1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 - TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU-!).4%.!.#%G0 ).42/$5#4)/.G0G0!.$G0G0%.%2!,G0G002).#)0,%334!“),)49G0G0/b) the design of carrier generators with a view to great reliability;c) the design of power supplies; attention is particularly drawn to
2、the importance of the judicious choice andgrading of protective devices (fuses, circuit-breakers) in the power feeds to repeater station racks.Note See in this connection Recommendation G.231 2.5.3 Care in the organization of work in international exchanges, repeater stations, and on the transmissio
3、n lines,cables and systems used in the international networkExperience has shown that operations carried out on exchange and repeater station equipment and on theexternal plants (underground cables, etc.) are a major cause of attenuation and phase variations and of interruptions toservice in the int
4、ernational network.All work liable to cause interference should therefore be carried out, when possible, at times of light traffic. Itmust be recognized that for very long routes it will become increasingly difficult to find suitable periods of light traffic,bearing in mind the time differences whic
5、h will exist between the terminal countries on such routes. This will requiregood coordination and cooperation between Administrations. In particular, the control stations should be consulted wellin advance (see Recommendation M.490).5.4 Care in the organization of maintenanceThe same reasons for tr
6、ansferring working operations to times of light traffic apply to maintenance operations.It is desirable to avoid all equipment changeovers which are not absolutely necessary.It is also desirable to guard against maintenance operations which appear harmless but which may, however,result in short inte
7、rruptions and which are all the more dangerous if they affect common units (e.g. changeover of masteroscillators).5.5 Power supplies5.5.1 Too frequent changeover of power supplies for routine maintenance must be avoided. It should be possible tomake partial tests to check that the standby motor-gene
8、rator starts, without changing over the power supplies.5.5.2 The instruction or training of staff during the day on working power supplies should be forbidden.5.5.3 Changeover of power supplies should be carried out at times of light traffic and as far as possible at night.Fascicle IV.1 - Rec. M.160
9、 35.5.4 To ensure that circuits in the international network are not interrupted owing to the failure of public powersupplies, repeater stations in the international network should have power-continuity arrangements which ensure that thetransmission equipment continues to operate, without any interr
10、uption, in the event of a failure of the public powersupply.5.6 Care in the testing of new equipmentEquipment should not be put into service until after the most thorough inspection. It is necessary to ensure thatthe pressing needs of the operating services do not result in these tests being omitted
11、 or hastily done.Where the urgent requirements of the operating services resulted in equipment being put into service before ithad been sufficiently tested, the equipment should be temporarily taken out of service and a thorough inspection made assoon as possible.5.7 Vibration testingVibration tests
12、, using the principles described in 3, help in improving transmission stability and in ensuringsatisfactory operation of transmission equipment. They should be made, wherever applicable, when new equipment isput into service, under special circumstances for fault locating purposes or even as a routi
13、ne measure for preventivemaintenance, if the Administration concerned deems it necessary.5.8 Automatic regulation by pilots (group pilots, supergroup pilots, etc.)In carrier systems, the presence of pilots (line pilots, group pilots, supergroup pilots, etc.) makes it possible tosupervise transmissio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTM1601988STABILITYOFTRANSMISSION 传输 稳定 PDF

链接地址:http://www.mydoc123.com/p-799761.html