FORD FLTM AN 102-2-2001 DETERMINATION OF WEIGHT OF COMPONENTS IN POLYETHYLENE-BACKED CARPET (Replaces FLTM EU-AN 002-02).pdf
《FORD FLTM AN 102-2-2001 DETERMINATION OF WEIGHT OF COMPONENTS IN POLYETHYLENE-BACKED CARPET (Replaces FLTM EU-AN 002-02).pdf》由会员分享,可在线阅读,更多相关《FORD FLTM AN 102-2-2001 DETERMINATION OF WEIGHT OF COMPONENTS IN POLYETHYLENE-BACKED CARPET (Replaces FLTM EU-AN 002-02).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD AN 102-02 Date Action Revisions 2001 01 30 Revised Editorial no technical change A. Cockman 2000 04 14 Editorial no technical change A. Cockman 1994 09 13 Printed copies are uncontrolled Page 1 of 4 Copyright 2001, Ford Global Technologies, Inc. DETERMINATION OF WEIGHT O
2、F COMPONENTS IN POLYETHYLENE-BACKED CARPET Application This procedure is used to determine the weight of the various components of polyethylene-backed automotive carpeting materials used as floor coverings, luggage liners, trim panels and other applications. This extraction procedure will remove pol
3、yethylene, wax and other materials which are soluble in toluene or xylene. Apparatus Required Beakers One - 2000 mL Two - 1000 mL Watch Glass Appropriate size to cover 2000 mL beaker. Hot Plate Flameless hot plate - capable of maintaining the solvent at a moderate boil. Drying Ovens Mechanical Conve
4、ction - capable of being maintained at 38 +/- 2 C and 102 +/- 2 C. Screen U. S. No. 50 mesh sieve Desiccator Analytical Balance Accurate to +/- 0.0001 g. Cutting Die 152.4 x 152.4 mm FORD LABORATORY TEST METHOD AN 102-02 Page 2 of 4 Copyright 2001, Ford Global Technologies, Inc. Materials Required F
5、ilter Paper Whatman No. 42 or equivalent Absorbent Paper Towel Xylene or Toluene Technical grade. CAUTION: Low flash point. Refer to Fire Control Bulletin No. 18. Desiccant Drierte or equivalent. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a
6、 controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. Die cut three test specimens across the width of the carpet. Each sample should be cut at least 250 mm from the
7、edge of the roll. 2. Clean and dry the beakers and place in an oven for 15 minutes at 102 C. 3. Remove the beakers from the oven and place in a desiccator. Allow to cool to 23 +/- 2 C. 4. Weigh each beaker to the nearest milligram (1000 mL beaker = W1 and W1*; 2000 mL beaker = W2). 5. Place a test s
8、pecimen in the 2000 mL beaker and record weight (W3). W3 - W2 = Weight of test specimen (W4) 6. Add approximately 600 mL of xylene or toluene to the 2000 mL beaker containing the sample, and cover with a watch glass. 7. Place the beaker on a hot plate and adjust the hot plate to maintain moderate bo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMAN10222001DETERMINATIONOFWEIGHTOFCOMPONENTSINPOLYETHYLENEBACKEDCARPETREPLACESFLTMEUAN00202PDF

链接地址:http://www.mydoc123.com/p-746802.html