《ITU-T O 131-1988 QUANTIZING DISTORTION MEASURING EQUIPMENT USING A PSEUDO-RANDOM NOISE TEST SIGNAL《量化失真测量设备采用伪随机噪声测试信号-规格为测量设备(第4研究组)共6页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 131-1988 QUANTIZING DISTORTION MEASURING EQUIPMENT USING A PSEUDO-RANDOM NOISE TEST SIGNAL《量化失真测量设备采用伪随机噪声测试信号-规格为测量设备(第4研究组)共6页》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#) amended at Geneva, 1980, and at Melbourne, 1988)1 PreambleIt is important that the characteristics of quantizing distortion measuring apparatus are specified with sufficientprecision to ensure that all
2、future designs of measuring apparatus conforming to the recommended specification shall becompatible with one another, i.e., they shall be capable of interworking and give results of specified accuracy withoutthe need for any special procedures or corrections to the measurements results. It is consi
3、dered equally important that alldesigns of measuring apparatus conforming to the recommended specification shall be capable of interworking withexisting designs of measuring apparatus already in use by various Administrations, who will thus not be placed at anyeconomic disadvantage. The following sp
4、ecification is based on the proposals studied by Study Group XVIII and isspecifically aimed at the foregoing compatibility objectives.Note The question of interworking between existing designs of quantizing distortion measuring apparatus isnot, in itself, directly relevant to this specification, but
5、 it is worth recording that this topic has been studied by theFederal Republic of Germany and the United Kingdom Post Office. Satisfactory rules have been established to facilitateinterworking between the different existing types of measuring apparatus which use a band-limited pseudo-random noisesou
6、rce.2 Testing method proposedThe method proposed is that described in Method 1 in 9 of Recommendation G.712 1. The proposed noisesource is band-limited pseudo-random noise having a probability density distribution of amplitudes which issubstantially near to a Gaussian distribution1).The signal-to-to
7、tal distortion power, including quantizing distortion, is measured as the ratio of the power ofreceived stimulus in the reference band, to the noise power in the measured band. A correction is included to relate themeasurement to the full PCM speech channel bandwidth._1)The receive measuring apparat
8、us specified in 3.2 may also be used to measure quantizing distortion using a sinusoidal test signalin the frequency range 350-550 Hz (preferably at 420 20 Hz) instead of the pseudo-random noise stimulus. It should be noted,however, that while the measurement is similar to Method 2 described in Reco
9、mmendation G.712 1, the obtained measurementresults are related to a bandwidth of 3.1 kHz and that no noise weighting is provided. It should also be noted that results given bythe pseudo-random noise and sinusoidal methods may not be the same.2 Fascicle IV.4 - Rec. O.131The principle of the measurem
10、ent is illustrated in Figure 1/O.131.d01-scFIGURE 1/O.131.D013 Basic specification clauses3.1 SendThe sending signal is a band-limited pseudo-random noise having the following characteristics:3.1.1 Band limited noise stimulusApproximately Gaussian distribution of the amplitudes within the bandwidth
11、of the send filter. The bandwidthcan have any value from 100 Hz to 200 Hz between the 3-dB points (see 3.1.4 and 3.1.5 below).3.1.2 Number of spectral linesNot less than 25 spectral lines with a spacing not greater than 8 Hz measured at the output of the send filter.3.1.3 Peak-to-r.m.s. ratio10.5 dB
12、. Tolerance 0.5 dB.Note 1 The requirements according to 3.1.1 to 3.1.3 above may be accomplished by a noise stimulusderived from the output of a 17-stage shift register with exclusive OR gating with the outputs of stages 3 and 17 returnedto the input of stage 1. The shift register produces a maximal
13、ly long sequence of (217 1) bits.The shift register is driven at a clock frequency fcHz such that the spectral line spacing fsHz of the outputsignal is less than or equal to 8 Hz.In order to meet the specified limits of the peak-to-r.m.s. ratio of the sent signal as given in 3.1.3 above, theclock fr
14、equency can be adjusted to:fc= fs(217 1) HzTo keep the peak factor within the specified limits, a stability of the clock frequency fcon the order of 1% isrequired.Fascicle IV.4 - Rec. O.131 3Note 2 Instead of using a shift register to generate the noise signal, other principles may be adopted as lon
15、gas the generated signal has the characteristics recommended in 3.1.1 and 3.1.3 above.3.1.4 Frequency position of sent signalBetween 350 and 550 Hz.3.1.5 Sending filter characteristicsThe attenuation of the bandpass filter with reference to minimum attenuations should be as follows:not lower than 35
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO1311988QUANTIZINGDISTORTIONMEASURINGEQUIPMENTUSINGAPSEUDORANDOMNOISETESTSIGNAL 量化 失真 测量 设备 采用 随机

链接地址:http://www.mydoc123.com/p-800355.html