EN 50216-10-2009 en Power transformer and reactor fittings - Part 10 Oil-to-air heat exchangers《电源变压器及电抗器配件 第10部分 油气热交换器》.pdf
《EN 50216-10-2009 en Power transformer and reactor fittings - Part 10 Oil-to-air heat exchangers《电源变压器及电抗器配件 第10部分 油气热交换器》.pdf》由会员分享,可在线阅读,更多相关《EN 50216-10-2009 en Power transformer and reactor fittings - Part 10 Oil-to-air heat exchangers《电源变压器及电抗器配件 第10部分 油气热交换器》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Power transformer and reactorfittings Part 10: Oil-to-air heat exchangersBS EN 50216-10:2009raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsNational forewordThis British Standard is the UK implementation of EN 50216-10:2009.The UK
2、 participation in its preparation was entrusted to Technical CommitteePEL/14, Power transformers.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsi
3、ble for its correct application. BSI 2009ISBN 978 0 580 54740 9ICS 29.180BRITISH STANDARDBS EN 50216-10:2009Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 Apri
4、l 2009Amendments issued since publicationAmd. No. Date Text affectedEUROPEAN STANDARD EN 50216-10 NORME EUROPENNE EUROPISCHE NORM March 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normun
5、g Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50216-10:2009 E ICS 29.180 English version Power transformer and reactor fittings - Part 10: Oil-to-air heat exchanger
6、s Accessoires pour transformateurs de puissance et bobines dinductance - Partie 10: Echangeurs thermiques huile-air Zubehr fr Transformatoren und Drosselspulen - Teil 10: l-Luft-Khler This European Standard was approved by CENELEC on 2008-10-21. CENELEC members are bound to comply with the CEN/CENEL
7、EC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CE
8、NELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official version
9、s. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, S
10、lovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50216-10:2009EN 50216-10:2009 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text of the draft was submitted to the formal vote and was approved by CENELEC as
11、 EN 50216-10 on 2008-10-21. This European Standard is to be read in conjunction with EN 50216-1:2002, Power transformer and reactor fittings - Part 1: General. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national
12、standard or by endorsement (dop) 2009-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-11-01 _ BS EN 50216-10:2009 3 EN 50216-10:2009 Contents 1 Scope . 4 2 Normative references 4 3 Definitions 4 4 Requirements 5 4.1 Rated values . 5 4.2 Rated
13、 cooling capacity 5 4.3 Mechanical design 6 4.4 Protection of surfaces . 6 5 Designation 7 5.1 Designation of the heat exchangers . 7 5.2 Rating plate information 7 6 Tests . 8 6.1 Routine tests . 8 6.2 Type tests . 8 7 Preparation for transport and storage 8 8 Mounting and service, service conditio
14、ns . 8 Annex A (normative) Design details of heat exchangers 9 Annex B (normative) Performance of heat exchangers 12 Bibliography 16 Figures Figure A.1 Schematic design of cooling unit (without oil pump) Arrangement of flanges A1 . 9 Figure A.2 Versions of flange arrangement . 10 Figure B.1 General
15、diagram for cooling temperatures . 12 Figure B.2 Variation of cooling capacity as function of average oil temperature rise 13 Figure B.3 Variation of cooling capacity as function of air flow quantity . 14 Figure B.4 Variation of cooling capacity as function of oil flow quantity . 15 Tableaux Table A
16、.1 Parts list . 11 BS EN 50216-10:2009EN 50216-10:2009 4 1 Scope EN 50216-10 describes oil-to-air heat exchangers that means a heat exchanger for the cooling of the transformer oil using a forced oil circuit and a forced air circuit. The oil-to-air heat exchangers are not included in the scope of th
17、e Pressure Equipment Directive 97/23/EC according to Article 1, 3.12. This standard establishes essential dimensions and the requirements to ensure interchangeability and adequate mounting of the oil-to-air heat exchangers. 2 Normative references The following referenced documents are indispensable
18、for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendment) applies. EN 50216-1:2002 Power transformers and reactor fittings - Part 1: General EN 60296 Fluids for electrote
19、chnical applications - Unused mineral insulating oils for transformers and switchgear (IEC 60296) EN 60721-3-4 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected locations
20、(IEC 60721-3-4) EN 754-2 Aluminium and aluminium alloys - Cold drawn rod/bar and tube - Part 2: Mechanical properties EN 1092-1 Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories , PN designated - Part 1: Steel flanges EN 1386 Aluminium and aluminium alloys - Tre
21、ad plate - Specifications EN 10025:1990 1)Hot rolled products of non-alloy structural steels - Technical delivery conditions EN 10130 Cold rolled low carbon steel flat products for cold forming - Technical delivery conditionsEN 10217-1 Welded steel tubes for pressure purposes - Technical delivery co
22、nditions - Part 1: Non-alloy steel tubes with specified room temperature properties EN 12451 Copper and copper alloys - Seamless, round tubes for heat exchangers EN ISO 3506-1 Mechanical properties of corrosion-resistant stainless steel fasteners - Part 1: Bolts, screws and studs (ISO 3506-1) ISO 44
23、06 Hydraulic fluid power - Fluids - Methods for coding the level of contamination by solid particles 3 Definitions For the purposes of this document, the following terms and definitions apply. 3.1 oil header oil collecting and guiding compartment with flange connections to connect the heat exchanger
24、 with the oil circuit of the transformer 3.2 tube sheets tubes are connected at both ends with tube sheets. The connection must be oil tight 3.3 heat exchanger device for exchanging heat from one medium to the other 1)Replaced by EN 10025 series, Hot rolled products of structural steels. BS EN 50216
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN50216102009ENPOWERTRANSFORMERANDREACTORFITTINGSPART10OILTOAIRHEATEXCHANGERS 电源变压器 电抗 配件 10 部分 油气 热交换器

链接地址:http://www.mydoc123.com/p-716813.html