MSS SP-105-2010 Instrument Valves for Code Applications《仪表阀代码申请》.pdf
《MSS SP-105-2010 Instrument Valves for Code Applications《仪表阀代码申请》.pdf》由会员分享,可在线阅读,更多相关《MSS SP-105-2010 Instrument Valves for Code Applications《仪表阀代码申请》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 MSS SP-105-2010 Instrument Valves for Code Applications Standard Practice Developed and Approved by the Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. 127 Park Street, NE Vienna, Virginia 22180 Phone: (703) 281-6613 Fax: (703) 281-6671 e-mail: infomss-hq.org www.mss-
2、hq.org MSS STANDARD PRACTICE SP-105i This MSS Standard Practice was developed under the consensus of the MSS Technical Committee 115 and the MSS Coordinating Committee. The content of this Standard Practice is the result of the efforts of competent and concerned volunteers to provide an effective, c
3、lear, and non-exclusive specification that will benefit the industry as a whole. This MSS Standard Practice is intended as a basis for common practice by the manufacturer, the user, and the general public. The existence of an MSS Standard Practice does not in itself preclude the manufacture, sale, o
4、r use of products not conforming to the Standard Practice. Mandatory conformance is established only by reference in a code, specification, sales contract, or public law, as applicable. “Unless otherwise specifically noted in this MSS Standard Practice, other standards referred to herein are identif
5、ied by the date of issue that was applicable to this Standard Practice at the date of issue of this Standard Practice. See Annex A. This Standard Practice shall remain silent on the applicability of those other standards of prior or subsequent dates of issue even though applicable provisions may not
6、 have changed. References contained herein which are bibliographic in nature are noted as supplemental in the text.” Substantive changes in this 2010 edition are “flagged” by parallel bars as shown on the margins of this paragraph. The specific detail of the change may be determined by comparing the
7、 material flagged with that in the previous edition. Any part of this Standard Practice may be quoted. Credit lines should read Extracted from MSS SP-105-2010 with permission of the publisher, Manufacturers Standardization Society of the Valves and Fittings Industry, Inc. Reproduction is prohibited
8、under copyright convention unless written permission is granted by Manufacturers Standardization Society of the Valve and Fittings Industry Inc. Originally Approved: July 1990 Originally Published: October 1990 Current Edition Approved: May 2010 Current Edition Published: September 2010 Copyright ,
9、1990, 1996, 2010 by Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. Printed in U.S.A. MSS STANDARD PRACTICE SP-105ii TABLE OF CONTENTS SECTION PAGE 1 SCOPE . 1 2 DEFINITIONS 1 3 MATERIALS 1 4 DESIGN REQUIREMENTS . 2 5 QUALIFICATION 3 6 ACCEPTANCE TESTING . 5 7 MARKING
10、5 FIGURE 1 Direct Mounted Instrument Manifold Gasket Groove and Flange Details 4 ANNEX A Referenced Standards and Applicable Dates . 6 MSS STANDARD PRACTICE SP-1051 1. SCOPE 1.1 This Standard Practice applies to small valves and manifold valves developed for and predominately used in instrument, con
11、trol, and sampling piping systems. It covers steel and alloy valves of nominal pipe size (NPS) 1 and smaller, and pressure ratings of 15,000 psi and lower at 100F. 1.2 This Standard Practice applies to instrument valve designs including, but not limited to, needle valves, packless valves, ball valve
12、s, plug valves, check valves and manifold valves. Instrument valves are generally of proprietary design; this Standard Practice is not intended to define or limit designs, construction, performance, envelope dimensions, or valve types. 1.3 The application of valve type, size, rating, materials of co
13、nstruction, and suitability for the service are the responsibility of the purchaser and are outside the scope of this Standard Practice. 2. DEFINITIONS 2.1 General Definitions given in MSS SP-96 apply to this Standard Practice. 2.2 Instrument Valves Valves designed for use in instrument, control, an
14、d sampling piping systems, (e.g., see ASME B31.1, Article 122.3). 2.3 Instrument Piping Piping used to connect instruments to main piping or other instruments. 2.4 Control Piping Piping used to interconnect pneumatically or hydraulically operated control apparatuses, or to signal control systems. 2.
15、5 Sampling Piping Piping used for the collection of samples (such as steam, water, oil, gas, and chemicals) from process systems. 2.6 Manifold Valve Two or more instrument valves fabricated into a single valve body. 2.7 Cold Working Pressure Rating The maximum allowable working pressure of a valve a
16、t ambient conditions (-20F to 100F), abbreviated CWP. 2.8 Pressure Boundary Parts The following items are defined to be pressure boundary parts. Each item may not apply to all valve designs. a) Body b) Bonnet c) Union Nut d) Body to Bonnet Bolting e) Body Bolting 2.9 Packless Valve A valve with a di
17、aphragm or bellows stem seal instead of a packing or O-ring seal at the stem. 3. MATERIALS 3.1 General The pressure boundary parts of the valve shall be made of the materials specified herein. 3.2. Non-pressure boundary parts (such as the stem, glands, packing nut) shall be made of materials compati
18、ble with the pressure boundary parts materials. For compression packing systems, see MSS SP-132. 3.3 The following materials are acceptable for use as pressure boundary parts. a) Materials listed in ASME B16.34 b) Materials listed in ASME B31.1 c) Materials listed in ASME B31.3 d) Materials listed i
19、n ASME Boiler and Pressure Vessel Code, Section III e) Materials listed in ASME B31.12 INSTRUMENT VALVES FOR CODE APPLICATIONS MSS STANDARD PRACTICE SP-1052 3.4 Certified material test reports shall be obtained for pressure boundary parts materials. Certifications shall include chemical analysis and
20、 mechanical properties. 4. DESIGN REQUIREMENTS 4.1 Valves designed in accordance with this Standard Practice shall have their working pressure established by calculation, hydrostatic proof and burst tests or both as specified in Section 5. 4.1.1 Qualification of valves designed to Section 4.1 shall
21、be conducted on each design and size of valve to establish the CWP rating. 4.1.2 The CWP rating of valves of identical design and size but made of different materials shall be proportional to the allowable stress of each material or may be determined by hydrostatic qualification tests on valves made
22、 of each material, at the manufacturers option. 4.1.3 The CWP rating of valves of identical design and size but with different end connections shall be determined by the rating of the valve or the end connection, whichever is less. 4.1.4 The CWP rating of a valve design may be established by the man
23、ufacturer at a value lower than the rating allowed by the qualification tests of Section 5. In that case the lower pressure rating may be established for a valve design and size, regardless of materials or end connections. Such reduced ratings are usually dictated by performance limitations such as
24、operating torque, cycle life, or non-metallic component limitations. 4.1.5 Packing nut adjustment may be necessary to compensate for temperature change. 4.1.6 The manufacturer shall provide pressure ratings for temperatures above 100F. This temperature is the temperature of the pressure containing s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- MSSSP1052010INSTRUMENTVALVESFORCODEAPPLICATIONS 仪表 代码 申请 PDF

链接地址:http://www.mydoc123.com/p-822932.html