GMKOREA EDS-T-5519-2008 METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE (VERSION 4 Replaced by GMW3091).pdf
《GMKOREA EDS-T-5519-2008 METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE (VERSION 4 Replaced by GMW3091).pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5519-2008 METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE (VERSION 4 Replaced by GMW3091).pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE Do Not Use on New Programs. Being Replaced by GMW3091 EDS-T-5519 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 (Supe
2、rceded) EDS-T-5410METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE PAGE: 1/12 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. Variant Program). It is Super
3、ceded for all future projects and replaced by GMW3091 1. PURPOSE This standard aims at specifying the method of measuring broadband emission from the spark ignition system and electric parts (motors, relays) of the vehicles manufactured by GMDAT. 2. SCOPE This standard applies to all vehicles manufa
4、ctured by GMDAT. 3. TEST SAMPLE (TEST VEHICLE) CONDITIONS At the normal temperature, all functions of the test vehicle shall operate normally to meet design purposes. 4. DEFINITION OF TERMS 4.1. Broadband electromagnetic emission Electromagnetic emission having a larger bandwidth than that of specif
5、ic measuring instruments or receivers. It generally refers to electromagnetic emission from the ignition system and brush type DC motor. 4.2. Open area test site : OATS Test site built to permit measuring of interference field intensity of electromagnetic waves radiated above the clear level ground
6、that is free of objects reflecting electromagnetic waves, such as the surrounding building, electric cable, wall, tree, and underground cable and oil pipeline. 4.3. Substitute test laboratory (Semi-anechoic chamber) Facility designed to prevent reflection of electromagnetic wave by the electromagnet
7、ic wave absorbers installed on its boundary, it has the characteristics equivalent to the open area test site. 4.4. Ground plane A plane composed of the metal electric conductor or the conducting wire installed on the ground to acquire the same effect as grounding. 4.5. Ambient noise Radiated or tra
8、nsmitted noise that is present on a specific place without the object to be tested (test vehicle, etc.) being operated. 4.6. Sweep Continuous change or change by a small increment throughout the frequency band. 4.7. Peak detector EDS-T-5410METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC
9、EMISSIONS FROM VEHICLE PAGE: 2/12 ISSUED DATE: 1994. 11. 11 REVISED DATE: 2008. 11. 04 VERSION: 4 GM DAEWOO Auto & Technology Detector whose output voltage is represented as the peak value of applied signals 4.8. Quasi-peak detector Detector whose output voltage represents a fraction of the peak pul
10、se and the value approaches unity with increase of the pulse repetition rate when the same type of regularly repeated pulse is applied to the detector having a specified electric time constant. 4.9. Frequency window It is defined as the span between the starting frequency and ending frequency used i
11、n measurement or data recording. It is also called frequency span when the spectrum analyzer is used. 4.10. Resolution bandwidth (RBW) Bandwidth of the filter used for discerning the noise frequency coming from electrical/electronic devices, it is usually -3dB and may be -6dB depending on the specif
12、ications. 4.11. Impulse bandwidth Bandwidth of the rectangular filter that has the same voltage response as that of the filter actually used In case the spectrum analyzer is used in test procedures of this standard, the impulse bandwidth has the following relation with the resolution bandwidth (RBW)
13、. Impulse (bandwidth = 1.5(selected RBW) 5. MEASURING FACILITIES 5.1. The measuring facilities shall meet requirements in items 1 and 2 of “Electromagnetic interference prevention test method” Chapter 2 General test conditions, Paragraph 2 Measuring facilities, Clause 8 General conditions of measuri
14、ng facilities. Of the Clause 9, Bandwidth of measuring instrumentand Clause 12, Test standspecified in item 2, those related to the latterClause 12, Test standshall be excluded. * Note : Item 2 stipulates that particulars not specified in Clause 9, Bandwidth of measuring instrumentand Clause 12, Tes
15、t stand of item 2 shall follow the recommendations of CISPR. 5.2. The measuring facilities used for test shall have been calibrated on a regular basis. 5.3. Type of measuring facilities 5.3.1. Spectrum analyzer, radio noise meter, EMI test receiver The spectrum analyzer can be used. In case a radio
16、noise meter is used, an auxiliary device capable of measuring quasi-peak value shall be connected. When equipment having correlation with the spectrum analyzer is used, clause 5.1 shall be met. (1) Calibration: To ensure accuracy of measuring instruments, calibration shall be conducted regularly acc
17、ording to the calibration factor shown in the manual instruction. Other peripheral devices used in measurement (Ex. cable, antenna) shall be calibrated together. EDS-T-5410METHOD OF MEASUREMENT OF RADIATED BROADBAND ELECTROMAGNETIC EMISSIONS FROM VEHICLE PAGE: 3/12 ISSUED DATE: 1994. 11. 11 REVISED
18、DATE: 2008. 11. 04 VERSION: 4 GM DAEWOO Auto & Technology (2) Display units: The linear scale is convenient only for observing low signal level data. In the vast area as in this test, the log scale is more appropriate, whose correlation is as follows: Level in dB V/m = 20*log10(Level in V/m) (3) Pre
19、amplifier: When very low level signals are detected or are likely to be detected, a preamplifier is used at the input end of the radio noise meter to improve the system sensitivity. When connected to the measuring instruments, double coaxial cable is required, and RF common-mode choke, such as ferri
20、te core, may be inserted into the coaxial cable to reduce measuring error. (4) Instrumentation overload: Steps are provided to avoid overload of the preamplifier or radio noise meter. (5) Equipment noise floor: The noise floor of the measuring instrument shall be lower than the narrow band emission
21、standard value of the test sample by 6dB. 5.3.2. Antenna (1) Biconical antenna 1) Frequency range : 20 KHz300 KHz 2) Reference point : Antenna center (2) Log-periodic antenna 1) Frequency range : 300 KHz1000 KHz 2) Reference point : Antenna front end (3) Conical log-spiral antenna 1) Frequency range
22、 : 200 KHz1000 KHz 2) Reference point : Antenna front end (4) Any antenna may be used if it meets requirement for the reference antenna. 5.3.3. Antenna master It shall be of the structure that permits change of the antenna height to the specified level and of the polarity to the vertically polarized
23、 and horizontally polarized waves and shall be made of the non-conductive materials. 5.3.4. Antenna positioning controller It is used when the automatically adjustable antenna master is used in changing the antenna height and polarity. 5.3.5. Process controller It is used when the test is performed
24、with the measuring instrument automatically adjusted through software. 5.3.6. Plotter or printer It is used to print out the measuring results. 6. TEST ENVIRONMENT (MEASURING PLACE) 6.1. Open area test site: The test in OATS shall be performed at the center of a 30 m radius level clear area midway b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST55192008METHODOFMEASUREMENTOFRADIATEDBROADBANDELECTROMAGNETICEMISSIONSFROMVEHICLEVERSION4REPLACEDBYGMW3091PDF

链接地址:http://www.mydoc123.com/p-757172.html