《EN 993-10-1997 en Methods of Test for Dense Shaped Refractory Products - Part 10 Determination of Permanent Change in Dimensions on Heating《密封成型耐火制品检验方法 第10部分 温度影响后恒定长度变化的测定》.pdf》由会员分享,可在线阅读,更多相关《EN 993-10-1997 en Methods of Test for Dense Shaped Refractory Products - Part 10 Determination of Permanent Change in Dimensions on Heating《密封成型耐火制品检验方法 第10部分 温度影响后恒定长度变化的测定》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Methods of test for dense shaped refractory products Part 10. Determination of permanent change in dimensions on heating The European Standasd EN 993-10 : 1997 has the status of a British Standard ICs 81.080 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGm LAW Bq m
2、BS EN 993-10 : 1998 BS 1902-5.10 : 1998 BS EN 993-10 1998 This British Standard, having been prepared under the direction of the Sector Board for Materials and Chemicals, was pubiished under the auhority of the Sandards Board and comes into effect on 15 March 1998 Q BSI 1998 National foreword This B
3、ritish Standard is the English language version of EN 99MO : 1997 published by the European Committee for Stan-on (CEN). It supeM EN 99310 November 1997 ICs 81.080 Descriptors: Refractory materials, shaped refractories, dense shaped refractory products, tests, thermal tests, determination, dimension
4、al stability, procedure English version Methods of test for dense shaped fkactory products - Part 10 Determination of pemnanent change in dimensions on heatirg Mthodes dessai pour produits rfractaires Parie 10 Dtermimion de la variation permanente de dimensions sous laction de la chaleur prufverfahr
5、en fr dichte gefonnte feuerfeste Teil 10 Bestimmung der bleibenden Langennderung nach Temperatureinwirkung faconns denses - Erzeugnisse- This European Standard was approved by CEN on 16 October 1997. CEN members are bound to comply with the CENKENELEC Internal Regulations which stipdate the conditio
6、ns for giving this European Standard the status of a national standard without any Ateration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three offi
7、cial versions (English, French, Gem). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Bel
8、gium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CEN European Committee for Standarduation Comit Europen de Normalisation Europisches Komitee fb- Normung Centrai Secreta
9、riat: rue de Stassart 36, 5-1060 Brussels O 1997 All rights of reproduction and communication in any form and by any means reserved to CEN and its members Ref. No. EN 993-10 : 1997 E STD=BSI BS EN 793-1O-ENGL 1798 lbZqbb7 Ob88518 793 W Page 2 EN 993-10 : 1997 Foreword Contents This European Standard
10、 has been prepared by Technical Commit m O O N I = 100 I* + I I + I 0 20 a- rR6 Detail of rounding-off studs, point of dial gauge and locating pins Dimensions in millimetres Q Carrier (see figure 2) Basepplate Figure 1. Length-measuring device (Method 1) (Plan view) O BSI 1998 * rn * 6 kst pieces Th
11、e number of items tested and the number of test pieces per item, shall be by agreement between the parties. NOTE 1. It is recommended that only one test piece should be taken from each item. Test pieces shaU be in the form of either: a) rectangular prisms, 50 mm X 50 mm X 60 mm; or b) cylinders, 50
12、mm diameter and 60 mm long. Tolerances on all dimensions shal be 2mm. Page 5 EN 993-10 : 1997 7.2.3 Volume measurement (Method 3) Determine the bulk density of the test piece in accordance with EN 993-1. Calculate the bulk volume, VB, in cubic centimetres, from the measurements taken, using the foli
13、owing equation: where NOTE 2. The 60 nun dimension should coincide with the direction of the forming pressure during manufacture if this direction is known. mi is the apparent mass of the immersed test piece in-; The position of each test piece in the brick shail be m2 is the mass of the soaked test
14、 piece in grams; recorded. The 50 mm X 50 mm faces of the prism, or the ends of the cylinder, shall be ground plane and parallel before the test. Each test piece shall be miq is the density of the immersion liquid in grams per cubic centimetre. identified by appropriate markjng. 7 Procedure 7.1 Dryi
15、ng of the test pieces Dry each test piece in the drying oven (6.6) at (i10 5) OC to constant mass. 7.2 Measurement of test pieces 7.2.1 Linear measurement by dial gauge apparatus (Method 1) Calibrate the length-measuring device (6.4) using the cylinder of known length. Place the test piece on the ca
16、rrier, with the 60 mm dimension vertical. For rectangular test pieces, align one corner with the diagonal mark on the carrier, and mark this corner so that the test piece may be placed in the same position for measurement after firing. Mark cylindrical test pieces adjacent to the diagonal mark. Meas
17、ure the length of the test piece in four positions, to an accmy of 0,Ol mm, by moving the carrier with the test piece over the base plate. For redangular test pieces, the four positions are located on the diagonals, between 20 mm and 25 mm from each corner. For cylindrical test pieces, the positions
18、 are 10 mm to 15 mm from the perimeter, on two diameters at right angles. Record each measuring point. 7.2.2 Linear measurement bg vernier callipers (Method 2) Measure the length of the test piece using the vernier calhpers (6.4.3) to an accuracy of 0,02 mm. Measure the length at three positions usi
19、ng the measuring points shown in figure 3. Mark the positions at which the measurements are made, either with refractory paint or by cutting small grooves across the edges of the test pieces (see figure 3). NOTE. Sliding test pieces in and out of the jaws of callipers can lead to wear of the surface
20、 of the jaws, although such an effect will be reduced because the length change is calculated by the difference of two measurements made with the same callipers. To minimize such wear, the test pieces should be placed carefully in the open jaws in contact with the upper fixed jaw, and the lower jaw
21、moved up until contact is made. 7.3 Mounting of test pieces in the furnace Place the test pieces in the furnace (6.1), each one resting on one of its 50 mm X 50 mm faces (for prisms) or on end (for cylinders), and protected from direct radiation in an electricaily heated fumace or from the fame of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN993101997ENMETHODSOFTESTFORDENSESHAPEDREFRACTORYPRODUCTSPART10DETERMINATIONOFPERMANENTCHANGEINDIMENSIONSONHEATING

链接地址:http://www.mydoc123.com/p-713101.html