1、Lessons Learned Entry: 0992Lesson Info:a71 Lesson Number: 0992a71 Lesson Date: 2001-08-03a71 Submitting Organization: JPLa71 Submitted by: Thomas C. DuxburySubject: Spaceborne Imaging Camera Contamination (1999) Abstract: Contamination analysis does not always identify contamination sources or compl
2、ex migration paths. Designs should keep camera systems and thermal control surfaces away from vent paths and/or keep sensitive surfaces covered or sealed. Designs should include mitigation measures, (application of heat) for water vapor contamination and when using structural composite materials con
3、sideration should be given to selecting low hygroscopic materials or using non-outgassing coatings.Description of Driving Event: During first use after launch, the optical surfaces of the imaging camera onboard the NASA Discovery STARDUST spacecraft were found to be contaminated, thereby degrading t
4、he image quality. The cold operational temperatures of the camera CCD detector and optics offered a convenient “cold sink“ for contamination molecules. This phenomenon occurs when free molecules migrate to the coldest available surface. This contamination may have originated from spacecraft outgassi
5、ng and/or trapped contaminates within the camera. Such events have happened in the past on U.S. and international cold-biased instruments. Heat from internal heaters (or the sun for inorganic molecules) is commonly used to remove such contaminates, and has been used successfully on this mission to i
6、mprove imaging quality.Following the successful removal of contaminants through the heating process, a recontamination of the camera optical surfaces occurred as the temperature gradient between the spacecraft and the camera optical components returned to its nominal value (warm contamination source
7、s and cold optical surfaces). Using internal heaters again removed the contaminants.Lesson(s) Learned: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Theoretical contamination analyses may not always identify all contamination sources and complex mi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS09922001LESSONSLEARNEDSPACEBORNEIMAGINGCAMERACONTAMINATION1999PDF

链接地址:http://www.mydoc123.com/p-1018637.html