NAVY A-A-50555-1996 PUMPING UNITS SEWAGE DUPLEX CENTIRFUGAL AUTOMATIC WET-PIT TYPE [Superseded NAVY MIL-P-21251 E CANC NOTICE 1 NAVY MIL-P-21251 E NAVY MIL-P-21251 D NAVY MIL-P-212B N.pdf
《NAVY A-A-50555-1996 PUMPING UNITS SEWAGE DUPLEX CENTIRFUGAL AUTOMATIC WET-PIT TYPE [Superseded NAVY MIL-P-21251 E CANC NOTICE 1 NAVY MIL-P-21251 E NAVY MIL-P-21251 D NAVY MIL-P-212B N.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-50555-1996 PUMPING UNITS SEWAGE DUPLEX CENTIRFUGAL AUTOMATIC WET-PIT TYPE [Superseded NAVY MIL-P-21251 E CANC NOTICE 1 NAVY MIL-P-21251 E NAVY MIL-P-21251 D NAVY MIL-P-212B N.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、A-A-50555 W 9999974 0372775 192 INCH-POUND A-A-50555 December 5,1996 SUPERSEDING 31 January, 1991 MIL-P-21251 COMMERCIAL, ITEM DESCRIPTION PUMPING UNITS, SEWAGE, DUPLEX, CENTRIFUGAL, AUTOMATIC WET-PIT TYPE The General Services Administration has authorized the use of this commercial item description
2、, for all federal agencies. 1. SCOPE. This commercial item description covers automatic, electric-motor-driven, duplex, centrifugal, wet-pit type, sewage pumps. Capacities for each pump of the duplex unit range from 50 to 1,500 gallons per minute (gpm) (3.15 to 94.62 litershec); total dynamic heads
3、range from 10 to 90 feet (3 048 to 27 432 mm). This commercial item description covers pumps intended for use in pumping raw sewage that carries solids fiom a sump tank or tank into a sewer at a higher level. 2. CLASSIFICATION. The unit shall be of two types with capacities as specified herein (see
4、7.2). Type I - Column type Type II - Submerged type 3. SALIENT CHARACTERISTICS. 3.1 Descriution. 3.1.1 Column type. The pumping unit shall consist of two individual, vertical, submerged-type, nonclogging sewage pumps supported fiom motor by extended discharge column and pump shaft. Each pump shall b
5、e furnished with a vertical electric motor, pump-mounting plate, pump support pipe, discharge pipe, lubrication system, and automatic controls and if specified (see 7.2), a sump tank. Options are included in this commercial item description to provide for indoor Beneficial comments, recommendations,
6、 additions, deletions, clarifications, etc. and any data which may improve this document should be sent to: Commanding Officer (Code 1581), Naval Construction Battalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301, AMSC N/A FSC 4630 DISTRIBUTION STATEMENT A. Approved for public release; dis
7、tribution is unlimited. Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50555 9999974 0372976 O29 A-A-505 55 installation of the pumping units and for outside installation where water-tight enclosures for
8、electrical equipment are required. 3.1.2 Submerged type. The pumping unit shall consist of two individual, vertical, submerged-type, nonclogging sewage pumps. Each pump shall be close coupled with a submersible pump motor, discharge pipe, two vertical guide rails, lubrication system, and automatic c
9、ontrols and if specified (see 7.2), a sump tank. Options are included in this commercial item description to provide for indoor installation of the pumping units and for outside installation where water-tight enclosures for electrical equipment are required. 3.2 Standard commercial product. The sewa
10、ge pump shall, as a minimum, be in accordance with the requirements of this commercial item description and shall be the manufacturers standard commercial product. Additional or better features which are not specifically prohibited by this commercial item description but which are a part of the manu
11、facturers standard commercial product, shall be included in the sewage pumps being furnished. A standard commercial product is a product which has been sold or is being currently offered for sale on the commercial market through advertisements or manufacturers catalogs, or brochures, and represents
