《NAVY A-A-50566-1998 MONITORING DEVICES EMISSION STACK RELATED [Superseded NAVY MIL-M-29190 A CANC NOTICE 2 NAVY MIL-M-29190 A VALID NOTICE 1 NAVY MIL-M-29190 A NAVY MIL-M-29190 (1).pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-50566-1998 MONITORING DEVICES EMISSION STACK RELATED [Superseded NAVY MIL-M-29190 A CANC NOTICE 2 NAVY MIL-M-29190 A VALID NOTICE 1 NAVY MIL-M-29190 A NAVY MIL-M-29190 (1).pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、I) A-A-50566 M 9038054 0000325 790 INCH-POUND A-A-505 66 Mav 25. 1998 SUPERSEDING 29 August 1986 MIL-M-29 190A(YD) COMMERCIAL ITEM DESCRIPTION MONITORING DEVICES, EMISSION; STACK RELATED The General Services Administration has authorized the use of this commercial item description for all Federal ag
2、encies. 1. SCOPE. This commercial item description (CID) covers emission monitoring devices for exhaust smoke stacks. 2. CLASSIFICATION. The monitoring devices shall be of the following types and classes, as specified (see 7.2): TYPE Type I - Opacity monitor. Type II - Sulfiir dioxide monitor. Type
3、III - Nitrogen oxides monitor. Type IV - Sulfur dioxide and nitrogen oxide monitor. Type V - Oxygenmonitor. Type VI - Data monitor. Class A - Chart recorder. Class B - Data acquisition system. Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may imp
4、rove this document should be sent to: Commanding Officer (Code 15E2), Naval Construction Battalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC NIA FSC 6630 Li
5、censed by Information Handling Services A-A-505bb M 9038054 O000326 627 A-A- 5 O 5 6 6 3. SALIENT CHARACTERISTICS. 3.1 Description. Continuous emissions monitoring (CEM) of gases and particulate matter from smoke stacks is accomplished by monitoring devices which analyze gas samples. These monitorin
6、g devices ensure that emissions are at acceptable levels and that combustion efficiency is at optimum levels. Emission monitoring devices include stack probes and opacity monitors. CEM analysis provides real-time readout of temperatures, pressures, flows, voltages, and currents, in addition to gas c
7、oncentrations. Data is processed through acquisition and handling systems. Types II, III, and IV monitors with automatic calibration shall be used in larger plant installations (250,000,000 British thermal units tu) (263 764 O00 kilojoule (kJ) and larger) and should not be ordered for smaller plants
8、. 3.1.1 Performance. When required by plant size to be monitored, the monitoring devices shall be in conformance with federal, state, and local regulations in effect on the date of invitation for bids or request for proposal. Routine maintenance, repair, and replacement of component parts and module
9、s shall be capable of being performed by journeyman boiler plant operators and journeyman electronic technicians. Monitoring devices specified for use on 250,000,000 Btu (263 764 O00 kJ) and larger plants shall meet the requirements of 40 CFR part 60, appendix B, performance specifications 1,2, and
10、3. Installation, plant size, location, duct/stack type and diameter, gas temperature range, corrosive components, condensate, surface and distance between the sensor(s), control unit(s) or data acquisition system shall be as specified (see 7.2). 3.2 Standard commercial product. The monitoring device
11、s and data acquisition systems shall, as a minimum, be in accordance with the requirements of this CID and shall be the manufacturers standard commercial product. Additional or better features which are not specifically prohibited by this CID but which are a part of the manufacturers standard commer
12、cial product, shall be included in the monitoring devices and data acquisition systems being furnished. A standard commercial product is a product which has been sold or is being currently offered for sale on the commercial market through advertisements or manufacturers catalogs or brochures, and re
13、presents the latest production model. 3.3 Interface. A monitoring device specified for one location shall be compatible with same make monitoring devices of other types at that location. When specified (see 7.2), the monitoring device shall interface with existing equipment. The makes, models, and t
14、ypes of existing monitoring devices shall be specified (see 7.2). 3.4 Emission monitoring devices. 3.4.1 Type I, opacity monitor. The type I opacity monitor when used in conjunction with a data acquisition system, shall as a system, conform to the requirements of 40 CFR part 60, appendix B, performa
15、nce specification 1. The system shall be tailored to perform as specified herein. 3.4.1.1 Control unit light display. The control unit shall provide a minimum of “clear,” “warning,” and “violation” display lights. Independent controls shall be provided for adjusting 2 Licensed by Information Handlin
16、g ServicesA-A-50566 9018054 0000327 5b3 W A-A-50566 warning and violation light activation from O to 100 percent opacity and O- to 90-second delay to prevent momentary false alarms. 3.4.1.2 Control unit meter display. The control unit meter display shall be analog or digital unless one type is speci
17、fied (see 7.2). If analog display is used, it shall conform to the requirements of ANSI C39.1. The scale shall be graduated linearly from O to 100 percent opacity in 2 percent increments. Ea digital display is used, it shall conform to the requirements of ANSI C39.6. The numerals shall indicate the
18、percent opacity from O to 100 percent in percent increments. The numerals shall be distinguishable at a distance of not less than 6 feet (1.82 metre). The meters shall be accurate within I2 percent of full scale. 3.4.1.3 Relay contacts. The relay contacts shall be single-pole, single throw hermetica
19、lly sealed contacts, not less than 5 amperes, 120-volt, 60 Hertz shall be provided for the visual warning signals and when specified (see 7.2), audible warning signals. The system shall warn of filter blockage, blower motor failure, window soilage, failure in the opacity monitor, and when opacity li
20、mits are exceeded. 3.4.1.4 Analog outputs. The control unit (monitor) shall provide 4-20 milliampere outputs suitable for driving type VI data monitors. 3.4.1.5 Stack mounted equipment. The stack mounted equipment, used in conjunction with the monitoring devices shall perform the measurements in sit
21、u without any sample extraction or conditioning. Stack mounted equipment shall be equipped with an air purge system providing filtered, moisture/oil free air for minimizing the amount of dirt and dust on the optical windows. Continuous long term sealed protection shall be provided for optical lenses
22、 or reflective surfaces which could be damaged or rendered ineffective due to exposure to the stack gas stream in the event of air purge system failure. When specified (see 7.2), opacity monitors shall have provisions to automatically switch to a stand-by air supply (plant air), in the event of air
23、purge system failure, and the system shall continue to monitor opacity. The air purge system shall be equipped with easily replaceable filters. The maximum stack pressure for the air purge system shall be as specified (see 7.2). Outdoor mounted systems shall be protected from the elements and inclem
24、ent weather by NEMA 250, type 4, completely sealed weather covers. The light source shall have not less than 20,000 hours of in-use life. 3.4.1.6 Mounting hardware. Adjustable adapter flanges, thermal insulating blocks, and mounting hardware shall be included for simple, precise optical alignment. 3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA505661998MONITORINGDEVICESEMISSIONSTACKRELATEDSUPERSEDEDNAVYMILM29190ACANCNOTICE2NAVYMILM29190AVALIDNOTICE1NAVYMILM29190ANAVYMILM291901PDF

链接地址:http://www.mydoc123.com/p-976290.html