REG NASA-LLIS-0066-1992 Lessons Learned - Dewar Vent Plumbing.pdf
《REG NASA-LLIS-0066-1992 Lessons Learned - Dewar Vent Plumbing.pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-0066-1992 Lessons Learned - Dewar Vent Plumbing.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Lessons Learned Entry: 0066Lesson Info:a71 Lesson Number: 0066a71 Lesson Date: 1992-03-26a71 Submitting Organization: KSCa71 Submitted by: David PenningtonSubject: Dewar Vent Plumbing Description of Driving Event: A liquid helium dewar used to service payload experiments ruptured and damaged ceiling
2、 tiles and a copy machine. In order to service the payload experiments, the dewar converts normal liquid helium to superfluid helium. During this process, air was ingested into the vent line through a valve stem. The ingested air froze, forming a solid blockage. The failure analysis of the liquid he