1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW3064 Performance Validation of Automatic Climate Control Copyright 2011 General Motors Company All Rights Reserved December 2011 Originating Department: North American Engineering Standards Page 1 of 10 1 Scope Note: Nothing in this standard superce
2、des applicable laws and regulations. Note: In the event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. Validation of the performance capability of an automatic vehicle Heating, Ventilating, Air Conditioning (HVAC) system by reproducibl
3、e measurements in a climatic wind tunnel. 1.2 Foreword. Not applicable. 1.3 Applicability. For all passenger vehicles with an Air Conditioning (A/C) system. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.
4、2 GM Standards/Specifications. GMW15845 3 Resources 3.1 Facilities. 3.1.1 Climatic wind tunnel including a chassis dynamometer with adjusting possibilities for a vehicle speed of 110 km/h minimum, a wind speed of 110 km/h minimum, an ambient temperature of 35 C to +50 C minimum and a relative humidi
5、ty of 80% minimum. 3.1.2 Capability of solar radiation simulation with a power of 1100 W/m. 3.2 Equipment. 3.2.1 General. 3.2.1.1 Temperature measuring and recording equipment for at least 16 measuring points. 3.2.1.2 Pressure measuring and recording equipment for at least three (3) measuring points
6、 in the refrigerant circuit. 3.2.1.3 Measuring and recording equipment for the engine speed. 3.2.1.4 Measuring and recording equipment for voltage and current for compartment blower(s), battery(ies), and engine cooling fans (if applicable). 3.2.1.5 Device for operation and adjustment of accelerator
7、pedal. 3.2.1.6 Battery Charger to maintain battery during warmup (see 4.2.2.1.1). 3.3 Test Vehicle/Test Piece. Passenger vehicles equipped with an A/C system. 3.4 Test Time. See 4.3.1 and 4.3.2. Calendar time: Not applicable Test hours: Not applicable Coordination hours: Not applicable 3.5 Test Requ
8、ired Information. Test conditions as specified by the Vehicle Technical Specification (VTS). Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS
9、 GMW3064 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 2 of 10 3.6 Personnel/Skills. One (1) climatic tunnel operator, One (1) driver (if necessary). 4 Procedure 4.1 Preparation. The vehicle shall be prepared for the climatic tunnel per GMW15845 and shall be equipped w
10、ith devices according to 3.2 and 4.3.3. Front seat in rearmost position (manual and power actuation); seats shall be in no tilt full down position. If front seat has back rest tilt feature, place in the full upright position. 4.2 Conditions. 4.2.1 Environmental Conditions. 4.2.1.1 Ambient Temperatur
11、e. As described in the testing matrix. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates, reports, etc. 4.2.2.1 Vehicle Conditioning - Tunnel Cycle One (1). 4.2.2.1.1 War
12、mup. Wind Speed: Optional Temperature: Test temperature Engine: Off Blower: Medium Blower Condition Battery Connected to Charger Windows: Optional Air Direction: A/C Outlet Mode Sun Load: On Time: Until the temperature of the body mass (e.g., seat rail) has achieved the test temperature. 4.2.2.1.2 P
13、re-Soak. Wind Speed: 50 km/h Temperature: Test temperature Engine: On (idle) Compressor Off Blower: Medium Blower Condition Windows: Open Air Direction: A/C Outlet mode Outside Air Mode: (OSA) Sun Load: Off Time: 30 minutes 4.2.2.1.3 Soak Conditions. Wind Speed: As required to maintain test conditio
14、ns (e.g., 5 km/h) Temperature: Test temperature Engine: Off Blower: Off Windows: Closed Air Direction: A/C mode with all outlets open Recirculate mode: (P/R) Sun Load: On Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networ
15、king permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW3064 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 3 of 10 Time: Depending on the installed sun simulation equipment, the time shall be defined as the equivalent period, 50 minimum, to re
16、ach the same soak results as obtained with natural sun load of 1 h at 1000 W/m (or as specified by the corresponding VTS) at test temperature. 4.2.2.2 Vehicle Conditioning - Tunnel Cycle Two (2). 4.2.2.2.1 Soak. It shall be ensured that the entire vehicle is at a uniform temperature (vehicle mass, e
17、.g., seat rail) which is in the range of 1 K of the ambient temperature prior to start of test. The engine oil temperature shall be in the range of 1 K of the ambient temperature. 4.2.2.2.2 Warmup Conditions. Vehicle and wind speeds as specified in the measurement program (see 4.3.1). 4.2.2.3 Idle C
18、onditions. The wind speed in front of the radiator shall be 0 km/h. 4.2.2.4 Electrical Power Supply. All electrical systems are supplied by the internal vehicle power supply. The battery shall be fully charged before the test. The blower speed (voltage) is defined by the corresponding VTS. 4.2.2.5 G
19、ear Step or Drive Position. Table 1: Gear Steps or Drive Positions Transmission 40 km/h 50 km/h 60 km/h 80 km/h Idle MT4 3 4 4 4 Neutral MT5 WR Note 1 3 4 4 4 Neutral MT5 CR Note 2 3 5 5 5 Neutral AT Note 3 Note 3 Note 3 Note 3 Note 3 Note 3 Note 1: 5th Gear = Overdrive. Note 2: 5th Gear = 1:1 Gear
20、Ratio. Note 3: Highest Drive Gear. Note: The specified vehicle speeds are driven at road load (on level stretches without acceleration). Note: For repeat measurements on vehicles with automatic transmissions, it shall be ensured that same vehicle speeds are driven at the same lowest engine speeds. C
21、opyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW3064 Copyright 2011 General Motors Company All Rights Reserved December 2011 Page 4 of 10
22、4.3 Instructions. 4.3.1 Climatic Tunnel Cycle One (1). Key to Figure 1: 1 = Warmup 2 = Pre-Soak 3 = Soak 4 = OSA 5 = P/R 6 = Variable, See 4.2.2.1.1 7 = See 4.2.2.2 8 = Test Time in Minutes (min = minutes) Figure 1: Climatic Tunnel Cycle One (1) 4.3.2 Climatic Tunnel Cycle Two (2). Key to Figure 2:
23、1 = Soak 2 = Warmup 3 = Idle 4 = OSA 5 = Variable, See 4.2.2.1 6 = Time in Minutes Figure 2: Climatic Tunnel Cycle Two (2) 4.3.3 Measuring Values and Data to be Recorded. 4.3.3.1 Temperatures in Degree Celsius (C). Ambient Coolant, heater core in Coolant, heater core out Coolant, rear heater core in
24、 (if applicable) Coolant, rear heater core out (if applicable) Coolant, cylinder head or under stat Coolant, radiator out Engine oil (bottom of the oil dipstick) Refrigerant, compressor-out Refrigerant, before expansion device Copyright General Motors Company Provided by IHS under license with Gener
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW30642011PERFORMANCEVALIDATIONOFAUTOMATICCLIMATECONTROLISSUE2ENGLISH 自动 气候 控制 性能 验证 出版 英文 版本 PDF

链接地址:http://www.mydoc123.com/p-757998.html