NAVY MIL-DTL-7793 13 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC PRINTED CIRCUIT MOUNT.pdf
《NAVY MIL-DTL-7793 13 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC PRINTED CIRCUIT MOUNT.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-7793 13 A-2012 METER TIME TOTALIZING MINIATURE DIGITAL 5 VDC PRINTED CIRCUIT MOUNT.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/13A 19 October 2012 SUPERSEDING MIL-M-7793/13 15 December 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 5 VDC, PRINTED CIRCUIT MOUNT This specification is approved for use by all Departments and Agencies of the Department of Def
2、ense. Reactivated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Bottom view. Provided by IHSNot for Resale-,-,-MIL-DTL-7793/13A 2 F
3、IGURE 2. Top view and pin assignment. REQUIREMENTS: 1. Dimensions. Dimensions are in inches. Unless otherwise specified, tolerances are .02 for two-place decimals and .015 for three-place decimals. 2. Dielectric strength. The meter shall be subjected to 600 VRMS (at 25 C 5 C) and 350 VRMS (altitude)
4、. The test voltage shall be applied between the power terminals (+5 VDC and common) and an external ground which contacts the meter case on the five sides without terminals. 3. Life accuracy. Meter accuracy shall be 0.1 percent from -65 to +125 C and 4.5 to 10 VDC. 4. Power consumption. Power consum
5、ption at 5 volts direct current (VDC) shall not be greater than 2 milliwatts. 5. Ripple voltage. The meter shall operate normally when subjected to a 2 volt peak (4 volts peak-to-peak) ripple between 10 Hz and 10 KHz superimposed on 7.0 VDC. Provided by IHSNot for Resale-,-,-MIL-DTL-7793/13A 3 6. Op
6、erating temperature range. The operating temperature range shall be from -65 to +125 C. 7. Part number. The part number shall be M7793/13-1. 8. Time range. Total readout of the meters shall be 99999.99 hours. 9. Meter output. The output from the meter shall be in a serial binary coded decimal format
7、. The output impedance shall be 100K 10%. A logical “zero” shall be between 0.0 and +0.2 volts. A logical “one” shall be between +3.3 and +6.6 volts. The output pin assignments are shown on figure 2 and the output data format is shown on figure 3. FIGURE 3. Output data format. 10. Transient protecti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL779313A2012METERTIMETOTALIZINGMINIATUREDIGITAL5VDCPRINTEDCIRCUITMOUNTPDF

链接地址:http://www.mydoc123.com/p-978868.html