1、- VIL-C-28779B 59 I 9999906 0033466 7 m ) 3 - dosdJ) MIL-C-28779B( EC) 31 March 1972 SUPERSEDING MIL- C-2 8 7 7 9A( EC) 11 February 1972 (See 6.6) MILITARY SPECIFICATION COMBINER, EXTENDED FREQUENCY RANGE CU-2007 ( ) /SRR 1. SCOPE . 1.1 This specification covers the requirements for an extended freq
2、uency range combiner CU-2007( )/SRR that is intended to permit existing 2 Megahertz (MHz) to 30 MHz shipboard antennas to be used with receivers having operating frequencies below 2 MHz. 2. APPLICABLE DOCUMENTS # 2.1 The following documents of the issue in effect on date of invitation for bids or re
3、quest for proposal form a part of this specification to the extent specified herein. SPECIFICATIONS MILITARY MIL-s-901 MIL-E-16400 MIL-E-17555 MIL- F- 19 20 7 MIL-T-23103 MIL-1-45208 STANDARDS MILITARY MIL-Sh-105 MIL-STD- 10 8 MIL-STD- 109 MIL-STD-129 MIL-STD-189 - Shock Test, H.I. (High-Impact), Sh
4、p- board Machinery, Equipment and Systems, Requirements for (NAVY) Shore, General Specification Accessories, and Repair Parts, Pack- aging and Packing of - Fuseholders, Extractor Post Type, Blown Fuse Indicating and Nonindicating, General Specification for - Thermal Performance Evaluation, Air- born
5、e Electronic Equipment, General Requirement for - Electronic Equipment, Naval Ship and - Electronic and Electrical Equipment, - Inspection System Requirements - Sampling Procedures and Tables for In- - Definitions of, and Basic Requirements spection by Attributes for Enclosure for Electric and Elect
6、ronic Equipment - Quality Acsurance Terms and Definitions - Marking for Shipment and Storage - Racks, Electrical Equipment, 19-Inch and Associated Panels THIS DOCUMENT CONTAINS -.25.- PAGES FSC 5985 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL
7、- C-2 87 79B ( EC) MIL- STD-4 15 MIL-STD-461 MlL-STD-470 MIL-STD-471 MIL-STD- 781 MIL-STD- 7 85 MIL-STD- 134 5 MIL- STD- 136 4 MIL-STD-1472 HANDBOOKS MILITARY MIL-HDBK-217 MIL-HDBK-472 PUBLICATIONS MILITARY NAVSHIPS NAVSHIPS - Test Provisions for Electronic Systems and Associated Equipment, Design C
8、riteria for - Electromagnetic Interference Character- istics, Requirements for Equipment - Maintainability Program Requirements (for Systems and Equipments) - Maintainability Demonstration - Reliability Tests Exponential Dis- - Reliability Program for Systems and - Data, Measurement, in Support of t
9、ribut ion Equipment Development and Production Maintenance, Calibration, and Repair of Electronic Equipment - Preferred General Purpose Electronic Test Equipment - Human Engineering Design Criteria for Military Systems, Equipment, and Facilities - Reliability Stress and Failure Rate - Maintainabilit
10、y Prediction Data for Electronic Equipment 0967-303-8610 - Technical Manual for Antenna Coupler Groups ANISM-38, 39, 40, 49, and 50 0967-320-0010 - U.S. Navy Installation Criteria for CY-4516 (A) /S Shipboard Electronic Equipment Cab ine t (Copies of specifications, standards, drawings, and publicat
11、ions required by suppliers in connection with specific procurement functions should be ob- tained from the procuring activity or s directed by the contracting officer. ) 3. RFQUIREMENTS 3.1 General. The equipment to be supplied shall meet all the applicable detail requirements of MIL-E-16400, except
12、 as hereinafter specified. 3.1.1 First article sample. Prior to beginning production a sample shall be tested as specified in 4.3 (see 6.4). The sample shall be suitable for complete evaluation of mechanical and electrical form, design, and performance. It shall be of final mechanical and electrical
13、 form, employ standard or non- standard (when approved by the command or agency concerned) parts, and be com- pletely representative of the final equipment. 3. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-# MIL- C- 28 7 7 9B ( EC) 3.1.2 Materials.
14、 Ail materials shall be in accordance with MIL-E-16400, except as hereinafter specified. 3.1.2.1 The use of components or materials in the construction of the , complementary filter of the combiner that have nonlinear characteristics (iron core coils, for example) is prohibited. 3.1.2.2 The basic st
15、ructural material for chassis panel and enclosures shall be aluminum or aluminum alloy. 3.1.3 Selection of parts. Selection of all parts shall be as specified in MIL-E-16400. 3.1.3.1 Requests for approval for the use of nonstandard parts shall be submitted in strict accordance with the requirements
16、of MIL-E-16400. 3.2 Composition. The combiner shall consist of the following: (a) Complementary filter. (b) Active receiver multicoupler. (c) Power supply. (d) Overload protection circuit and alarm. 3.2.1 Complementary filter. A complementary filter type of signal separa- tion network shall be emplo
17、yed that shall separate incoming signals above and below the prescribed crossover frequency of 1.85 MHz. Signals below 1.85 MHz shall be passed through the low-pass section of the complementary filter and delivered to the active receiver multicoupler. Signals above 1.85 MHz shall be passed through t
18、he high-pass section of the complementary filter and delivered to existing 2 MHz to 30 MHz distribution systems. 3.2.2 Active receiver multicoupler. The active receiver multicoupler shall provide a prescribed amount of low-noise amplification and shall develop 8 isolated broadband outputs, each of w
19、hich may be connected to a separate radio receiver operating in the 10 kHz to 1.85 MHz frequency range. Appropriate overload circuitry shall be provided to protect the active multicoupler from signals of distructive amplitudes. The overload circuitry shall be integral with the active multicoupler. #
20、 3.2.3 Power supply. An appropriate power supply shall be provided to develop the necessary operating voltages for the active multicoupler. Al1 of its components shall be standard military parts. There shall be no non-standard parts as described in 3.1.3 incorporated in this section of the equipment
21、. # 3.2.4 Overload protection and alarm. An appropriate overload protection device with alarm shall be provided to meet the requirements of 3.7.6.2, 3.7.6.3, and 3.8.2.7. 3.3 Frequency range. The frequency range shall be inclusive from 10 kHz to 30 MHz. Signals below 1.85 MHz shall be delivered to t
22、he active receiver multicoupler. Signals above 1.85 MHz shall be delivered to the output for existing 2 MKz to 30 MHz distribution systems. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - MIL-C-28777B 57 W 7777706 0033467 2 W MIL-C-287 79B (EC)
23、3.4 Primary power source. The active receiver multicoupler shall operate from a 115 volt k 10 percent, 60 Hz i 5 percent, single-phase power source. 3.5 Orientation. The equipment shall be capable of storage in any orien- tation and shall be capable of operation in any angle up to 90 degrees from th
24、e normal. 3.6 Reliability. I! 3.6.1 Quantitative reliability requirement. The mean time between failure (MTBF), 8, as defined by MIL-STD-781, of this equipment shall be 30,000 hours. 3.6.2 Reliability program plan. The supplier shall submit a reliability program plan in accordance with, and in the p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC28779B1972COMBINEREXTENDEDFREQUENCYRANGECU2007SRRCU2007SRR 扩展 频带 组合 PDF

链接地址:http://www.mydoc123.com/p-977712.html