FORD FLTM BJ 016-1-2000 FOUR-BALL WEAR TEST FOR LUBRICATING FLUIDS.pdf
《FORD FLTM BJ 016-1-2000 FOUR-BALL WEAR TEST FOR LUBRICATING FLUIDS.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BJ 016-1-2000 FOUR-BALL WEAR TEST FOR LUBRICATING FLUIDS.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BJ 016-01 Date Action Revisions 2000 08 31 Revised Editorial no technical change A. Cockman 1992 05 13 Printed copies are uncontrolled Page 1 of 4 Copyright 2000, Ford Global Technologies, Inc. FOUR-BALL WEAR TEST FOR LUBRICATING FLUIDS Application This procedure may be
2、used to determine the anti - wear properties of lubricating fluids. Apparatus Required Shell 4-ball Wear Tester Source: Precision Scientific Co. Chicago, Illinois or other ac ceptable source. Balls 1/2 inch diameter, steel. Hardness, Rockwell C64. Microscope With grid measuring in fractions of a mil
3、limeter. Timing Device Stopwatch, clock, watch or other. Solvents Benzol or naphtha. Note: No chlorinated solvents should be used as a surface film may be formed yielding erroneous results. Temperature Controller Limits of Variables 1. Load: 40 kilograms, max 2. Temperature: 0 to 300 F 3. Speeds: 60
4、0, 1200, 1800 rpm 4. Time: Indefinite The above variables are to be sp ecified by the Ford specification for the lubricant. FORD LABORATORY TEST METHOD BJ 016-01 Page 2 of 4 Copyright 2000, Ford Global Technol ogies, Inc. Conditioning and Test Conditions All test values indicated herein are based on
5、 material conditioned in a controlled atmosphere of 23 +/ - 2 C and 50 +/ - 5 % relative humidity for not less than 24 h pri or to testing and tested under the same conditions unless otherwise specified. Procedure 1. The specified speed for the test is obtained by placing the belt in the proper pull
6、ey of the three -step arrangement. 2. The ball pot assembly, four balls and spi ndle and chuck assembly are cleaned thoroughly in benzol or naphtha. 3. One ball is inserted into the spindle and chuck assembly, care being taken to avoid fingerprints and the assembly is inserted in the headstock of th
7、e machine. 4. The other three ball s are placed in the ball pot assembly, again avoiding fingerprints and the assembly is inserted in the headstock of the machine. 5. Ten milliliters of the fluid to be tested is placed in the ball pot assembly. Ten milliliters brings the level to the top of the ball
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBJ01612000FOURBALLWEARTESTFORLUBRICATINGFLUIDSPDF

链接地址:http://www.mydoc123.com/p-747100.html