NAVY MIL-DTL-7793 2 B-2012 METER TIME TOTALIZING MINIATURE DIGITAL 28 VDC ROUND.pdf
《NAVY MIL-DTL-7793 2 B-2012 METER TIME TOTALIZING MINIATURE DIGITAL 28 VDC ROUND.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-7793 2 B-2012 METER TIME TOTALIZING MINIATURE DIGITAL 28 VDC ROUND.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/2B 19 October 2012 SUPERSEDING MIL-M-7793/2A 15 September 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 28 VDC, ROUND This specification is approved for use by all Departments and Agencies of the Department of Defense. Reactivat
2、ed after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Meter configuration. 1.000 Provided by IHSNot for ResaleNo reproduction or network
3、ing permitted without license from IHS-,-,-MIL-DTL-7793/2B 2 REQUIREMENTS: 1. Dimensions. Dimensions are in inches. Unless otherwise specified, tolerances are .02 for two-place decimals and .015 for three-place decimals. 2. Mounting flange. Meters with fixed flanges shall be tin plated on the front
4、surface of the mounting flange in accordance with ASTM-B545 to provide an electrical ground for the case. In accordance with Table I, meters may be furnished with no flange or with adjustable split mount flanges in accordance with MS3345-1. 3. Life accuracy. Meter accuracy shall be 0.1 percent from
5、-85 to 257 F (-65 to 125 C) and 10 to 34 VDC. 4. Power consumption. The average power consumption at 28 volts direct current (VDC) shall not be greater than 85 milliwatts. 5. Ripple voltage. The meter shall continue to operate as specified in MIL-DTL-7793 when subjected to a cyclic peak of ripple vo
6、ltage (see Note 3) of less than 2.0 VDC and the frequency-voltage coordinates of figure 2. 5.1 Ripple voltage measurement. The ripple voltage shall be measured with a peak reading voltmeter in series with a 4.0-microfarad capacitor. The higher of the two values measured when the voltmeter is success
7、ively connected to each of two polarities shall be considered the ripple voltage. 5.2 Frequency characteristics. The frequency components of the ripple voltage shall be within the limits on figure 2 when measured as conducted interference. 6. Operating temperature range. The operating temperature ra
8、nge shall be from -85 to 257 F (-65 to 125 C). 7. Voltage range. The operating voltage shall be from 10 to 34 VDC. 8. Time range. Total readout of the meters shall be 9,999 hours. 9. Transient protection. No temporary or permanent degradation shall be produced in the meter for the input voltage and
9、time values shown on figure 3 and figure 4 (80V and 600V transient, respectively). 9.1 Transient voltage. Transient surge voltages shall be within the limits on figure 3 when converted to their equivalent step functions. Transient spike voltages shall be within the limits shown on figure 4. They sha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL77932B2012METERTIMETOTALIZINGMINIATUREDIGITAL28VDCROUNDPDF

链接地址:http://www.mydoc123.com/p-978872.html