NAVY MIL-DTL-23581 B-2009 TUMBLER DRYING LAUNDRY COMMERICAL (SUBMARINE SERVICE)《商用洗衣干燥滚筒(潜艇中使用)》.pdf
《NAVY MIL-DTL-23581 B-2009 TUMBLER DRYING LAUNDRY COMMERICAL (SUBMARINE SERVICE)《商用洗衣干燥滚筒(潜艇中使用)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-23581 B-2009 TUMBLER DRYING LAUNDRY COMMERICAL (SUBMARINE SERVICE)《商用洗衣干燥滚筒(潜艇中使用)》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Sea Systems Command, ATTN: SEA 05M2, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to CommandStandardsnavy.mil, with the subject line “Document Comment”. Since contact
2、 information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 3510 INCH-POUND MIL-DTL-23581B(SH) 13 August 2009 SUPERSEDING MIL-T-23581A(SH) 3 August 1992 DETAIL SPECIFICATION TUMBLER, DRYING, LAUN
3、DRY, COMMERICAL (SUBMARINE SERVICE) Reinstated after 13 August 2009 and may be used for new and existing designs and acquisitions. This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Departme
4、nt of Defense. 1. SCOPE 1.1 Scope. This specification covers 16-pound (minimum) capacity commercial laundry drying tumbler machines for use aboard submarines. 1.2 Classification. Drying tumblers are of the following types, as specified (see 6.2). Type I Shock qualified (see 3.7.5) Type II Not shock
5、qualified (see 3.7.5) 1.3 Part or Identifying Number (PIN). PINs to be used for drying tumblers acquired to this specification are created as follows: M 23581 - X Prefix for Military Specification Specification Number Type (see code below) Code Type 1 - Type I: Shock qualified 2 - Type II: Not shock
6、 qualified 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every
7、 effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and h
8、andbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitte
9、d without license from IHS-,-,-MIL-DTL-23581B(SH) 2 DEPARTMENT OF DEFENSE SPECIFICATION MIL-S-901 - Shock Tests. H.I. (High-Impact) Shipboard Machinery, Equipment, and Systems, Requirements for DEPARTMENT OF DEFENSE STANDARDS MIL-STD-167-1 - Mechanical Vibrations of Shipboard Equipment (Type I - Env
10、ironmental and Type II - Internally Excited) MIL-STD-740-1 - Airborne Sound Measurements and Acceptance Criteria of Shipboard Equipment MIL-STD-740-2 - Structureborne Vibratory Acceleration Measurements Acceptance Criteria of Shipboard Equipment MIL-STD-1399-300 - Electric Power, Alternating Current
11、 (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part
12、 of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) IEEE 45 - Electric Installation on Shipboard. (Copies of this document are available f
13、rom the Institute of Electrical and Electronics Engineers, Inc., 445 Hoes Lane, P.O. Box 1331, Piscataway, NJ 08855-1331 or online at www.ieee.org.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the referen
14、ces cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspect
15、ion (see 6.3) in accordance with 4.3. 3.2 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements
16、, and promotes economically advantageous life cycle costs. 3.3 Materials. Materials shall be as specified in 3.3.1 through 3.3.6. 3.3.1 Structure. Frame, base, and strength members shall be constructed of malleable iron, ductile iron, or steel and shall be hot dipped galvanized for corrosion protect
17、ion. Gray cast iron or other brittle materials shall not be used for these parts. For Type I drying tumblers, gray cast iron may be used for components other than the frame, base, and strength members provided a machine so equipped meets the shock requirements specified in 3.7.5. 3.3.2 Housing. The
18、housing shall be not less than 18 gauge sheet steel panels. Air guide baffles shall be not less than 22-gauge galvanized sheet steel. 3.3.3 Cylinder. Cylinder shall be galvanized steel sheet of not less than 18-gauge thickness. Provided by IHSNot for ResaleNo reproduction or networking permitted wit
19、hout license from IHS-,-,-MIL-DTL-23581B(SH) 3 3.3.4 Resistance wire. Resistance wire for heating elements shall conform to the following requirements: a. Chemical composition (nominal approximate): Nickel - 76.0 to 79.0 percent Chromium - 19.0 to 21.0 percent Iron - 1.0 (max.) percent Manganese - 2
20、.5 (max.) percent Carbon - 0.25 (max.) percent Silicon - 0.75 to 1.50 (max) percent Sulfur - 0.03 (max) percent b. Mechanical properties: Tensile strength pounds per square inch 100,000 minimum Elongation in 10 inches 15 percent minimum 3.3.5 Insulation. Insulation shall be of the rigid type or of f
21、ibrous glass batt type supported by cover panels. 3.3.6 Restricted materials. The drying tumbler shall be free from asbestos, wood, and cadmium materials. 3.4 Design. 3.4.1 General design. The drying tumbler shall be non-reversing, open end, once through, end loading type arranged so as not to recir
22、culate the heated air. The tumbler shall be electrically heated and provided with a thermostat that can be varied by the operator. The drying tumbler shall meet the following disassembly and reassembly requirements: a. The drying tumbler shall be constructed so that it can be readily disassembled in
23、to sections or parts that can be passed through a 30-inch diameter by 60-inch long cylinder and reassembled with a minimum of effort in the submarine laundry space. b. Cutting of parts by torch or similar means to accomplish disassembly at the site, and reassembly of parts by welding or similar meth
24、od, shall not be permitted. 3.4.2 Capacity. The machine shall accommodate or hold a load of not less than 16 pounds dry weight minimum capacity preload cotton clothing (see 6.2). 3.5 Construction. 3.5.1 Metal joints. Rivets, bolts, screws, nuts, and washers shall be of steel, except when brass or co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL23581B2009TUMBLERDRYINGLAUNDRYCOMMERICALSUBMARINESERVICE 商用 洗衣 干燥 滚筒 潜艇 使用 PDF

链接地址:http://www.mydoc123.com/p-978538.html