FORD FLTM BJ 012-1-2001 MERC-O-MATIC TRANSMISSION FLUID OXIDATION BENCH TEST.pdf
《FORD FLTM BJ 012-1-2001 MERC-O-MATIC TRANSMISSION FLUID OXIDATION BENCH TEST.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BJ 012-1-2001 MERC-O-MATIC TRANSMISSION FLUID OXIDATION BENCH TEST.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BJ 012-01 Date Action Revisions 2001 07 24 Revised Editorial no technical change A. Cockman 1992 05 08 Printed copies are uncontrolled Page 1 of 19 Copyright 2001, Ford Global Technologies, Inc. MERC-O-MATIC TRANSMISSION FLUID OXIDATION BENCH TEST Application This proced
2、ure is used to determine the high temperature oxidation stability of automatic transmission fluids and any other similar fluids. Summary of Test Method This method consists of constant speed operation of an automatic transmission for a prescribed time at a specified temperature with air passing thro
3、ugh the fluid. As measures of oxidation, changes in the properties of the fluid are determined and deposits in the transmission are rated at the end of the test. Apparatus Required Transmission A new current model three speed automatic transmission shall be used for each test. Source: Transmission D
4、ivision Sales the transmission is removed from the stand and the converter is drained. The transmission is then remounted on the stand. Test Procedure 1. Introduce 4.7 L of the fluid to be tested into the transmission at approximately 105 rad/s. 2. Shut down and introduce another 4.7 L of fluid. 3.
5、Shift transmission into the drive position. 4. Start motor and operate at 225 rad/s bringing transmission to the test temperature within 4 h. Adjust the T-V adaptor fitting to maintain a transmission pressure of 550 +/- 30 Pa. 5. After the unit reaches the test temperature, open and adjust the air b
6、leed valve to draw air into the transmission at a rate of 200 +/- 4 mL per minute at a temperature and pressure of 20 C and 101 kPa. This air flow is to be maintained except during warm-up and the air is to be drawn in from outside the insulated box. FORD LABORATORY TEST METHOD BJ 012-01 Page 6 of 1
7、9 Copyright 2001, Ford Global Technologies, Inc. 6. Continue to operate 24 h per day at the speed and temperature until 300 h are logged. At 100 and 200 h withdraw a 2 ounce sample and shut down the test allowing the transmission to cool to 23 +/- 2 C. Tests must be scheduled by laboratories on a no
8、rmal five day schedule, so that scheduled shut downs coincide with normal weekend shut downs. If upon completion of 300 test hours, less than 288 hours are logged at the required temperature, continue the run beyond the 300 hours until 288 hours at the test temperature have been completed. 7. Termin
9、ate test if total oil loss for a test including sample should exceed 300 mL. No new fluid may be added during the test. 8. Air out of the transmission should be checked periodically at the transmission vent. This may be done with a soap film flowmeter of the type illustrated in Figure 5. Air out of
10、the transmission should generally be between 170 and 190 mL/minute corrected to 20 C and 101 kPa. If the air out is greater than 190 mL/minute then transmission setup should be examined for leaks. If less than 170 mL/minute, the air bleed system should be checked for leaks, restrictions, flowmeter c
11、alibration, etc. The air out of the transmission should be checked daily. Note: Instruments used in the test should be calibrated frequently enough to insure that test conditions are met within the test tolerance. Inspection Procedure 1. Running Inspection: Take small samples of fluid every 25 hours
12、 and place 1 - 2 drops on a blotter pad. The color of the stain provides a subjective means of following the oxidation of the oil. 2. Take 60 mL samples of fluid each 100 hours. 3. After completion of 300 hours, or 288 hours time at the required temperature, whichever is longer, shut down and disass
13、emble the transmission; cut the converter open around the weld and inspect thoroughly. 4. Rate the individual components according to the Coordinating Research Council Deposit Rating Scale (CRC Manual 9) for varnish and Area Depth Method (CRC Manual 10) for sludge. Ten represents a perfectly clean p
14、art. FORD LABORATORY TEST METHOD BJ 012-01 Page 7 of 19 Copyright 2001, Ford Global Technologies, Inc. Rating Procedure The following data shall be recorded on the standard Merc-O-Matic Test Data form (Figure 7). 1. Inspect all transmission parts for sludge and varnish after the test. Specifically i
15、nspect and rate according to the CRC Varnish and Sludge Rating System the following parts: Part Name Varnish Sludge Turbine Outer Surface X Converter Housing, Sludge Ring X Screen, Oil X X Steel Clutch Plates X Valve Body - Outer Surface X Valve Body - Separator Plate X Valve Body Spools X Valve Bod
16、y Cavities X X Clutch Pistons X Clutch Cylinders X Sun Gear Shaft X Bottom of Transmission X 2. Record the condition of the following: Oil Seals: Cracking, flexibility, etc. when bent 180 deg. Silicone Seal: Reversion Brass Washers: Corrosion, wear, discoloration Bearings: Wear, corrosion, metal tra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBJ01212001MERCOMATICTRANSMISSIONFLUIDOXIDATIONBENCHTESTPDF

链接地址:http://www.mydoc123.com/p-747091.html