1、GeneralSpecificationElectrical Function GME15339Wiring HarnessWork Instruction1 ScopeThis standard stipulates work instructions to wiringharnesses with regard to routing and mounting.Note: Nothinginthisstandardsupersedesapplicablelaws and regulations.Note: In the event of a conflict between the Eng-
2、lish and the domesticlanguage, the English languageshall take precedence.2 ReferencesNote: Only the latest approved standards are appli-cable unless otherwise specified.2.1 External Standards/Specifications. None.2.2 GM Standards/Specifications.GME15337GMW3191ON 2023 Work InstructionSymbols:3.1 Conn
3、ectors and Terminals. Electrical Connec-tors to GMW3191.General: The harness manufacturer must either useapplicators from the terminal manufacturer or if appli-cators of any other kind are going to be used, the har-ness manufacturer shall verify those applicators andcrimp process parameters together
4、 with the terminalmanufacturer. The harness manufacturer is respon-sible for verifying every cable dimension (and combi-nationofdimensionsandcableterminal)togetherwiththe terminal manufacturer.If more than one cable with different cross sections isfitted into the same terminal, the smallest cable sh
5、allbe located at the bottom in the insulation clamp.Connector housing shall be fixed to the harnessbranch so that mating connector and locking deviceremain accessible.In delivery condition attached with krepp tape orequivalent, width 12 mm, if used permanent in dryareas or will be removed in product
6、ion.In delivery condition insulated attached.Cables are secured with a strap to housing.Fixed by wrapping around insulating tape, optionalwrapping tape to be used.Cables are secured with a strap. Copyright 2009 General Motors Corporation All Rights ReservedPublication Department: GME EngineeringJuly
7、 2009 - Issue No. 3 Page 1 of 6PRD045 - VPRE ST 1 10/03 GME15339 GM EUROPE ENGINEERING STANDARDSWire shall be routed over the specified covering andoutside of cable channels (see harness drawing fordetails). It shall be fixed by CWC or cable ties. Nospiral routing around the branch allowed.Mating fa
8、ce of the connector housing coveredwith insulating tape and housing insulated with1 lap maximum tape on delivery detachable (appliedwith flag for easy removal). Branch attached tothe harness with 3 laps maximum of krepp tape orequivalent, width 12 mm in a way that the insulationtape remain accessibl
9、e (shall be free of krepp tape).In delivery condition attached with fabric adhesivetape or equivalent, if not CBB.In delivery unlocked.Terminal over complete length, acid free soldered tocore.Solder-free clamp fitted, including insulation permis-sible voltage drop 25 mV max. at 5 A/mm2 loadafter sal
10、t spray fog testing to GMW3191.3.2 Coverings.General: Coverings shall start 15 mm from thebackside of the connector. In cases where no hous-ing exists (terminals) the covering shall not extendbeyond the end of the crimp area, unless other-wisespecified.Structure from the inside outward.Coverings sta
11、rting 30 mm from housing connectorback side.Coverings shall reach to the back of the connectorhousing without interfering with contact location.No wires visible, unless colour black.Coverings fixed to the harness.3.2.1 Conduits, Sleeves, Grommets.General: On slotted convoluted conduits, wire shallno
12、t exit slit.Wires in the cut-off area (e.g. at the end of the con-voluted conduit resp. wires passing through the slitof the convoluted conduit) protected with tape in thearea of the slit/edge).End of convoluted conduit closed by taping (slit andcut off) unless otherwise specified.When reduction of
13、convoluted conduits, the overlapshall be 30 mm and be fixed.Branch fitted at convoluted conduits diameter. Mate-rialof thebranch fittingshall bethesameas the mate-rial of the conduit. Copyright 2009 General Motors Corporation All Rights ReservedPage 2 of 6 Issue No. 3 - July 2009PRD045 - VPRE ST G 1
14、0/03 GM EUROPE ENGINEERING STANDARDS GME15339Branch fixed by X- or T-type taping. In case of con-voluted conduit/tube: tape over the conduit/sleeve.Branch flexible, convoluted conduit cut-off, all sleev-ings fixed to the harness by taping, wires shall not bevisible even if extremely bend.End pieceor
15、 lockingpiecefittedatconvoluted conduitdiameter and convoluted conduit profile from MRG toGME15337 length 30 mm (MRH to GME15337).Guard grommet is with mounting strap attached toconnector housing female, fix in position as shown.3.2.2 Tape.General The type of tape shall beapproved by GME.Spirally ov
16、erlapping shall be wrapped (30.50) %.At the beginning and end of gap-taping the tape shallbe fastened with 2 overlapping turns.When gap-taping the tape, the recommendation is torelate the width of tape to the wire harness diameteras follows:Wire harness diameterin mmMaximum tape widthin mm53 9 0.510
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GME153392009WIRINGHARNESSWORKINSTRUCTIONENGLISHPDF

链接地址:http://www.mydoc123.com/p-754895.html