EN ISO TR 52019-2-2017 en Energy performance of buildings - Hygrothermal performance of building components and building elements - Part 2 Explanation and justification.pdf
《EN ISO TR 52019-2-2017 en Energy performance of buildings - Hygrothermal performance of building components and building elements - Part 2 Explanation and justification.pdf》由会员分享,可在线阅读,更多相关《EN ISO TR 52019-2-2017 en Energy performance of buildings - Hygrothermal performance of building components and building elements - Part 2 Explanation and justification.pdf(72页珍藏版)》请在麦多课文档分享上搜索。
1、Energy performance of buildings - Hygrothermal performance of building components and building elementsPart 2: Explanation and justification (ISO/TR 52019-2:2017)PD CEN ISO/TR 52019-2:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis Published
2、 Document is the UK implementation of CEN ISO/TR 52019-2:2017. It is identical to ISO/TR 52019-2:2017.The UK participation in its preparation was entrusted to Technical Committee B/540/2, Building performance - Moisture.A list of organizations represented on this committee can be obtained on request
3、 to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017ISBN 978 0 580 91586 4ICS 91.120.10Compliance with a British Sta
4、ndard cannot confer immunity from legal obligations.This Published Document was published under the authority of the Standards Policy and Strategy Committee on 30 November 2017.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CEN ISO/TR 52019-2:2017TECHNICAL REPOR
5、TRAPPORT TECHNIQUETECHNISCHER BERICHTCEN ISO/TR 52019-2July 2017ICS 91.120.10EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGCEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN Ref. No. CEN ISO/TR 52019-2:2017: EAll rights of ex
6、ploitation in any form and by any means reserved worldwide for CEN national MembersEnergy performance of buildings - Hygrothermal performance of building components and building elements - Part 2: Explanation and justification (ISO/TR 52019-2:2017)Performance nergtique des btiments - Performances hy
7、grothermiques des composants et parois de btiments - Partie 2: Explication et justification (ISO/TR 52019-2:2017)This Technical Report was approved by CEN on 24 February 2017. It has been drawn up by the Technical Committee CEN/TC 89.CEN members are the national standards bodies of Austria, Belgium,
8、 Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Sw
9、itzerland, Turkey and United Kingdom.English VersionISO 52019-2:2017(E)Foreword vIntroduction vi1 Scope .12 Normative references 13 Terms and definitions .14 Symbols and subscripts .25 Description of the methods .25.1 Outputs 25.2 General description . 26 ISO 6946 37 ISO 10211 48 ISO 13370 48.1 Gene
10、ral .48.2 Thermal properties of the ground .48.3 The influence of flowing ground water 48.4 Application to dynamic simulation programmes 48.5 Embedded heating or cooling systems 48.6 Cold stores 49 ISO 13786 410 ISO 13789 511 ISO 14683 5Annex A (informative) ISO 13370: Thermal properties of the grou
11、nd 6Annex B (informative) ISO 13370: The influence of flowing ground water 8Annex C (informative) ISO 13370: Application to dynamic simulation programmes .10Annex D (informative) ISO 13370: Slab-on-ground floor with an embedded heating or cooling system 18Annex E (informative) ISO 13370: Cold stores
12、 .19Annex F (informative) ISO 13370: Worked examples .20Annex G (informative) ISO 13786: Principle of the method and examples of applications 29Annex H (informative) ISO 13786: Information for computer programming .33Annex I (informative) ISO 13786: Examples 35Annex J (informative) ISO 13789: Inform
13、ation on type of dimensions 38Annex K (informative) ISO 13789: Ventilation airflow rates 40Annex L (informative) ISO 14683: Example of the use of default values of linear thermal transmittance in calculating the heat transfer coefficient 45Annex M (informative) Detailed worked examples for ISO 6946,
14、 ISO 13370 and ISO 13789 49Bibliography 58ii ISO 2017 All rights reservedContents PagePD CEN ISO/TR 52019-2:2017ISO 52019-2:2017(E)European forewordThis document (CEN ISO/TR 52019-2:2017) has been prepared by Technical Committee ISO/TC 163 “Thermal performance and energy use in the built environment
15、“ in collaboration with Technical Committee CEN/TC 89 “Thermal performance of buildings and building components” the secretariat of which is held by SIS.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held respons
16、ible for identifying any or all such patent rights.This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association.This document is part of the set of standards and accompanying technical reports on the energy performance of buildings a
17、nd has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association (Mandate M/480, see reference EF3 below).Directive 2010/31/EU recasting the Directive 2002/91/EC on energy performance of buildings (EPBD, EF4) promotes the improvement of the energy
18、performance of buildings within the European Union, taking into account all types of energy uses (heating, lighting, cooling, air conditioning, ventilation) and outdoor climatic and local conditions, as well as indoor climate requirements and cost effectiveness (Article 1).The directive requires Mem
19、ber States to adopt measures and tools to achieve the prudent and rational use of energy resources. In order to achieve those goals, the EPBD requires increasing energy efficiency and the enhanced use of renewable energies in both new and existing buildings. One tool for this is the application by M
20、ember States of minimum requirements on the energy performance of new buildings and for existing buildings that are subject to major renovation, as well as for minimum performance requirements for the building envelope if energy-relevant parts are replaced or retrofitted. Other tools are energy cert
21、ification of buildings, inspection of boilers and air-conditioning systems.The use of European standards increases the accessibility, transparency and objectivity of the energy performance assessment in the Member States facilitating the comparison of best practices and supporting the internal marke
22、t for construction products. The use of EPB standards for calculating energy performance, as well as for energy performance certification and the inspection of heating systems and boilers, ventilation and air-conditioning systems will reduce costs compared to developing different standards at nation
23、al level.The first mandate to CEN to develop a set of CEN EPBD standards (M/343, EF1), to support the first edition of the EPBD (EF2) resulted in the successful publication of all EPBD related CEN standards in 2007-2008. Mandate M/480 was issued to review the mandate M/343 as the recast of the EPBD
24、raised the need to revisit the standards and reformulate and add standards so that they become on the one hand unambiguous and compatible, and on the other hand a clear and explicit overview of the choices, boundary conditions and input data that need to be defined at national or regional level. Suc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISOTR5201922017ENENERGYPERFORMANCEOFBUILDINGSHYGROTHERMALPERFORMANCEOFBUILDINGCOMPONENTSANDBUILDINGELEMENTSPART2EXPLANATIONANDJUSTIFICATIONPDF

链接地址:http://www.mydoc123.com/p-727164.html