SAE AIR 1700A-1998 Upper Frequency Measurement Boundary for Evaluation of Shielding Effectiveness in Cylindrical Systems《圆柱形系统中的屏蔽有效性评估的频率测量上界》.pdf
《SAE AIR 1700A-1998 Upper Frequency Measurement Boundary for Evaluation of Shielding Effectiveness in Cylindrical Systems《圆柱形系统中的屏蔽有效性评估的频率测量上界》.pdf》由会员分享,可在线阅读,更多相关《SAE AIR 1700A-1998 Upper Frequency Measurement Boundary for Evaluation of Shielding Effectiveness in Cylindrical Systems《圆柱形系统中的屏蔽有效性评估的频率测量上界》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AEROSPACE INFORMATION REPORTAIR1700REV.AIssued 1986-01Revised 1998-12Reaffirmed 2009-11Upper Frequency Measurement Boundary forEvaluation of Shielding Effectivenessin Cylindrical SystemsFOREWORDChanges in this revision are format/editorial only.INTRODUCTIONElectrical energy leaks through a shield bo
2、th by diffusion, as Schelkunoff (Reference 1) has described; and by aperture coupling, as described by Marcuvitz (Reference 2). At low frequencies, diffusion dominates, and at high frequencies, aperture coupling dominates. A convenient way to measure this leakage is Transfer Impedance, Zt, and Trans
3、fer Admittance, Yt, because they characterize the shield leakage independent of the source (or object) of the interfering signal, and because they are also independent of the number and arrangement of conductors inside the shield and their termination. In other words, Ztand Ytare characteristics of
4、the shield alone.Since sources and receivers of electrical energy cover a frequency range of DC to over 100 GHz, shielding is likely to be needed over that range also. If shielding is required, some means of measuring its Ztand Ytare necessary. A number of methods have been proposed (References 3 to
5、 11), most of which are variations of the method of Zorzy and Muehlberger (Reference 12). Most of these methods have been limited to frequencies below 1 GHz, some considerably below. The limitation has in some cases (References 3 and 10) been instituted to simplify the data analysis, although ways a
6、round this difficulty have been suggested (References 4 and 8).Aside from limits of convenience, a transition frequency, ft, exists, beyond which the variance in measurements of Ztand Ytcan become large. The existence of this transition frequency has been recognized in military specifications (Refer
7、ences 5 and 6), where Ztmeasurements are terminated before the transition frequency is reached. In the H revision of MIL-C-38999 (Reference 6), a stirred mode technique (Reference 13) is called out for frequencies over 1 GHz, which generally includes frequencies above the transition frequency. Howev
8、er, stirred mode testing does not evaluate Zt. Methods which do not evaluate Ztor Ytbring into the measurement both the nature of the source (or object) of interference and the nature of the conductor arrangement inside the shield, as well as the SAE Technical Standards Board Rules provide that: “Th
9、is report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE revi
10、ews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2009 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or trans
11、mitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WE
12、B ADDRESS: http:/www.sae.org SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AIR1700ASAE AIR1700 Revision A- 2 -method of terminating the conductors. Such measurements are situation specific, i.e., they evaluate the shielding in
13、the configuration of, and under the conditions of, the measurement but are not generally transportable to other conditions and configurations. A non-transportable measurement may be suitable for engineering reference or to evaluate an assembled system, but it is not suitable as an acceptance test on
14、 a system component.1. SCOPE:This AIR points out that above a frequency called the “transition frequency,” variances associated with the shielding effectiveness measurements can become large. It includes the derivations to demonstrate this. This fact should be taken into account when designing shiel
15、ding for use above the transition frequency.2. REFERENCES:1. Schelknuoff, S. A., “The Electromagnetic Theory of Coaxial Transmission Lines and Cylindrical Shields,” Bell Syst Tech J., Vol 13, 532-579, Oct. 1934.2. Marcuvits, N., Waveguide Handbook, New York, McGraw-Hill, 1951.3. Publication 96-1A, I
16、nternational Electrotechnical Commission, Geneva, Switzerland, 1976.4. Madle, P. J., “Cable and Connector Shielding Attenuation and Transfer Impedance Measurements Using Quadraxial and Quintaxial Test Methods,” In IEEE 1975 Electromag. Compat. Symp. Record, 75CH1002-5 EMC, pp. 4B1b1-5.5. MIL-C-39012
17、B Amendment 1, Military Specification, Connectors, Coaxial, Radio Frequency, General Specifications for, 18 Oct. 1972.6. MIL-C-38999H Amendment 1, Military Specification, Connectors, Electrical, Circular, Miniature, High Density, Quick Disconnect, Environment Resistant, Removable Crimp Contacts.7. M
18、artin, A. R. and S. E. Emert, “Shielding Effectiveness of Long Cables,” in IEEE 1979 Int. Symp. on Electromagnetic Compatibility, San Diego, California, Oct 9-11, 1979, pp. 13-18.8. Martin, A. R. and S. E. Emert, “The Shielding Effectiveness of Long Cables, II: LTand GTR,” IEEE Trans. on Electromag.
19、 Compat., Vol. EMC-22, pp. 269-275, Nov. 1980.9. Merewether, D. E., and T. F. Ezell, “The Effect of Mutual Inductance and Mutual Capacitance on the Transient Response of Braided-shield Coaxial Cables,” IEEE Trans. on Electromag. Compat., Vol EMC-18, pp. 15-20, Feb 1976.10. Oakley, R. J. “Surface Tra
20、nsfer Impedance Measurements - a Practical Aid to Communication Cable Shield Design,” In 18th Intl Wire and Cable Symp., Atlantic City, NJ, Dec. 1969.11. Knowles, E. D., and L. W. Olson, “Cable Shielding Effectiveness Testing,” IEEE Trans. on Electromag. Compat., Vol EMC-16, pp. 16-23, Feb 1974.SAE
21、AIR1700 Revision A- 3 -2. (Continued):12. Zorzy, J., and R. F. Muehlberger, “Rf Leakage Characteristics of Popular Coaxial Cables and Connectors, 500MC to 7.5GC,” Microwave J., Nov. 1961.13. MIL-STD-1344A Notice 1, Method 3008, Military Standard Electrical Connectors, Test Methods for.14. Grivet, P.
22、, The Physics of Transmission Lines at High and Very High Frequencies, Vol. 1, New York, Academic Press, 1970.15. IEEE Standard Dictionary of Electrical and Electronic Terms, IEEE Std 100 - 1972, Definition #E151-0.16. Vance, E. F., “Shielding Effectiveness of Braided-Wire Shields,” IEEE Trans. on E
23、lectromag. Compat., Vol. EMC-17, May 1975, pp. 71-77.17. Luca, V. A., and P. I. Pressel, “The Radiation Efficiency Technique for Measuring the Shielding Effectiveness of Cylindrical Connectors at Microwave Frequencies,” In Proc. 13th Annual Connector Symp, Philadelphia, PA, 1980, pp. 366-377.3. THE
24、EXISTENCE OF A TRANSITION FREQUENCY:Any system of two or more conductors can form a transmission line. As long as the resistance of the conductors is low (e.g., a metal) and the electrical energy flowing on the line propagates in the TEM mode, the electric and magnetic field vectors are both contain
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR1700A1998UPPERFREQUENCYMEASUREMENTBOUNDARYFOREVALUATIONOFSHIELDINGEFFECTIVENESSINCYLINDRICALSYSTEMS

链接地址:http://www.mydoc123.com/p-1020062.html