FORD WSS-M1L123-A4-2004 CABLE LOW TENSION POLYETHYLENE INSULATED THIN WALL THICKNESS FLEX FUEL RESISTANT TO BE USED WITH FORD WSS-M99P1111-A 《薄壁型耐弯曲燃料的聚乙烯绝缘的低压电缆 与标准FORD WSS-M99.pdf
《FORD WSS-M1L123-A4-2004 CABLE LOW TENSION POLYETHYLENE INSULATED THIN WALL THICKNESS FLEX FUEL RESISTANT TO BE USED WITH FORD WSS-M99P1111-A 《薄壁型耐弯曲燃料的聚乙烯绝缘的低压电缆 与标准FORD WSS-M99.pdf》由会员分享,可在线阅读,更多相关《FORD WSS-M1L123-A4-2004 CABLE LOW TENSION POLYETHYLENE INSULATED THIN WALL THICKNESS FLEX FUEL RESISTANT TO BE USED WITH FORD WSS-M99P1111-A 《薄壁型耐弯曲燃料的聚乙烯绝缘的低压电缆 与标准FORD WSS-M99.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2004 02 18 Revised Revised Table 2 S. White 2003 06 24 Revised Para 3.0 inserted; Para 3.1, 3.2, 3.3, 3.7, 4 deleted 1999 06 16 Activated S. White Printed copies are uncontrolled Copyright 2004, Ford Global Technologies, LLC Page 1 of 5 CABLE,
2、 LOW TENSION, POLYETHYLENE INSULATED, WSS-M1L123-A4 THIN WALL THICKNESS, FLEX FUEL RESISTANT 1. SCOPE The material defined by this specification is a low tension stranded cable insulated with cross-linked polyethylene. The cable is similar to SAE J 1128, Type TXL. 2. APPLICATION This specification w
3、as originally released for automotive applications requiring the use of insulated low tension cable to be exposed to automotive flex fuels. Note: The assemblers of electrical wire harnesses shall use the bulk wire suppliers as shown in the Ford Motor Company Materials Approved Source List. 3. REQUIR
4、EMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.4 CONDUCTOR 3.4.1 Unless otherwise specified, the individual strands of the conductor shall be soft or annea
5、led copper conforming to ASTM B 3, except strand dimensions. These dimensions shall be controlled to yield the cross-sectional area listed for the conductor of the finished cable per Table 1. Conductor area shall be determined by measuring individual strand diameters and calculating the sum of the i
6、ndividual strand areas. As an alternate method, conductor area may also be determined in accordance with ASTM B 263. For this procedure, let k=2 in accordance with ASTM B 174, para. 12.3. 3.4.2 The strands shall be bunched per ASTM B 174. The maximum lay length shall be as specified in ASTM B 174 Ta
7、ble 2, Column A. Conductor strand count shall comply with Table 1. Missing strands are not allowed. 3.5 INSULATION 3.5.1 The color of the insulation shall be specified on the engineering drawing of the component utilizing this material. Base and stripe colors shall correspond to SAE J 1128. Where st
8、riping is specified, one or two stripes may be used. The width of the stripe(s) shall be a minimum of 0.3 mm but not more than 15% of the circumference of the wire. If the insulation is dyed or painted, all cable quality tests in Section 3.6 must be performed on the finished product. The insulation
9、and the color may show no evidence of peeling or cracking and must conform to the color tolerances specified with the exception of quality tests 3.6.2 and 3.6.3. ENGINEERING MATERIAL SPECIFICATIONWSS-M1L123-A4Printed copies are uncontrolled Copyright 2004, Ford Global Technologies, LLC Page 2 of 5 3
10、.5.2 The insulating material shall be flame retardant, homogeneous, cross-linked polyethylene, similar to SAE J 1128, Type TXL. The material shall adhere closely to, but strip readily from the conductors, leaving them free of insulation and in suitable condition for applying terminals. 3.5.3 Insulat
11、ion Mechanical Properties These tests shall be conducted in accordance with SAE J 1128, for Type TXL, except that the insulation shall be conditioned for 24 +/- 2h at 60 +/- 2 C prior to taking original measurements and that the aging test temperature shall be 160 +/- 2 C. 3.5.4 Insulation thickness
12、 shall comply with the requirements of Table 2. Insulation thickness shall be measured with an optical device accurate to at least 0.01 mm or a pin micrometer with a diameter of 0.5 mm. The test method for determining minimum insulation thickness at any point shall be in accordance with ANSI/UL-1581
13、, Reference Standard for Electrical Wires, Cables and Flexible Cords, Paras 240 through 250.11. In case of dispute, the referee method shall be the optical device. 3.6 CABLE QUALITY TESTS The following tests: Dielectric Test, Cold Bend Test, Flame Test, Fluid Compatibility Test, Ozone Resistance, Pi
14、nch Test, Abrasion Resistance, Cross linking, and Strip Force shall be conducted per SAE J 1128 for type TXL cable. The tests listed below shall be conducted in addition to the tests listed above. 3.6.1 Cable Diameter Measure the outside diameter of a 2000 mm specimen with an optical measurement dev
15、ice accurate to +/- 0.01 mm (other devices may be used but the referee method will be the optical device) by taking a minimum of 2 readings approximately 90 apart. Move the sample approximately 400 mm and repeat the procedure for a total of five cross-sections. The mean of all the readings will dete
16、rmine the outside diameter of the cable. The outside diameter will conform to the values listed in Table 2. 3.6.2 High Temperature Resistance 25 mm of insulation shall be removed from each end of a 600 mm sample of finished cable. The sample shall be suspended around a cylindrical mandrel having a d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSSM1L123A42004CABLELOWTENSIONPOLYETHYLENEINSULATEDTHINWALLTHICKNESSFLEXFUELRESISTANTTOBEUSEDWITHFORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-752462.html