 7 inches (178 mm). 4.1.2 Flame Intensity The flame heat content
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便