1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/12A 19 October 2012 SUPERSEDING MIL-M-7793/12 15 December 1988 DETAIL SPECIFICATION SHEET METER, READER FOR SOLID STATE ELAPSED TIME INDICATORS BATTERY OPERATED, PORTABLE, HAND-HELD This specification is approved for use by all Departments and Agencies of th
2、e Department of Defense. Reactivated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Configuration of M7793/12-1. Provided by IHSNot
3、for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 2 FIGURE 2. Reader socket assignment. FIGURE 3. M7793/12-2 Replacement cable assembly. REQUIREMENTS: 1. Description of meter operation. The reader is a hand-held battery-operated instrument which can powe
4、r and read MIL-DTL-7393/13, /14, /15 and /16 solid state elapsed time indicators. The reader provides power to the reader input pin and extracts data from the output data pin of the solid state device being monitored. A third contact serves as a common. Data is transmitted over the M7793/12-2 cable
5、and connector assembly. A single pushbutton switch initiates an automatic sequence of approximately 20 seconds duration during which the data is presented on a 7-digit light emitting diode (LED) or liquid crystal (LCD) display. At the completion of the sequence, the reader turns itself off. 2. Dimen
6、sions. Dimensions shall be in accordance with Figure 1. All dimensions are in inches. Unless otherwise specified, tolerances shall be 0.1 for one place decimals. 3. Case of reader. The color shall be black for the M7793/12-1 reader. 4. Weight. The weight of the complete assembly, including battery,
7、shall be 15 ounces maximum. SOCKET ARRANGEMENT PER SAE-AS50151 10SL-C A= POWER OUTPUT TO ETI. B=COMMON FROM/TO ETI. C=OUTPUT DATA FROM ETI. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/12A 3 5. Display. The display shall have seven li
8、ght emitting diode (LED) or LED digits and two light emitting diode status indicators. The status indicators show whether elapsed time or events are being displayed. For elapsed time indication, the decimal point will also be displayed. The digit height is 0.12 inches minimum. The display must be re
9、adable from 4 to 36 inches in any ambient light, varying from total darkness to high level office lighting. The display must be readable at angles up to 20 degrees from the displays perpendicular. 6. Durability. There shall be no mechanical or electrical degradation after 100 cycles. Operational acc
10、uracy shall be checked at the end of the test. 7. Operational Temperature range. The operational temperature range shall be from -20 C to 55 C. 8. Storage temperature. The storage temperature range shall be -55 C to +85 C. 9. Altitude. The altitude (non-operational) shall be 15,000 feet maximum. 10.
11、 Vibration. Vibration shall be 10 to 55 Hz, 0.06 inch double amplitude, in accordance with MIL-STD-202, Method 201. 11. Shock. The shock shall be 50g peak, 11 ms saw tooth, in accordance with MIL-STD-202, Method 213, Test Condition G. 12. Operational accuracy. There shall be no deviation from the ac
12、tual elapsed time, as contained in the output data from a qualified MIL-DTL-7793/13 thru /16 solid state Elapsed Time Indicator (ETI). 13. Battery. Power shall be supplied by one 9 volt NEDA (National Electronic Distributors Association) Type 1604 alkaline battery or military P/N BA-3090/U. The batt
13、ery shall be installed when the reader is shipped. The battery shall have a minimum life of 1200 readings or 2 years of calendar life, whichever occurs first, at 25 C. Low battery power shall be indicated by the display flashing with a two to one intensity modulation at a 4 Hertz rate during the 15
14、second display. 14. Power consumption. The discharge current shall not exceed 80 milliamperes any time during the operational cycle while reading any valid output data. Discharge current shall not exceed 2 microamperes when non-operational. 15. Data reading. The reader shall provide an accurate disp
15、lay of time when provided with a 32 bit serial word from the solid state elapsed time indicator on socket contact C. The reader must read a logical one of +3.3 to +6.6 volts and logical zero of 0 to +0.2 volts from the elapsed time indicator. (Note: These are no load voltages prior to reader attachm
16、ent). 16. Input voltage overload protection. The reader shall not be damaged by continuous input overloads of 50 volts or transient voltages of 500 volts for up to 10 microseconds between socket contacts B and C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr
17、om IHS-,-,-MIL-DTL-7793/12A 4 17. Power output. The reader shall provide a 9 2 volt pulse at socket contact A (to power up ETI) for 3 0.5 seconds, commencing within 5 seconds after the push-to-read button is depressed. The reader must not sustain damage if the output circuit is shorted between socke
18、t contacts A and B. 18. Connector. The connector at the end of the cable assembly shall be an SAE-AS50151 modified with no threaded locking ring (modified MS3106A10SL-3S, or equivalent). The connector shall have an integral strain relief and mate with M7793/14 - /16 elapsed time indicator connectors
19、. 19. Test sequence for qualification, conformance inspection and verification of qualification. The test sequence in this specification sheet replaces the sequence in section 4 of MIL-DTL-7793. TABLE I. Qualification, verification, and conformance inspection. Test Qualification and Verification of
20、Qualification Inspection Conformance Inspection Examination of Product X X Power Consumption X X Low Battery Power X Input Voltage Overload X Power Output X X Weight X Operational Accuracy X X Altitude X Vibration X Mechanical Shock X Life X 20. Test Methods. 20.1 Examination. The reader shall be in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL779312A2012METERREADERFORSOLIDSTATEELAPSEDTIMEINDICATORSBATTERYOPERATEDPORTABLEHANDHELDPDF

链接地址:http://www.mydoc123.com/p-978867.html