1、I NOT MEASUREMENT I I SENSITIVE I A-A- 50548 June 9, 1995 SUPERSEDING 23 August 1990 MIL-F-16716E COMMERCIAL ITEM DESCRIPTION FANS, CENTRIFUGAL, INDUSTRIAL The General Services Administration has authorized the use of this Commercial Item Description for all federal agencies. 1. SCOPE. This specific
2、ation covers electric-motor-driven centrifugal fans which are designed for ventilating uses and industrial air-handling applications. 2. CLASSIFICATION. The fans are of the following types, as specified (see 7.2). Type I - Forward-curved blades. Type II - Radial blades. Type III - Backward-inclined
3、blades. 3. SALIENT CHARACTERISTICS. 3.1 DescriPtion. The unit shall consist of a centrifugal fan, electric motor, guards, and accessories. All components shall be attached to a common base which shall include provisions for fastening it to a foundation. The unit shall be completely assembled, ready
4、for installation, 3.2 Standards compliance. Fans shall be capacity rated in accordance with AMCA 210 and sound rated in accordance with AMCA 300, prior to approval of the first article, if one is specified, or prior to approval of the first shipment, if a first article is not specified. The supplier
5、 shall submit to the contracting officer satisfactory evidence that the fan he proposes to furnish has been rated in accordance with AMCA 210 and AMCA 300. IBeneficial comments, recommendations, additions, deletions, clarifications, I letc. and any pertinent data which may be of use in improving thi
6、s document I Ishould be addressed to: Commanding Officer (Code 156), Naval Construction I IBattalion Center, 1000 23rd Avenue, Port Hueneme, CA 93043-4301, by using I Ithe Standardization Document Improvement Proposal (DD Form 1426) appearing at Ithe end of this document or bv letter. I AMSC N/A FSC
7、 4140 DISTRIBUTION STATEMENT A. Approved for public release, distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50548 D 9999974 OLb89L8 T72 4 + A-A- 50548 3.3 Desien. The fan assembly shall be designed to handle clean or d
8、ust-laden air at temperatures up to 250 degrees Fahrenheit (OF) (121 degrees Celsius (OC), and up to 600F (316OC) when equipped with a bearing cooling device (see 3.6.3.1). The design of the equipment and accessories shall permit accessibility for maintenance and service in the field. The design sha
9、ll be such as to prevent conditions hazardous to personnel or deleterious to equipment. The fan assembly shall be built in accordance with AMCA 99. 3.4 Safety. All parts which are energized electrically shall be insulated, fully enclosed, or guarded when such parts are exposed to contact by personne
10、l or otherwise create a hazard. All moving parts hazardous to personnel shall be enclosed or guarded. Nonfunctional sharp edges, projecting points, and excessive length of fastening devices shall be avoided. Protective devices shall be mounted on or near components containing hidden hazards. portion
11、s of OSHA Title 29, CFR, Part 1910.219 shall apply. Applicable 3.5 Performance. The fan shall deliver its rated capacity in cubic feet per minute at the static pressure in inches of water specified (see 7.2) with tolerances set forth in AMCA 210. Fan sound power level shall not exceed 90 decibels, A
12、-weighted scale, continuous or intermittent, at five feet from the equipment. 3.6 Details of components. The unit shall consist of the components specified below; and when the motor is connected to the matching power source, the unit shall function in accordance with the performance requirements. 3.
13、6.1 Fan wheel. Unless otherwise specified (see 7.2), the fan wheel shall be constructed of cast aluminum alloy or carbon steel plate, as specified (see 7.2). Each steel blade shall be riveted or welded to form the fan wheel. 3.6.2 Fan shaft, Unless otherwise specified (see 7.2), the shaft shall be t
14、urned, ground, and polished carbon steel alloy. The maximum allowable turnout after all machining shall be 0.001 inch (0.0254 millimeters (nun) on shafts with diameter less than or equal to 1.5 inches (38.1 nun) in diameter and 0.002 inches (0.05 mm) on shafts greater than 1.5 inches (38.1 nun) in d
15、iameter. The shaft shall be sized for maximum speed of the size of fan involved and shall operate at not more than 80 percent of the first critical speed. 3.6.3 Fan bearings. Unless otherwise specified (see 7.2), the fan shall be equipped with precision anti-friction bearings with an average life of
16、 B-10. The bearings shall be of the self-alining type and shall be mounted in suitable pillow blocks having provision for attachment to the fan housing or base assembly. 3.6.3.1 Bearing cooling device. When specified (see 7.2), a bearing cooling fan of suitable size, of split design, or a heat sling
17、er shall be provided with anti-friction bearing when the air temperature in the fan is greater than 250F (121OC) but less than 600F (316OC). 3.6.4 Fan housing. sheet and of a nominal thickness not less than that listed in table I. The scroll and side plate joints shall be made airtight. The housing
18、shall be reinforced to minimize vibration. When specified (see 7.2). the discharge direction for types I and III larger than 33 inches in fan diameter, and type II The housing shall be constructed of carbon steel plate or 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without
19、 license from IHS-,-,- _ A-A-50548 A-A-50548 9999974 OLb89L 909 larger than 57 inches (1448 mm) in fan diameter shall be easily converted at angles of 45 degrees. When specified (see 7.2), a threaded drain connection to accommodate a 1 inch (25.4 mm) or 3/4-inch (19.1 mm) diameter standard pipe, as
20、specified (see 7.2). Standard pipe shall be located at the lowest point in the scroll. When specified (see 7.2), a flush type access door shall be installed on the fan scroll and held by quick-release clamps on type II fans. Inlet and outlet duct connections shall be flanged. TABLE I. Housine eaees.
21、 Nominal fan diameter I I (inches) I Sides and Scroll I I I I 16 gage I I I I 16 (406 mm) up to 24 (610 mm) I 14 gage I I 24 (610 mm) up to 72 (1829 mm) I 12 gage I I 72 (1829 mm) up to 132 (3353 mm)I 10 gage I I 12 (305 mm) up to 16 (406 mm) I 3.6.5 Motor. The motor shall conform to NEMA MG 1, and
22、shall be capable of continuous operation when driving the fan at rated conditions, and may be single or multi-speed, unless one of these is definitely specified (see 7.2). Features of bearings, enclosure, and electrical characteristics shall be as specified (see 7.2). When specified (see 7.2), an ac
23、ross-the-line part-wind wye-delta or autotransformer shall be supplied. When specified (see 7.2), the motor shall be open drip proof, totally enclosed, or explosion proof. 3.6.5.1 Direct drive. When a direct drive is specified (see 7.2), the fan wheel shall be mounted on the motor shaft or driven th
24、rough a suitable coupling by the motor. The motor shall be aligned to minimize drive line vibration. When specified (see 7.2), the assembly shall be mounted on resilient vibration isolators. 3.6.5.2 V-belt drive. V-belts. the motor horsepower rating corrected to the service and arc-of-contact factor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA505481995FANSCENTRIFUGALINDUSTRIAL 工业 离心 风扇 PDF

链接地址:http://www.mydoc123.com/p-976287.html