1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/14A 19 October 2012 SUPERSEDING MIL-M-7793/14 15 December 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 28 VDC OR 26 VAC, 50 TO 2400 Hz, SQUARE This specification is approved for use by all Departments and Agencies of the Depart
2、ment of Defense. Reactivated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Meter dimensions. Provided by IHSNot for ResaleNo reprod
3、uction or networking permitted without license from IHS-,-,-MIL-DTL-7793/14A 2 REQUIREMENTS: 1. Dimensions. Dimensions are as specified in Figure 1. All dimensions are in inches. Unless otherwise specified, tolerances are 0.02 for two-place decimals and 0.015 for three-place decimals. 2. Mounting fl
4、ange. The mounting flange, threaded extension and threaded protection cap shall be constructed of aluminum alloy with an olive drab chromate coating over cadmium plating. 3. Protection cap. The protection cap shall be in accordance with MS25043-10DA per SAE-AS25043 except for the finish and means of
5、 attachment. The finish shall be in accordance with that for the mounting flange in Requirement 2 above. The metallic chain shall be replaced with a nylon lanyard. 4. Dielectric strength. The meter shall be capable of withstanding the application of 600 VRMS (room) and 350 VRMS (altitude) between th
6、e terminals and the case. 5. Life accuracy. Meter accuracy shall be 0.1 percent from -85 to 257 F (-65 to 125 C) and 10 to 34 VDC, or 20 to 30 VAC at 50 to 2400 Hz. Qualification tests shall be performed on 3 meters each, for DC and AC accuracy. 5. Power consumption. Power consumption at 28 volts VD
7、C shall not exceed 50 milliwatts and at 26 VAC, 400 Hz AC shall not exceed 25 milliwatts. 6. Ripple voltage. The meter shall continue to operate as specified in MIL-DTL-7793 when subjected to a cyclic peak of ripple voltage (see Note 3) of less than 2.0 VDC and the frequency-voltage coordinates on f
8、igure 2. 6.1 Ripple voltage measurement. The ripple voltage shall be measured with a peak reading voltmeter in series with a 4.0-microfarad capacitor. The higher of the two values measured when the voltmeter is successively connected to each of two polarities shall be considered the ripple voltage.
9、6.2 Frequency characteristics. The frequency components of the ripple voltage shall be within the limits on Figure 2 when measured as conducted interference. 7. Operating temperature range. The operating temperature range shall be from -85 to 257 F (-65 to 125 C). 8. Part Number. The part number is
10、M7793/14-1. 9. Time range. Total readout of the meters shall be 99999.99 hours. 10. Meter output. The output from the meter shall be in a serial binary coded decimal format. The output impedance shall be 100K 10%. A logical “zero” shall be between 0.0 to Provided by IHSNot for ResaleNo reproduction
11、or networking permitted without license from IHS-,-,-MIL-DTL-7793/14A 3 +0.2 volt. A logical “one” shall be between +3.3 and +6.6 volts. The output pin assignments are shown in Figure 3 and the output data format as shown on figure 4. 11. Transient protection. No temporary or permanent degradation s
12、hall be produced in the meter for the input voltage and time values shown on figure 5 and figure 6 (80V and 600V transient, respectively). 11.1 Transient voltage. Transient surge voltages shall be within the limits on figure 3 when converted to their equivalent step functions. Transient spike voltag
13、es shall be within the limits shown on figure 6. They shall be not greater than 600V nor depart from the normal wave form for more than 50 microseconds. 12. Durability of cap and threads. There shall be no mechanical or electrical degradation after 100 cycles in accordance with SAE-AS50151. 13. Volt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL779314A2012METERTIMETOTALIZINGMINIATUREDIGITAL28VDCOR26VAC50TO2400HZSQUAREPDF

链接地址:http://www.mydoc123.com/p-978869.html