1、INCH-POUND MIL-DTL-23659F 10 June 2010 Superseding MIL-DTL-23659E 27 September 2007 DETAIL SPECIFICATION INITIATORS, ELECTRIC, GENERAL DESIGN SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense 1. SCOPE. 1.1. Scope. This specification
2、 furnishes general requirements for design and establishes uniform methods for testing electric initiators and electric initiator subassemblies. The purpose of the testing program is to determine the electric characteristics, soundness of mechanical design, output, and resistance to deleterious serv
3、ice environments. For purposes of this specification the term electric initiator includes items classified in FSC 1377 such as hot wire initiators, exploding bridgewire initiators, exploding foil initiators, conductive mix initiators, etc. Electric primers are not covered in this specification. All
4、requirements for in-line initiators used in safety sensitive, non-interrupted energetic materials train applications are contained in Appendix A. Requirements for all other initiators are in the main body of this document. The term electric initiator does not include complete assemblies which have e
5、lectric initiators as subassemblies, but include only the subassemblies themselves. In addition, electric initiators must be safe for handling, transportation, storage and use and must not deteriorate to a degree, which would render their performance or safety doubtful under normal service handling,
6、 adverse storage and transportation. RF susceptibility requirements and tests have not been included in this specification. Implicit in the one watt and one ampere maximum no-fire requirements of this specification is the recognition of the hazards of electromagnetic radiation to ordnance (HERO). Th
7、is one watt and one ampere requirement in conjunction with other design requirements stated herein does not solve the HERO problem; however they do serve as a means of reducing hazards from all spurious electric sources including electromagnetic radiation. General requirements for weapon systems to
8、preclude HERO are established in MIL-STD-464. Comments, suggestions, or questions on this document should be addressed to DEPARTMENT OF THE NAVY, Indian Head Division, NSWC, Code E11G3, Document Control, 4072 North Jackson Road Suite 106, Indian Head, MD 20640-5115 OFFICIAL BUSINESS, or emailed to a
9、manda.pennnavy.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/. AMSC N/A FSC: 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by
10、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-23659F - 2 -1.2. Classification. Initiators covered by this specification are divided into two classes: Class A Includes initiators that are capable of being actuated within one second (exclusive of delay e
11、lement time, if present) from a 28 2 volt source capable of delivering not less than 10 amperes. Class B Includes initiators that are not capable of being actuated within one second (exclusive of delay element time, if present) from a 28 2 volt source capable of delivering not less than 10 amperes.
12、All requirements for exploding foil initiators used in fuzes or other safety sensitive applications are contained in Appendix A. 2. APPLICABLE DOCUMENTS. 2.1. General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include docum
13、ents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements documents cited in sections 3, 4, or 5 of
14、 this specification, whether or not they are listed. 2.2. Government documents. 2.2.1. Specifications, Standards, and Handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documen
15、ts are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 Electronic and Electric Component Parts MIL-STD-331 Fuze and Fuze Components, Environmental and Performance Tests For MIL-STD-464 Electromagnetic Environmental Effects, Requirements for Systems MIL-STD-81
16、0 Environmental Engineering Considerations and Laboratory Tests (Copies of these documents are available online at https:/assist.daps.dla.mil/ or from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia PA 19111- 5094.) 2.2.2 Other Government documents, drawings,
17、and publications. This section is not applicable to this document. 2.3 Non-Government publications. This section is not applicable to this document. 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes
18、precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-23659F - 3 -3. REQUIREMENTS. 3.1. Approval for Use of Ini
19、tiators by Service Personnel. Before any initiator or device utilizing an initiator can be used by Service personnel, it must be approved by the cognizant Safety Authority. Approval for Service use will be granted only after it has been demonstrated that the initiator has met all the requirements of
20、 this specification and adequate documentation for procurement as Government furnished equipment is completed and the release to production form has been authenticated. Interim approval can be granted prior to availability of documentation provided it has been demonstrated that the initiator has met
21、 all the requirements of this specification. Interim approval shall not exceed six months. 3.2. General. The requirements for design given in this section are considered to be the minimum requirements to which electric initiators shall be subjected. 3.3. Design. 3.3.1. General. The initiator shall b
22、e of the simplest and most efficient design (consistent with the originally proposed use) for the widest possible variety of applications. It shall be as simple and safe to assemble and install as practicable. All inert and explosive materials shall be referenced by approved Government specification
23、s where possible. Proprietary materials shall not be used unless specifically approved in writing from the cognizant Safety Authority. 3.3.2. Internal Free Volume. The internal free volume shall be minimized consistent with good design practice. 3.3.3. Weight. The weight of all initiators shall be m
24、inimized consistent with good design practice. 3.3.4. Inert Materials. Selection of inert materials shall satisfy the environmental, strength, and weight requirements set forth in the specifications for the unit of intended application. Materials which are nutrients for fungi shall not be used unles
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL23659F2010INITIATORSELECTRICGENERALDESIGNSPECIFICATIONFOR 起动器 一般 设计规范 PDF

链接地址:http://www.mydoc123.com/p-978539.html