1、AMSC N/A Page 1 of 8 FSC 6140 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited INCH-POUND MIL-PRF-81757/22(CR) 25 FEB 2011 PERFORMANCE SPECIFICATION SHEET BATTERY, RECHARGEABLE, NICKEL CADMIUM, VENTED, 1.2-VOLT, 13 AMPERE-HOUR, BB-475/A CELL This specification is appr
2、oved for use within Army CECOM Life Cycle Management Command, Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product herein shall consist of this specification and MIL-PRF-81757. REQUIREMENTS 1. Part o
3、r identifying number. The part or identifying number (PIN) of the cell shall be M81757/22-1. 2. Dimensions and weight. The dimensions and weight of the cell shall be as specified in 3.10.8 as modified herein and as shown on figure 1 herein. The weight of the cell shall be not greater than 1.21 pound
4、s (0.55 kg). 3. Capacity. The minimum capacity of the battery shall be 13 ampere-hours (14.2 initially). When tested as specified in MIL-PRF-81757, the test parameters and requirements of Table I herein shall apply. Copyright Communications - Electronics Command Provided by IHS under license with CR
5、AINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-81757/22(CR) 2 TABLE I: Test parameters and requirements, BB-475/A cell Test Test Method Discharge Rate(A) 1/ Cut Off Voltage(V) 1/ Capacity (Ah) Minimum 1/ Initial capacity discharge 4.5.13 13 0.95 14.2 Hum
6、idity and Charge Retention 4.5.14 13 0.95 9.75 Shock 4.5.15 330 0.53 5.5 Vibration 4.5.16 330 0.53 5.5 Temperature Shock 4.5.17 13 0.95 13 Altitude 4.5.18 13 0.95 13 Twenty-second pulse discharge 4.5.20 330 0.53 5.5 Medium Rate Discharge and Operating Position 4.5.21 117 0.76 9.7 Cycle Life 4.5.23 N
7、ormal Rate (Cycle 1) 13 0.95 13 High Rate 330 0.53 3.7 Normal Rate (Cycle 100) 13 0.95 13 Normal Rate (Cycle 200) 13 0.95 13 1/ Test parameters and requirements cited herein supersede those in the general specification. 4. Voltage. The nominal voltage of the BB-475/A cell shall be 1.2 volts. 5. MIL-
8、PRF-81757 variance. The BB-475/A cell shall comply with MIL-PRF-81757 except as follows. 5.1 Modify the following paragraph(s): 3.6.2 Fasteners. After the phrase “free of any coating” add the following: “except as otherwise specified herein.” 5.2 Add the following new paragraph: “3.7.11.9 Shipping c
9、ondition of cells. All cells shall be delivered complete with electrolyte to the proper level and completely discharged, but fully formed. Each individual cell, as supplied, shall be equipped with a shorting device across the output terminals.” 5.3 Modify the following paragraph: 3.10.22 Constant vo
10、ltage discharge. This requirement is not applicable to this battery. Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-81757/22(CR) 3 VERIFICATION 1. MIL-PRF-81757 variance.
11、 The BB-475/A cell shall comply with MIL-PRF-81757 except as follows. 1.1 Modify the following paragraphs: 4.2.1 Inspection of replaceable cells. Delete text in its entirety and replace with the following: “Five complete packages of cells (19 each) and one additional cell shall be furnished for insp
12、ection.” 4.3.3 Sample size and selection for groups A, B, and C inspection. Add the following: “Samples sizes specified for batteries shall apply to complete packages of 19 cells each.” 4.5.12 Cell vent test. Add the following after the title: “This test shall be performed on all M81757/22-1 cells i
13、n a package connected in series and configured as they would be in a M81757/21-1 (BB-664/A) or similar battery configuration (i.e., BB-476/A).” 4.5.14 Humidity and charge retention test. Add the following after the title: “This test shall be conducted with all M81757/22-1 cells in a package connecte
14、d in series and configured as they would be in a M81757/21-1 (BB-664/A) or similar configuration battery (i.e., BB-476/A).” 4.5.15 Shock. Add the following after the title: “This test shall be conducted with all M81757/22-1 cells in a package connected in series and configured as they would be in a
15、M81757/21-1 (BB-664/A) or similar configuration battery (i.e., BB-476/A). After examination, discharge at 330 amperes in three 20-second pulses with 120 seconds at rest between pulses.” “4.5.16 Vibration. Add the following after the title: “The following test shall be performed. This test shall be c
16、onducted with all M81757/22-1 cells in a package connected in series and configured as they would be in a M81757/21-1 (BB-664/A) or similar configuration battery (i.e., BB-476/A). Testing materials required are listed below. Upon completion, cells shall meet the requirements of 3.9. ITEM NSN P/N (CA
17、GEC) QUANTITY Battery Container - - 1 Bus, Conductor 6150-01-041-4581 10371-114 (74025) 18 Screw, Hex head, SS, #8-32 UNC 3A, 7/16”L 38 Washer, Spring 5310-00-118-1977 M81757/1-8A (81349) 16128-26 (74025) 38 Washer, Flat 5310-00-976-4621 162A7819-22 (01002) 38 “Notes: NSN = National Stock Number P/N
18、 = Part Number CAGEC = Commercial and Government Entity Code Copyright Communications - Electronics Command Provided by IHS under license with CRAINot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-81757/22(CR) 4 “a. Constant current charge cell assembly at th
19、e 1C rate. “b. Assemble cells and hardware into a battery container. Use of polyamide shims to secure cells in place and petrolatum lubricant is permissible but not required. “c. Attach container to vibration equipment in the normal, upright position. “d. Connect cell assembly to the test system. “e
20、. Attach no less than two accelerometers to cells in the direction of the vibration motion; use the spectral density average of accelerometers to control test levels. “f. Subject cells to the vibration test of MIL-STD-810, Method 514, Procedure I (Operational service), using Annex D parameters for C
21、ategory 14, Helicopters, vibration parameters for General Materiel, fxvalues for Main Rotor of AH-64 (early) “g. Disconnect cell assembly from vibration equipment; reattach to vibration equipment in a perpendicular axis. “h. Repeat steps d through g for a total of 3 mutually perpendicular axes. “i.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF81757222011BATTERYRECHARGEABLENICKELCADMIUMVENTED12VOLT13AMPEREHOURBB475ACELLPDF

链接地址:http://www.mydoc123.com/p-447623.html