GMKOREA EDS-T-7826-2006 TEST METHOD FOR MATERIAL ANALYSIS OF PLASTIC & RUBBER USING FTIR.pdf
《GMKOREA EDS-T-7826-2006 TEST METHOD FOR MATERIAL ANALYSIS OF PLASTIC & RUBBER USING FTIR.pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-7826-2006 TEST METHOD FOR MATERIAL ANALYSIS OF PLASTIC & RUBBER USING FTIR.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards TEST METHOD FOR MATERIAL ANALYSIS OF PLASTIC & RUBBER USING FTIR EDS-T-7826 ISSUED DATE: 1996. 05. 09 REVISED DATE: 2006. 06. 19 VERSION: 3 EDS-T-7826TEST METHOD FOR MATERIAL ANALYSIS OF PLASTIC & RUBBER USING FTIR PA
2、GE: 1/3 ISSUED DATE: 1996. 05. 09 REVISED DATE: 2006. 06. 19 VERSION: 3 GM DAEWOO Auto & Technology 1. PURPOSE This standard aims at specifying the analysis method of plastic and rubber parts used for automobiles using FTIR. 2. EQUIPMENT 2.1. FTIR (Fourier transform infrared spectroscopy) 2.2. Centr
3、ifugal separator 2.3. Hot plate 2.4. 50 ml, 100 ml beakers 2.5. Toluene, Chloroform 2.6. Test tube 2.7. Pyrolyzer 2.8. KRS window 3. PRINCIPLE OF TEST FTIR is a method of performing qualitative and quantitative analysis with the infrared absorption spectrum obtained by measuring the absorbed quantit
4、y of the gas, liquid or solid sample for each frequency when the infrared beam (frequency: 4,000 400 cm) passes through them. The infrared beam absorption spectrum is expressed by a graph with the frequency in the x-axis and the trasmittance or absorbance in the y-axis. The peculiar molecule of the
5、plastic and rubber always repeats movement. Its kinetic energy remains in the similar wavelength range of the infrared beam. When the infrared beam is scanned, the infrared beam wavelength corresponding to the kinetic energy of the molecule is absorbed or transmitted to show a peculiar wavelength ba
6、nd. The peculiar infrared beam wavelength band resulting from the molecular movement confirms the molecular structure of the sample to allow qualitative analysis of the sample. 4. SAMPLE PREPARATION 4.1. Pre-conditioning of plastic parts 4.1.1. Melting Take a portion of the part free from defected m
7、atters and insert it between two glass plates. Raising the temperature to above the melting point of the plastic and pressing the piece between two glass plates produces a sample that has the transparency to permit transmission of light. 4.1.2. Purification EDS-T-7826TEST METHOD FOR MATERIAL ANALYSI
8、S OF PLASTIC & RUBBER USING FTIR PAGE: 2/3 ISSUED DATE: 1996. 05. 09 REVISED DATE: 2006. 06. 19 VERSION: 3 GM DAEWOO Auto & Technology Put some 1 mg of the sample into a mortar together with some 200 mg of potassium bromide powder for infrared beam spectrum. While cautioning not to get it damp, comp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST78262006TESTMETHODFORMATERIALANALYSISOFPLASTICRUBBERUSINGFTIRPDF

链接地址:http://www.mydoc123.com/p-757405.html