EN 60695-10-3-2016 en Fire hazard testing - Part 10-3 Abnormal heat - Mould stress relief distortion test.pdf
《EN 60695-10-3-2016 en Fire hazard testing - Part 10-3 Abnormal heat - Mould stress relief distortion test.pdf》由会员分享,可在线阅读,更多相关《EN 60695-10-3-2016 en Fire hazard testing - Part 10-3 Abnormal heat - Mould stress relief distortion test.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Fire hazard testingPart 10-3: Abnormal heat Mould stress relief distortion testBS EN 60695-10-3:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of EN 60695-10-3:2016. It isidentical to IEC 60695-10-3
2、:2016. It supersedes BS EN 60695-10-3:2002which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/89, Fire hazard testing.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to i
3、nclude all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 83870 5ICS 13.220.40; 29.020Compliance with a British Standard cannot confer immunity fromlegal obligation
4、s.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 November 2016.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60695-10-3:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60695-10-3 November 20
5、16 ICS 29.020 Supersedes EN 60695-10-3:2002 English Version Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test (IEC 60695-10-3:2016) Essais relatifs aux risques du feu - Partie 10-3 : Chaleur anormale - Essai de dformation par rduction des contraintes de moulage (IE
6、C 60695-10-3:2016) Prfungen zur Beurteilung der Brandgefahr - Teil 10-3: Unbliche Wrme - Prfung auf Verformung durch Abbau von Formspannungen (IEC 60695-10-3:2016) This European Standard was approved by CENELEC on 2016-10-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulati
7、ons which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC memb
8、er. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official version
9、s. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the N
10、etherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Managemen
11、t Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60695-10-3:2016 E BS EN 60695-10-3:2016EN 60695-10-3:2016 2 European foreword The text of document 89/1328/FDIS, future edition 2 of IE
12、C 60695-10-3, prepared by IEC/TC 89 “Fire hazard testing“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60695-10-3:2016. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national sta
13、ndard or by endorsement (dop) 2017-07-12 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-10-12 This document supersedes EN 60695-10-3:2002. Attention is drawn to the possibility that some of the elements of this document may be the subject of
14、 patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60695-10-3:2016 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliogr
15、aphy, the following notes have to be added for the standards indicated: IEC 60695-1-10 NOTE Harmonized as EN 60695-1-10. IEC 60695-1-11 NOTE Harmonized as EN 60695-1-11. BS EN 60695-10-3:2016EN 60695-10-3:2016 3 Annex ZA (normative) Normative references to international publications with their corre
16、sponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including a
17、ny amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publicati
18、on Year Title EN/HD Year IEC 60050 series International Electrotechnical Vocabulary - series IEC 60216-4-1 - Electrical insulating materials - Thermal endurance properties - Part 4-1: Ageing ovens - Single-chamber ovens EN 60216-4-1 - IEC 60695-4 2012 Fire hazard testing - Part 4: Terminology concer
19、ning fire tests for electrotechnical products EN 60695-4 2012 IEC Guide 104 - The preparation of safety publications and the use of basic safety publications and group safety publications - - ISO 13943 - Fire safety - Vocabulary EN ISO 13943 - ISO/IEC Guide 51 - Safety aspects - Guidelines for their
20、 inclusion in standards - - BS EN 60695-10-3:2016 2 IEC 60695-10-3:2016 IEC 2016 CONTENTS FOREWORD . 3 INTRODUCTION . 5 1 Scope 6 2 Normative references. 6 3 Terms and definitions 7 4 General description of the test . 7 5 Test apparatus 7 5.1 Heating oven . 7 5.2 Temperature measuring equipment 8 6
21、Test specimens . 8 7 Conditioning 8 8 Test procedure 8 8.1 General . 8 8.2 Parts exposed to uniform maximum operating temperatures . 8 8.3 Parts exposed to variations in operating temperatures . 9 8.4 Test setup . 9 9 Test criteria . 9 10 Information to be given in the relevant product specification
22、 . 9 11 Test report. 10 Bibliography . 11 BS EN 60695-10-3:2016IEC 60695-10-3:2016 IEC 2016 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ FIRE HAZARD TESTING Part 10-3: Abnormal heat Mould stress relief distortion test FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide or
23、ganization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activitie
24、s, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject deal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN606951032016ENFIREHAZARDTESTINGPART103ABNORMALHEATMOULDSTRESSRELIEFDISTORTIONTESTPDF

链接地址:http://www.mydoc123.com/p-718637.html