NAVY MIL-T-19383 A-1968 TEST SET SYNCHRO TRANSMITTER MARK 312 MOD 0 (FOR TORPEDO MARK 37 MODS 0 2 AND 3)《37号0 2 及3型鱼雷312号0型同步发送器测试装置》.pdf
《NAVY MIL-T-19383 A-1968 TEST SET SYNCHRO TRANSMITTER MARK 312 MOD 0 (FOR TORPEDO MARK 37 MODS 0 2 AND 3)《37号0 2 及3型鱼雷312号0型同步发送器测试装置》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-T-19383 A-1968 TEST SET SYNCHRO TRANSMITTER MARK 312 MOD 0 (FOR TORPEDO MARK 37 MODS 0 2 AND 3)《37号0 2 及3型鱼雷312号0型同步发送器测试装置》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-19383A (OS) 28 February 1968 Superseding MIL-T-19383 (Nord) 21 March 1956 MI T TEST SE“, RY SPEC1 FI CATI-ON SYNCHRO TRANSMITTER MK 312 M.0D O (For Torpedo Mk 37 Mods O, O(M) , 1, 2, and 3) This specification has been ,approved by the Naval Ordnance Systems Command, Department of the Navy . 1.
2、 SCOPE 1.1 Scope. This specification describes the requirements for themurement ofa synchro transmitter test set, LD 482753 and Drawing 1583207, capable of replacing and simulating the functions of the course gyro of Torpedo Mk 37 Type in system tests performed on the torpedo. The synchro transmitte
3、r is required to simulate any given angular position of the course gyro spin axis relative to the torpedo-longitudinal axis and to present on the concentric dial assembly a precise indication of this angular position in degrees and minutes. The test set front panel also presents an indication of the
4、 course gyro caged condition. 2. APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effect on date of invitation for bids or request for proposal form a part of this specification to the extent specified herein. SPECIFICATIONS MIL I TA RY MIL-T-945 MIL-E-17555 Test Equipment, For Use W
5、ith Electronic Equipment; General Specification Electronic and Electrical Equipment and Associated Repair Parts; Preparation for Delivery of . y THIS DOCUMENT CONTAINS 13 PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-l9383A(OS) STANZ)A
6、RDS MILITARY MIL-STD-105 DRAWINGS Sampling Procedures and Tables for Inspection by Attributes NAVAL ORDNANCE SYSTEMS COMMAND LD 482753 Test Set, Synchro Trans- mitter Mk 312 Mod O, and all parts and subassemblies listed thereon. Dwg 1583207 Test Set, Synchro Transmitter, Mk 312 Mod O, Assembly PUBLI
7、CATIONS NAVAL ORDNANCE SYSTEMS COMMAND WR-43 Preparation of Quality Assurance Provisions (Including Classification of Characteristics) OS 6341 Miscellaneous General Ordnance Design Requirements (Copies of specifications, standards, drawings, and publi- cations requested by contractors in connection
8、with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on date of
9、invitation for bids or request for proposal shall apply. NATIONAL BUREAU OF STANDARDS PUBLICATIONS Handbook H28 Screw-Thread Standards for Federal Services (Applieation for copies should be addressed to the Superintendent of Documents, Government Printing Office, Washington, D. C. 20402) 2 Provided
10、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-17383A 66 M 3777706 0327733 T MIL-T-l9383A(OS) 3. REQUIREMENTS 3.1 Description. The synchro transmitter is a portable test set consisting primarily of a synchro, a concentric dial assembly, hand wheel, pil
11、ot light, and a 14-pin connector. The synchro transmitter is electrically identical to the synchro in Gyro Mk 39 Mod O, and-when connected to the torpedo during a test, it simulates the synchro output of Gyro Mk 39 Mod O and its caging-circuit functions. The synchro trans- mitter can be positioned a
12、t any heading by means of the hand wheel, with the dial assembly indicating the heading. The fine dial is calibrated from O to 10 degrees in 10 minute graduations; the course dial is calibrated from O to 360 degrees in 10 degree graduations. External electrical connections to the test set are made t
13、hrough a single cable 8 feet in length, terminating in a male connector with mating surface pin arrangement and polarity identical to that of the course gyro which it replaces. 3.2 General requirements 3.2.1 Contractor-furnished data. Data required by this specification or by applicable documents re
14、ferenced in Section 2 need not be furnished unless specified in the contract or order (see 6.2). 3.2.2 Preproduction-.samples. Unless otherwise specified in the contract or order preproduction samples of the synchro transmitter shall be manufactured using the methods and procedures proposed for the
15、production lot, These samples will be tested as specified in Section 4 herein and are for the purpose of determining that the production item meets the requirements of this specification and the design. See 4.2.1. 3.2.3 Materials. Unless otherwise specified in the contract, requisition, or order, al
16、l materials and purchased parts entering into the final assembly of the synchro trans- mitter shall conform strictly to the detailed requirements indicated on the drawings and specifications listed in LD 482753. 3.2.4 Finishes, coating, construction, and dimensions. Finishes, coating, construction,
17、and dimensions for the synchro transmitter shall be strictly in accordance with the applicable drawings, specifications, and publications listed in LD 482753. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-19383A (OS) 3.2.5 Moisture, fungus,
18、 and corrosion. The synchro transmitter shall b e rendered moisture, fungus, and corrosion resistant as required by NAVORD OS 6341. 3,2.6 Marking. Marking of assemblies, subassemblies, and parta shall conform to the applicable drawings listed in LD 482753. 3.2.7 Interchangeability. Care should be ex
19、ercised in the fabrication of component parts to obtain proper sizes and to ensure proper fitting and interchangeable assembly of such parts without interference, binding, or misalignment and without resorting to selection or selective fitting. When required by the design, interference fits will be
20、detailed on the applicable drawings. 3,2.8 - Gages. The contractor shall provide himself with whatever gages are necessary and adequate to ensure that the material to which this specification applies will meet the dimensional requirements shown on the applicable drawings. If so stipulated in the con
21、tract, order, or requisition, the government will furnish drawings of pertinent Navy Final Inspection Gages for guidance in the design of the contractors inspection gages. However, such procedure shall not serve to relieve the contractor of his responsibility in the design and manufacture of such ga
22、ges as may be required for the satisfactory fulIillment of the contract requirements, but is intended to facilitate acceptance of all components and assemblies by Navy Final Inspection Gages. 3.2.9 Threads. Unless otherwise specified, all threads shall be in accordance with National Bureau of Standa
23、rds Handbook H28. The class or fit for threads shall be as specified on the applicable drawings, 3.2.10 Conflicting requirements. Conflicting require- ments arising between this specifkation or any specifica- tions, publications, or drawings listed herein shall be referred in writing to the procurin
24、g agency or appointed agent for interpretation, clarification, and resolution (Or correction). 3.3 Definitions. Definitions applicable to environmental requirements of th is specification are defined in MIL-T-945. 4 .-. Provided by IHSNot for ResaleNo reproduction or networking permitted without lic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT19383A1968TESTSETSYNCHROTRANSMITTERMARK312MOD0FORTORPEDOMARK37MODS02AND337 02 鱼雷 312 同步 发送 测试

链接地址:http://www.mydoc123.com/p-982561.html