1、MIL-G-18853C 13 m 999990b 0299925 5 -, 1 MIL-G-l8853C(OS) 29 August 1975 Superseding MIL-G-18853B (Wep ) 5 February 1962 with Amendment - 7 3 June 1969 MILITARY SPECIFICATION GYRO, RATE (FOR TORPEDO MARK 37 MODS 2 AND 3) This specification is approved for use by all Departments and Agencies of the D
2、epartment of Defense. 1. SCOPE 1.1 Scope. This specification describes the requirements for the procurement, inspection, and test of a rate gyro. 2. APPLICABLE DOCUMENTS 2.1 Referenced documents. The following documents of the issue in effect on date of invitation for bids or request for proposals f
3、orm a part of this specification to the extent specified herein. SPECIFICATIONS Military MIL- P- 116 Preservation - Packaging, Methods of NIL-E-82590 Environmental Requirements and Tests (For Torpedo MK 37 Components) Q STANDARDS Military MIL-STD-454 Standard General Requirements for Electronic Equi
4、pment DRAWINGS Naval Sea Systems Command (Code Ident. 10001) LD 480480 Rate Gyro Assembled, and all parts and subassemblies listed thereon - TH85 h i 3 Itr 0.75 volts; and 5 C 0.75 volts. At each of the three speeds, record the voltage reading and turning rate in degrees per second. j. Rotate the tu
5、rntable in a counterclockwise direction, when viewed from above, at three speeds such that the voltmeter reads 1 I 0.75 volts, 3 C 0.75 volts and 5 t 0.75 volts. At each of the three speeds, record the voltage reading and turning rate in degrees per second. k. Using Figure 1, plot the six points rec
6、orded (three points in 4.5.3.i and three points in 4.5.3.j). limits of the shaded area of Figure 1. These points must fall within the -. I I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provided by IHSNot for ResaleNo reproduction or networking pe
7、rmitted without license from IHS-,-,-4.5.4 Test procedure for maximum output. To test the rate gyro maximum output for the requirements of 3.3.3: a. Connect the rate gyro and confirm the power and current require- ments as described in 4.5.3.b. through g. b. Remove the cover (see Dwg 1523749). c. Ma
8、nually force the gimbal and motor subassembly over to each stopscrew (Dwg 1539007) as shown on Dwg 1503477. shall be as specified in 3.3.3, when the stop is against the stopscrew on each side. The output voltage 4.5.5 Test procedure for phasing. To test the rate gyro phasing for the requirements of
9、3.3.4: a. Mount the rate gyro as described in 3.3.4. b. Connect the rate gyro and confirm the power and current require- ments as described in 4.5.3.b. through f. c. Install a jumper between pins E-F of P601. d. Set the vacuum tube ac voltmeter on the 100 volt scale and connect it to pins D-H of P60
10、1. if the power source is as specified in Table I, Item 5. The voltmeter shall read 55 $: 1 volt (1) When the rate gyro is rotated in a clockwise direction, (as viewed from above), the voltmeter reading shall increase from 55 $: and shall remain at this increased reading as long as the gyro is being
11、 turned at a steady rate. volt (2) When the rate gyro is rotated in a counterclockwise direction (as viewed from above), the voltmeter reading shall decrease from 55 t: 1 volt and shall remain at this decreased reading as long as the gyro is being turned at a steady rate. 4.5.6 Test procedure for ze
12、roing. To test the rate gyro zeroing for the requirements of 3.3.5, mount and connect the rate gyro and confirm the power and current requirements as described in 4.5.3.a. through g. a. With the rate gyro stationary, the voltmeter shall read 0.15 volt maximum as specified in 3.3.5.1. b. With the rat
13、e gyro rotated at 44 degrees per second minimum clockwise, then stopped, then rotated counterclockwise and stopped, the null voltages shown on the voltmeter shall be within 0.03 volt of the null voltage obtained in 4.5.6.a. This procedure shall be repeated a minimum of three times in each direction.
14、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-P MIL-G-18853C 13 W 7777906 0297937 L MIL-G- 188 5 3C ( OS ) c. With the rate gyro resting on either end, or either side, the voltmeter shall read within 0.03 volt of the null voltage obtained in 4.5.6
15、.a. as specified in 3.3.5.2. 4.5.7 Test procedure or spin-axis alignment. To test the rate gyro spin axis alignment for the requirements of 3.3.6: a. Position the gyro fixture on the turntable so that the gyro base is in the same plane as the turntable (with the base down). b. Connect the rate gyro
16、and confirm the power and current require- ments as described in 4.5.3.b. through g. c. Rotate the turntable either clockwise or counterclockwise, at 10 f 1 degree per second. 0.05 volt from the null voltage obtained in 4.5,S.a. The voltage shall not change by more than 4.5.8 Test procedure for line
17、arity. If the sensitivity requirements as described in 4.5.3 are met, the linearity as described in 3.3.7 will be obtained. 4.5.9 Test procedure for insulation. To test the rate gyro insulation for the requirements of 3.3.8, the gyro must be at temperatures and humidity conditions specified in 4.5.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILG18853C1975GYRORATEFORTORPEDOMARK37MODS2AND3MK47MODS23 鱼雷 回转 速率 PDF

链接地址:http://www.mydoc123.com/p-979281.html