ITU-T O 132-1988 QUANTIZING DISTORTION MEASURING EQUIPMENT USING A SINUSOIDAL TEST SIGNAL《量化失真测量设备用正弦测试信号-规格为测量设备(第4研究组)共3页》.pdf
《ITU-T O 132-1988 QUANTIZING DISTORTION MEASURING EQUIPMENT USING A SINUSOIDAL TEST SIGNAL《量化失真测量设备用正弦测试信号-规格为测量设备(第4研究组)共3页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 132-1988 QUANTIZING DISTORTION MEASURING EQUIPMENT USING A SINUSOIDAL TEST SIGNAL《量化失真测量设备用正弦测试信号-规格为测量设备(第4研究组)共3页》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#) amended at Melbourne, 1988)1 IntroductionThis specification gives basic clauses describing the essential features to be provided in test equipment using asinusoidal test signal for quantizing distortion
2、 measurements on PCM channels. It is important that the characteristics ofquantizing distortion measuring apparatus of this type are sufficiently specified to ensure that they are capable ofinterworking and that they will give results of sufficient accuracy. This specification is based on a general
3、statement ofthe method described as Method 2 in 9 of Recommendation G.712 1.2 Testing methodThe testing method consists of applying a sine-wave signal to the input port of a PCM channel and measuringthe ratio of the received signal to distortion power, using the proper noise weighting (see 3.3.4 bel
4、ow). The methodalso requires the use of a narrow-band rejection filter in the receiver equipment to block the sinusoidal test signal fromthe distortion measuring circuits so that the distortion power may be measured.3 Specifications3.1 Test signal frequenciesA test signal in either of two frequency
5、bands may be required depending on the test-signal rejection filterbeing used to make the measurement. The preferred test frequencies are either 820 Hz or 1020 Hz. However, otherfrequencies in the rejection band of the test-signal rejection filter (such as 804 Hz or 850 Hz) may be used.3.2 Character
6、istics of the signal source3.2.1 Signal level rangeAt least 45 to + 5 dBm0 for relative levels according to 11 of Recommendation G.232 2 with a settingaccuracy of 0.2 dB.3.2.2 Output impedance (frequency range 300 Hz to 4 kHz) Balanced, earth free (other impedances optional) 600 ohms Return loss . 3
7、0 dB Output signal balance. 40 dB3.2.3 Distortion and spurious modulation ratio 50 dB3.2.4 Frequency accuracy and stabilityThe accuracy and stability of the test signal frequency shall be appropriate to the frequency used and itsposition with respect to the rejection band of the filter concerned. Th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO1321988QUANTIZINGDISTORTIONMEASURINGEQUIPMENTUSINGASINUSOIDALTESTSIGNAL 量化 失真 测量 备用 正弦 测试 信号 规格

链接地址:http://www.mydoc123.com/p-800358.html