1、MIL-Q-50385 (2) 12 H 9799906 0367577 7 H - MIL-Q;50385 (AR) AMENDMENT 2 5 January 1990 SUPERSEDING AMENDMENT 1 17 August 1984 MILITARY SPECIFICATION QUANDRANT, FIRE CONTROL: ELEVATION M14E1 This Amendment forms a part of Military Specification MIL- Q-50385(MU), dated 16 June 1970, and is approved fo
2、r use by the US Army Armament Munitions and Chemical Command and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 Title: Change “M14E1“ t “M14Al“ and wherever it appears in the specification. * 2.1 Drawings: Delete “Frankford Arsenal and substitute “Armament
3、Research, Development and Engineering Center ( ARDEC) I . Add: “5549108 Telescope, Collimating 6523553 Elevation and Cross Leveling Fixture 8565834 Test Adapter for Quadrant“ PAGE 2 * 3.3 Delete and substitue: 3.3 “General Specification“. The contractor shall be responsible for the compliance with t
4、he requirements of specification MIL-F-13926“. PAGE 4 * 3.10 Delete the last sentence. Add new paragraph 3.11.3: AISC N/A FSC 1240 DISTRIBUTION STATEMENT A. c 1 of 5 Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without l
5、icense from IHS-,-,-_ MIL-Q-50385 (2) 12 7377706 0367578 O W MIL-Q-50385(AR) AMENDMENT 2 “3.11.3 External tritium contamination. There shall be no trace of tritium in excess of 1000 disintegrations per minute (dpm)/100 sq. cm. on the external surface of the mount. I PAGE 5 * 4.3.2.1 line 3: Delete “
6、listed in the . Technical Data Package (TDP I. PAGE 6 * 4.3.2.2 Table I, Major: Add “100% inspection“ Add “119 External Tritium Contamination 3.11.3 4.6.2.12.3 4.6.2.12.3 120 Counter digit alignment 121 Fabrication 3.2 Applicable Drawings, Vi su a 1 I 3.9 Delete “Minor: 201. Counter digit alignment“
7、 4.4.1 Delete and substitute: “4.4.1 Three telescopes shall be selected at random by a Government representative as a special sample from each 100 produced or from each months reproduction, whichever occurs first, and be subjected to the requirements and tests of Table II:“. Table II: Delete 301, 30
8、2, and 303. 304: Add “(-80F(-620C) and +16OoF(+7loC)“ add “Visual/Tactile“ after 4.6.1.1. 305: Add “(-40F(-400C) and +105F(+650C)“. PAGE 7 * 4.5.3 Delete items 2, 3, and 4. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-Q-50385(AR) AMENDMENT 2
9、 PAGE 8 * 4.6.2.1, line 4: Delete “Procedure V of MIL-F-13926“ * 4.6.2.2, line 4: Delete “both of .IEL 8626310.“ PAGE 10 Add new paragraphs 4.6.2.9, 4.6.2.10, and 4.6.2.11: “4.6.2.9 Azimuth adjustment. Repeat the above procedure; however, the azimuth adjustment is to be vsed in lieu of the elevation
10、 adjustment. The amount of adjustment must conform to the requirement of 3.7.5.2. 4.6.2.10 Counter numbers. Variation in the alignment of counter digits shall not exceed the limits outlined in 3.9. 4.6.2.11 Operability. The torque requirement shall be measured by means of appropriate torque measurin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILQ5038521990QUADRANTFIRECONTROLELEVATIONM14A1M14A1 火力 控制 信号 PDF

链接地址:http://www.mydoc123.com/p-447631.html