SAE ARP 5741-2010 Air Mode Active Containers Conditioning Performance《气体模式集装箱运行调节性能》.pdf
《SAE ARP 5741-2010 Air Mode Active Containers Conditioning Performance《气体模式集装箱运行调节性能》.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 5741-2010 Air Mode Active Containers Conditioning Performance《气体模式集装箱运行调节性能》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2010 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside US
4、A) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/ARP5741AEROSPACERECOMMENDEDPRACTICEARP5741 Issued 2010-11Air Mode Active Containers Conditionin
5、g Performance RATIONALEThis ARP specifies the test procedures and classification requirements for the conditioning performance of air mode active containers to ensure that the appropriate containers are selected for the effective air transportation of temperature sensitive cargoes. Operational const
6、raints can be derived from the conditioning performance test results to further ensure that the conditioning performance enables temperature sensitive cargoes to be kept within specification during the ground handling phases and air transportation cycle. FOREWORDThis SAE Aerospace Recommended Practi
7、ce (ARP) outlines supplementary requirements for the testing and performance classification of Air Mode Active Containers of all sizes. Throughout this ARP the minimum essential criteria are identified by use of the key word “shall”. Recommended criteria are identified by use of the key word “should
8、” and, while not mandatory, are considered to be of primary importance. Deviation from recommended criteria should only occur after careful consideration, extensive testing and thorough service evaluations have shown alternate methods to be satisfactory. Nothing in this ARP shall in any way cancel o
9、r reduce the status of the specifications which determine airworthiness, industry compliance, ground handling or any other characteristics of the units. This ARP refers to the conditioning performance of all air mode active containers irrespective of their size and designation and where the performa
10、nce is a function of both the active and passive components of the container. It does not provide details concerning the thermal efficiency of passive (insulation only) containers. SAE ARP5741 Page 2 of 17TABLE OF CONTENTS 1. SCOPE 31.1 Purpose . 31.2 Field of Application 32. REFERENCES 32.1 Applica
11、ble Documents 33. DEFINITIONS . 44. TESTS . 54.1 Equipment . 54.2 Test Setup . 54.3 Preconditioning . 64.4 Test Start Procedure . 64.5 Test End 64.6 Test Record . 65. TEST PROTOCOL 65.1 Performance Thresholds . 75.1.1 Upper Performance Threshold . 75.1.2 Lower Performance Threshold . 85.2 Maintained
12、 Limit 95.2.1 Upper Maintained Limit . 95.2.2 Lower Maintained Limit . 105.3 Maintained Duration 105.3.1 Upper Maintained Duration . 105.3.2 Lower Maintained Duration . 115.4 Cycle performance 125.4.1 Cycle Performance Test for Heating and Cooling Container 125.4.2 Cycle Performance Test for Cooling
13、 Only Container 125.4.3 Cycle Performance Test for Heating Only Container . 136. CLASSIFICATION. 147. OPTIONAL TESTS . 147.1 Alternative set points . 147.2 Load 147.3 Temperature recorder . 158. TEST DOCUMENTATION 16SAE ARP5741 Page 3 of 171. SCOPE 1.1 Purpose This Aerospace Recommended Practice (AR
14、P) defines a series of test procedures to determine the temperature conditioning performance of air mode containers with active conditioning systems, a classification system for air mode containers with active condition systems, a standard means of expressing conditioning performance within each cla
15、ssification and a standard means of documenting test results. 1.2 Field of Application This ARP is intended to provide users, purchasers and operators with a single method for testing and documenting the conditioning performance of air mode containers with active conditioning systems. The test metho
16、d identifies the limits of performance and autonomy at these limits.The conditioning performance of an air mode container with active temperature control is a function of the performance of both passive features, such as insulation material, and active features, such as heating and / or cooling syst
17、ems. This ARP applies only to air mode containers with active temperature control. ARP1523, Air Mode Insulated Containers Thermal Efficiency Requirements is the applicable standard for air mode containers with only passive features.This ARP organizes industry requirements for temperature sensitive t
18、ransportation into three performance classes. Class A, Frozen, covers a set point range of -25 C to 0 C. Class B, Cool, covers a set point range 0 C to 15 C. Class C, Room Temperature, covers a set point range 15 C to 30 C. It is not necessary for the test subject to support the full range of perfor
19、mance classes but it shall support a set point within the range of at least one of the performance classes. Within each performance class, this ARP mandates a set point to be used in the test procedures. The test procedures defined within this ARP may be repeated at alternative set points within the
20、 performance class range. The mandatory set points within each performance class range are as follows: Class A Mandatory set point -20 C. Class B Mandatory set point 5 C. Class C Mandatory set point 20 C. In the event of a failure of the conditioning systems in an air mode active container the rever
21、sionary performance of the container is solely attributable to the passive features of the design and should be in compliance with ARP1523, Air Mode Insulated Containers Thermal Efficiency Requirements. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this document to
22、 the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of the other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this docu
23、ment takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. SAE ARP5741 Page 4 of 172.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (i
24、nside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.ARP1523 Air Mode Insulated Containers - Thermal Efficiency Requirements 2.1.2 ISO Publications Available from American National Standards Institute, 25 West 43rd Street, New York, NY 10036-8002, Tel: 212-642-4900, www.ansi.org.ISO 8058
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP57412010AIRMODEACTIVECONTAINERSCONDITIONINGPERFORMANCE 气体 模式 集装箱 运行 调节 性能 PDF

链接地址:http://www.mydoc123.com/p-1023170.html