12、the latest production model. 3.3 Design. Pump units and accessories shall be designed to adequately operate and perform to the parameters listed herein. 3.4 Construction. The plan dimensions of the sump cover plate and the length of the pump fi-om the sump cover plate to the bottom of the pump secti
13、on inlet shall be specified (see 7.2) by the requirements of the procuring activity. These requirements may be indicated in the invitation for bids by any one of the following options: a. b. C. Depth and plan dimensions of Government-furnished sump, for which pump is intended, as specified (see 7.2)
14、. The manufacturers standard sump tank is to be furnished with dimensions of pump and tank to be in accordance with manufacturers recommendations for the specified operating characteristics of the pump. If a sump tank is to be furnished, dimensions of the tank are to be as specified (see 7.2), by th
15、e procuring activity. In the event the length of pump is by (a) or (c), the dimensions of the pump from the sump cover plate to the bottom of the suction inlet shall be such as to provide a clearance of not less than one discharge pipe diameter nor more than 18 inches (457 mm) from the floor of the
16、sump or sump tank. 3.4.1 Pump casing. The volute and discharge nozzle of the type I pump casing shall be cast in one piece and shall be designed to permit inspection and removal of the impeller. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5
17、 055 5 .I 3.4.2 Impeller. Unless otherwise specified (see 7.2), the impeller shall be of the totally enclosed type. 3.4.3 Shaft. Pump shafts for type I units shall be high carbon or alloy steel, unless otherwise specified (see 7.2). 3.4.4 Discharge pipe. A discharge pipe running from the pump discha
18、rge outlet through the sump cover plate shall be funiished as an integral part of the pumping unit. The discharge pipe shall be gastight through the sump cover plate. Unless otherwise specified (see 7.2), the discharge end of the pipe shall terminate in a screwed or flanged connection in accordance
19、with the manufacturers standard practice. 3.4.5 Sump cover plate. If specified (see 7.2), a threaded outlet shall be provided to permit installation of a vent pipe. 3.4.6 Coupling. The coupling shall be of adequate type and size to efficiently transfer load from motor to shaft. 3.4.7 Paint schedule.
20、 Surface preparation and painting shall be as recommended by manufacturer. 3.4.8 Automatic discharge connection (type II only). Each pump shall be hished with a submersible discharge connection system to permit removal and installation of the pump without the necessity of an operator entering the we
21、t well. The design must insure an automatic and firm connection of the pump to the discharge piping when lowered into place. 3.5 Performance. 3.5.1 Capacity. Each pump of the duplex pumping unit shall deliver, at rated speed, not less than the specified (see 7.2) gpm against the specified (see 7.2)
22、dynamic heads, while the liquid level is not more than 1 foot above the datum elevation of the pump. Each pump will handle solids to 3 inches (76 mm), or as specified (see 7.2). Definitions will be to the Hydraulic Institute Standards. 3.6 ComDonents and accessories. 3.6.1 Electric motors. Electric
23、motors for type I shall be of the vertical type and shall be rated and constructed in accordance with the applicable provisions of NEMA MG 1. Motors shall be furnished with drip-proof or NEMA type II, weather-protected enclosures as specified (see 7.2). Voltage, phase, and frequency ratings shall be
24、 as specified (see 7.2). Electrical motors for type II shall conform to NEMA design Class By and incorporate Class F insulation materials to withstand a continuous operating temperature of 31 1 degrees Fahrenheit (“ F) (1 55 degrees Celsius (“ C). The pump and motor shall be capable of handling liqu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA505551996PUMPINGUNITSSEWAGEDUPLEXCENTIRFUGALAUTOMATICWETPITTYPESUPERSEDEDNAVYMILP21251ECANCNOTICE1NAVYMILP21251ENAVYMILP21251DNAVYMILP212BNPDF

链接地址:http://www.mydoc123.com/p-976288.html