GMKOREA EDS-T-5520-2008 METHOD OF MEASUREMENT OF RADIATED NARROWBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE (VERSION 4 Replaced by GMW3091).pdf
《GMKOREA EDS-T-5520-2008 METHOD OF MEASUREMENT OF RADIATED NARROWBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE (VERSION 4 Replaced by GMW3091).pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5520-2008 METHOD OF MEASUREMENT OF RADIATED NARROWBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE (VERSION 4 Replaced by GMW3091).pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards METHOD OF MEASUREMENT OF RADIATED NARROWBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE Do Not Use on New Programs. Being Replaced by GMW3091 EDS-T-5520 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 (Sup
2、erceded) EDS-T-5520METHOD OF MEASUREMENT OF RADIATED NARROWBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE PAGE: 1/11 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. Variant Program). It is Sup
3、erceded for all future projects and replaced by GMW3091 1. PURPOSE This standard aims at specifying the methods of measuring narrowband electromagnetic emission from systems containing a microprocessor and other narrowband electromagnetic emission sources mounted in vehicles manufactured by GMDAT. T
4、he following shows some sources of narrowband electromagnetic emission: - System including digital logic - System including oscillator - System including clock generator 2. SCOPE This standard applies to all vehicles manufactured by GMDAT. 3. TEST SAMPLE (TEST VEHICLE) CONDITIONS At the normal tempe
5、rature, all functions of the test vehicle shall operate normally to meet design purposes. 4. DEFINITION OF TERMS 4.1. Narrowband electromagnetic emission Electromagnetic emission having smaller bandwidth than that of specific measuring instruments or receivers. 4.2. Open area test site : oats Test s
6、ite built to permit measuring of interference field intensity of electromagnetic waves radiated above the clear level ground that is free of objects reflecting electromagnetic waves, such as the surrounding building, electric cable, wall, tree, and underground cable and oil pipeline. 4.3. Substitute
7、 test laboratory (Semi-anechoic chamber) Facility designed to prevent reflection of electromagnetic wave by the electromagnetic wave absorbers installed on its boundary, it has the characteristics equivalent to the open area test site. 4.4. Ground plane A plane composed of the metal electric conduct
8、or or the conducting wire installed on the ground to acquire the same effect as grounding. 4.5. Ambient noise Radiated or transmitted noise that is present on a specific place without the object to be tested (test vehicle, etc.) being operated. EDS-T-5520METHOD OF MEASUREMENT OF RADIATED NARROWBAND
9、ELECTROMAGNETIC EMISSIONS FROM VEHICLE PAGE: 2/11 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 GM DAEWOO Auto & Technology 4.6. Sweep Continuous change or change by a small increment throughout the frequency band. 4.7. Peak detector Detector whose output voltage is represented as
10、the peak value of applied signals 4.8. Frequency window It is defined as the span between the starting frequency and ending frequency used in measurement or data recording. It is also called frequency span when the spectrum analyzer is used. 4.9. Resolution bandwidth (RBW) Bandwidth of the filter us
11、ed for discerning the noise frequency coming from electrical/electronic devices, it is usually -3dB and may be -6dB depending on the specifications. 4.10. Impulse bandwidth Bandwidth of the rectangular filter that has the same voltage response as that of the filter actually used In case the spectrum
12、 analyzer is used in test procedures of this standard, the impulse bandwidth has the following relation with the resolution bandwidth (RBW). Impulse (bandwidth = 1.5(selected RBW) 5. MEASURING FACILITIES 5.1. The measuring facilities shall meet requirements in items 1 and 2 of “Electromagnetic inter
13、ference prevention test method” Chapter 2 General test conditions, Paragraph 2 Measuring facilities, Clause 8 General conditions of measuring facilities. Of the Clause 9, Bandwidth of measuring instrumentand Clause 12, Test standspecified in item 2, those related to the latterClause 12, Test standsh
14、all be excluded. * Note : Item 2 stipulates that particulars not specified in Clause 9, Bandwidth of measuring instrumentand Clause 12, Test stand of item 2 shall follow the recommendations of CISPR. 5.2. The measuring facilities used for test shall have been calibrated on a regular basis. 5.3. Type
15、 of measuring facilities 5.3.1. Spectrum analyzer, radio noise meter, EMI test receiver The spectrum analyzer can be used. In case a radio noise meter is used, an auxiliary device capable of measuring quasi-peak value shall be connected. When equipment having correlation with the spectrum analyzer i
16、s used, clause 5.1 shall be met. (1) Calibration: To ensure accuracy of measuring instruments, calibration shall be conducted regularly according to the calibration factor shown in the manual instruction. Other peripheral devices used in measurement (Ex. cable, antenna) shall be calibrated together.
17、 (2) Display units: The linear scale is convenient only for observing low signal level data. In the vast area as in this EDS-T-5520METHOD OF MEASUREMENT OF RADIATED NARROWBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE PAGE: 3/11 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 GM DAEWOO
18、Auto & Technology test, the log scale is more appropriate, whose correlation is as follows: Level in dB V/m = 20*log10(Level in V/m) (3) Preamplifier: When very low level signals are detected or are likely to be detected, a preamplifier is used at the input end of the radio noise meter to improve th
19、e system sensitivity. When connected to the measuring instruments, double coaxial cable is required, and RF common-mode choke, such as ferrite core, may be inserted into the coaxial cable to reduce measuring error. (4) Instrumentation overload: Steps are provided to avoid overload of the preamplifie
20、r or radio noise meter. (5) Equipment noise floor: The noise floor of the measuring instrument shall be lower than the narrow band emission standard value of the test sample by 6dB. 5.3.2. Antenna (1) Biconical antenna 1) Frequency range : 20 KHz300 KHz 2) Reference point : Antenna center (2) Log-pe
21、riodic antenna 1) Frequency range : 300 KHz1000 KHz 2) Reference point : Antenna front end (3) Conical log-spiral antenna 1) Frequency range : 200 KHz1000 KHz 2) Reference point : Antenna front end (4) Any antenna may be used if it meets requirement for the reference antenna. (5) ForPreliminary prov
22、isional testin vehicle certification test, the antenna in the test vehicle shall be used. 5.3.3. Antenna master It shall be of the structure that permits change of the antenna height to the specified level and of the polarity to the vertically polarized and horizontally polarized waves and shall be
23、made of the non-conductive materials. 5.3.4. Impedance matching unit It is used when impedance matching with the test vehicle is required. 5.3.5. Antenna positioning controller It is used when the automatically adjustable antenna master is used in changing the antenna height and polarity. 5.3.6. Pro
24、cess controller It is used when the test is performed with the measuring instrument automatically adjusted through software. 5.3.7. Plotter or printer It is used to print out the measuring results. 6. TEST ENVIRONMENT (MEASURING PLACE) 6.1. Open area test site: The test in OATS shall be performed at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST55202008METHODOFMEASUREMENTOFRADIATEDNARROWBANDELECTROMAGNETICEMISSIONSFROMVEHICLEVERSION4REPLACEDBYGMW3091PDF

链接地址:http://www.mydoc123.com/p-757173.html