FORD FLTM BO 040-01-2018 SHORT AND LONG TERM ENVIRONMENTAL TESTING.pdf
《FORD FLTM BO 040-01-2018 SHORT AND LONG TERM ENVIRONMENTAL TESTING.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BO 040-01-2018 SHORT AND LONG TERM ENVIRONMENTAL TESTING.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BO 040-01 Date Action Revisions Rev. 02 2018 07 27 Revised See Summary of Revisions L. Rabideau, NA 2018 01 19 Revised Added additional time/temperature for floor consoles L. Schmalz, NA 2016 07 08 Released L. Sinclair, NA Controlled document at www.MATS Copyright 2018,
2、Ford Global Technologies, LLC Page 1 of 3 SHORT AND LONG TERM ENVIRONMENTAL TESTING Application This procedure is used to determine the dimensional stability, function and visual/tactile performance of a component after undergoing short term cyclic and/or long term heat exposure testing. Apparatus a
3、nd Materials Required Environmental Cabinet Capable of maintaining controlled temperature and humidity conditions to +/- 1 C and +/- 2% relative humidity. Oven As described in ASTM D573 Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly. Each par
4、ty is responsible for determining proper use and handling in its facilities. Sample Preparation All parts shall be fully trimmed including all components packaged in the environment (eg. speakers, hardware, wiring, etc.) and assembled onto actual or representative production support foundations. Thi
5、s includes not only all attaching points, but also any boundary conditions that may restrict movement, unless otherwise specified by the responsible PD Engineer. The retention methods, attachments, and supporting garnish moldings (if any), shall be the same as proposed for production. Measurement Lo
6、cation 1. Every twenty centimeters and at the points of greatest movement between the twenty centimeter marks along the parts outside edges and internal openings or as defined by PD Engineering. Some parts may have specific measurement locations required by PD Engineering, which will override the 20
7、 cm required. Part specific measurement locations to be signed off by PD Engineering prior to test. 2. The “significant characteristics locations“ specified on the engineering drawing. 3. Unique requirements will be noted in the applicable performance specification. Measurement Technique The movemen
8、t at each measurement point shall be recorded in two directions: (1) in the x/y plane from the observers view, and (2) in the z-dimension direction into or out of the x/y plane from the observers view. The observers view shall remain consistent always viewing from the front side of the part. Room te
9、mperature is defined as 23 +/- 2C. If pre-evaluation or evaluation are performed outside of the room temperature range, record the temperature of the room in the test report. FORD LABORATORY TEST METHOD BO 040-01 Copyright 2018, Ford Global Technologies, LLC Page 2 of 3 Procedure A: Short Term Heat,
10、 Humidity and Cold Cycle 1. Visually evaluate the part before the test. Note any defects on the component prior to testing. 2. Measure the part and record the data at all specified locations at room temperature before cycling on the production support foundation or test fixture. Any visual defects/i
11、mperfections must be noted in the test report and signed off by PD Engineering for compliance. 3. Use test chambers with automated programmable test cycles for the listed test conditions below. Note that stages do not include ramp times to transition from level to level. Each specimen can have diffe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBO040012018SHORTANDLONGTERMENVIRONMENTALTESTINGPDF

链接地址:http://www.mydoc123.com/p-747331.html