ITU-T K 29-1992 Coordinated protection schemes for telecommunication cables below ground (Study Group V)《地下通信电缆、光缆的综合保护方案-抗干扰防护(研究组5)7页》.pdf
《ITU-T K 29-1992 Coordinated protection schemes for telecommunication cables below ground (Study Group V)《地下通信电缆、光缆的综合保护方案-抗干扰防护(研究组5)7页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T K 29-1992 Coordinated protection schemes for telecommunication cables below ground (Study Group V)《地下通信电缆、光缆的综合保护方案-抗干扰防护(研究组5)7页》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION#)44 + THE INTERNATIONALTELEGRAPH AND TELEPHONECONSULTATIVE COMMITTEE02/4%#4)/.G0G0!).34G0G0).4%2b) protection against effects of electric power and traction lines: soil resistivity (in deep layers), inducing current, distance between the telecommunication cable
2、and the electric power and traction line;c) protection against corrosion: soil resistivity (in the top layer), corrosive components (ions) in the soil, stray currents in the soil (sources of d.c. stray currents are d.c. traction rails, earthing electrodesassociated with d.c. sources, metallic struct
3、ures with cathodic protection and the like).Protection of underground communication cables against corrosion is achieved mainly with protective plasticcoverings on the metal cable sheath.Regarding the environment, the installed cable behaviour is different if an insulating or conductive plasticmater
4、ial is used as protective covering. Therefore, coordinated protection schemes are also different and the two casesshould be considered separately.2 Coordinated protection with insulating plastic coverings2.1 Metallic cablesCoordinated protection of telecommunication metallic cables, i.e. cables with
5、 metal conductors (symmetricalor coaxial pairs), against induction, lightning and corrosion with insulating plastic coverings requires the considerationof: suitable metal sheath; adequate covering with adequate dielectric strength;2 Recommendation K.29 earth connections of the metal sheath; use of a
6、 shield wire. The manual “The protection of telecommunication lines and equipment againstlightning discharges” contains useful information for determining the need for shield wires.If an Administration has positive experience with respect to corrosion, then periodic inspection of theinsulating cover
7、ing is not necessary. In areas where stray currents exist or corrosion due to interference currents has beenobserved, periodic inspection may be recommended.The distance, d between earthing electrodes and their resistance, R can be established on the basis of: the specific calculation methods, takin
8、g into account the limit values for the voltage between any metalcomponents and earth due to induction from power and traction lines (ref. “Directives concerning theprotection of telecommunication lines against harmful effects from electric power and electrified railwaylines”); the transfer impedanc
9、e of telecommunication cables; the thunderstorm activity, i.e. number of thunderstorm days per year or ground flash density.Nevertheless, the following indications about the values of d and R can be taken into account: local cables are usually earthed only at the ends; for extended cable installatio
10、ns it is recommended toearth the cables additionally at intermediate points; long-distance cables are earthed at the repeater stations or additionally at intermediate locations.Multipoint sacrificial anodes may be considered as earth electrodes; in such cases, the earth resistance valueshave to be c
11、ontrolled during their lifetime. Such a control can be recommended for normal earth electrodes.2.2 Optical fibre cables2.2.1 Metal-free cablesMetal-free cables do not require protection against power induction, lightning damage and metal corrosion,although lightning damage to such cables is conceiva
12、ble when they are installed below ground in metal ducts.2.2.2 Metal components in the cable core and sheathFrom the protection point of view, this type of cable is the same as a metal cable; therefore the coordinatedprotection, described in 2.1, applies.Nevertheless, the poor shielding effect of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTK291992COORDINATEDPROTECTIONSCHEMESFORTELECOMMUNICATIONCABLESBELOWGROUNDSTUDYGROUPV 地下 通信 电缆 光缆 综合

链接地址:http://www.mydoc123.com/p-799193.html