1、MIL-T-81782C(AS) -11 July 1977 . Superseding - 6 December 1974 . MIL-T-8X782B (AS) MILITARY SPECIFICATION TEST STATION, COMPUTER 05-2 16 ( ) /Am- 23 (V) This specification has been approved by the Naval Air Systems Command, Department of the Navy . _. 1, SCOPE 1.1 Scope. This spekification covers th
2、e performance, design, and test ,- requirements for the Computer Test Station (CTS) 05-216( )/AW _EQ_ - _s -i-si-iii 3.2,1. Method - of operation. Applicable. -3- Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-BL782C 47 m 777770b 0256684 3 3.2
3、.1.2 Commercial test equipment. Applicable. 3.2.1.2.1 Other commercial components. Applicable. 3.2.1.3 Circu3t grounds. Applicable. 3.2.1.4 Interchangeability. Applicable. 3.2.1.5 Identification of product. Applicable. 3.2.1.6 Human factors. Applicable, 3.2.1.7 Test set generated acoustic noise. App
4、licable. 3.2.1.8 Forced-liquid cooling. Not applicable. 3.2.1.9 Space and weight limitations; The weight of the CTS shall be Maximum dimensions shall be 96 inches by 36.25 less than 4000 pounds. inches by 75 inches with all drawers and retractable work surfaces in the retracted position. 3.2.1.9.1 S
5、torage space. Storage space shall be provided in two locations in compute;- bay. no. 4. One storage area shall be located to the right of Control, Logic, Magnetic Tape Reader C-9182( )/AWM-23(V). immediately above the work surface, and shall be used to stow any simulator or the slave digi- tal compu
6、ter weapon replaceable assembly (WRA) when it is removed. other storage area shall be provided within the drawer located below the retractable work surface. This storage.area shall be used for stowage of test leads and magnetic tape reels and will provide some space for manuals. In addition, a minim
7、um of three cubic feet of separate storage facilities will be required to store miscellaneous equipment. The 3.2.1.10 Connectors. Applicable. 3;-2.1,11 Secondary electrical power. The total secondary electrical , power shall be limited to 1900 watts maximum with any combination of power form loading
8、 within the load capability limits for each power form listed in Table I. oms. facility line voltage variations shall not exceed 2 percent at the voltage sense point. volts (mV) peak-to-peak (p-p). Secondary electrical power shall consist of regulated power Regulation from no load to full load, and
9、for normal values of Ripple voltage for dc power forms shall not exceed 150 milli- 3.2.1.12 interface. Applicable. 3.2.1.12.1 Clean air interface. The CTS shall interface with the clean 3.2.1.12,2 . air through ducts which enter the CTS at the top rear of each test console. Electrical power interfac
10、e. The CTS shall interface with The CTS ._ .eiectrical power for the convenience outlets at one end of the convenience :,:outlet strip mounted on the top of the front face of the CTS. t shall interface with all other electrical power through power lines enter- 461, Test RE04 shall apply except the t
11、est shall be limited to the area occupied by the WRAs containing memory assemblies. The magnetic field shall be less than 5 gauss. MIL-STD-461, Tests CEO1 and CE03 and the limits therein shall apply 3.2.7 Utilities protection. Applicable except as follows. 3.2.7.1 Liquid cooling protection. Not appl
12、icable. 3.2.7.2 Clean air protection. Applicable. 3.2.7.3 Electrical power protection. Applicable. 3.2.7.3.1 Secondary voltage protection. Occurrence of an out-of- tolerance secondary voltage condition that could damage either an item under test or the test station shall result in automatic shutdown
13、 of the secondary power forms. shutdown shall be identified by an appropriate indicator, Operator action shall be required to reinstate test station operation after the occurrence of automatic shutdown. The out-of-tolerance condition leading to - 7- Provided by IHSNot for ResaleNo reproduction or ne
14、tworking permitted without license from IHS-,-,-MIL-T-81782C 47 7777706 025bb88 O MIL-T-81782C(AS) 3.2.7.3.2 Emergency shutdown switches. Emergency shutdown switches shall be provided for use by the operator. on the power distribution panel in bay no, 4: the other on the electrical dummy load in bay
15、 no. 1. momentary contact type with the push-button finished in red. The switches shall be superimposed on a bright orange-yellow and black diagonal striped background. CTS and the load side of all primary circuit breakers shall be disconnected from their respective loads. and independent of all uti
16、lity power forms. One switch shall be located Both switches shall be push-button activated, Activation of either switch shall result in shutdown of the Emergency power shutdown shall be fail-safe 3.2.8 Calibration cycle. Applicable. 3.2.9 Power switching and coolant control. The CTS shall provide th
17、e necessary switching to control utility power forms and.shal1 provide ori- , fices and flow switches as required for control of clean air. 3.2.10 Displays. Displays shall be provided for: a. indicating station status b. Monitoring the test performance c. d. Examining the contents of the computer re
18、gisters Signaling the operator when operator action is required 3.2.11 Operator controls. Operator controls shall be provided for selecting test options and controlling the automatic test program. 3.2.12 Tapels). Tape (or tapes) required for the CTS shall be of 1/2 inch Mylar magnetic tape, or equiv
19、alent. Maximum reel diameter shall be 8-162 inches. CTS maintenance tape(s) shall contain the programs required to verify performance of the WRAs listed in Table III and shall also con- tain diagnostic test routines for fault isolation in malfunctioning WRAs. CTS maintenance tapes shall also contain
20、 programs for self test of the CTS. A different tape containing the tactical and built in test (BIT) programs shall be provided, but not as part of the test station. 3.3 Performance, 3.3.1 General. The CTS shall provide the.capability to test and main- tain the equipment listed in Table III. 3.3.2 O
21、rganizational level.functiona1 requirements. Not applicable. 3.3.3 Interme r ement s. App 1 icab 1 e. 3.3.4 Warmup time. Applicable. 3.4 Detailed functional requirements. - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-L782C LI9 M 9779906 025
22、hb9 2 ITEM NUMBER MI L-T- 8 17 8 2 C (AS) TABLE III WRAs MAINTAINED AT THE CTS WRA NOMENCLATURE Computer, Digital CP-1159( )/AWG-9 Memory Unit M-588( )/AWG-9 Processor, Data CV-3151( )/AWG-9 and CV-3165 ( )/AWG-g. Power Supply-Stozer PP-6776( )/AWG-9 Converter, Signal Data CV-3152( )/AWG-9 Control,
23、Logic-Timing C-9506( )/AWG-9 3.4.1 Maintenance capabilities. The CTS shall be capable of loading program data into the non-destructive read-out (NDRO) of the memory unit and into the bulk store of the power supply - storer memory. The CTS shall provide and control the stimuli and power forms., and p
24、rovide loads required to perform functional and diagnostic testing of the WRAs listed in Table III. 3.4.2 Test capabilities. Unless otherwise specified herein, functional and diagnostic testing of WRAs shall be performed automatically. programmable counter/timer and the digital ratiometer voltmeter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT81782C1977TESTSTATIONCOMPUTEROJ216AWM23VOJ216AWM23V 电脑 测试 PDF

链接地址:http://www.mydoc123.com/p-982856.html