ECA TEP105-1981 Industrial Cathode Ray Tube Test Methods《工业阴极射线管测试方法》.pdf
《ECA TEP105-1981 Industrial Cathode Ray Tube Test Methods《工业阴极射线管测试方法》.pdf》由会员分享,可在线阅读,更多相关《ECA TEP105-1981 Industrial Cathode Ray Tube Test Methods《工业阴极射线管测试方法》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、oc-, n EIA TEPLOS BL W 3234600 0007Z70 4 W - FEBRUARY 1981 INDUSTRIAL CATHODE RAY TUBE TEST METHODS FORMULATED BY EIA TUBE ENGINEERING PANEL ADVISORY COUNCIL (TEPAC) TEPAC PUBLICATION No. 105 . - - - I _ - EIA TEP305 81 m 323Yb00 0007293 b m Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering
2、 Department 2001 Eye Street, N.W., Washington, D.C. 20006 PRICE: $5.00 I EIA TEPLOS BL H 3234b00 0007292 B W INDUSTRIAL CATHODE RAY TUBE TEST METHODS TEPAC PUBLICATION NO. 105 This pub1 ication was formulated under the cognizance of the JT-20 Committee on Electro-Optic Devices and approved by the Tu
3、be Engineering Panel Advisory Counci 1 (TEPAC) PREFACE This publication includes all test methods developed by the JT-20 Committee on Electro-optic Devices for use in testing industrial cathode ray tubes, They are intended to be useful in evaluating cathode ray tubes with respect to parameters which
4、 are of interest to users of these devices. Included in the industrial CRT test methods is the measurement of control electrode voltages (previously issued as TEPAC Pub1 ication No. 97). This publication was compiled by the JT-6.16 Subcommittee on Industrial and Commercial Cathode Ray Tubes and appr
5、oved by the JT-6 Committee on Cathode Ray Tubes and the JEDEC Electron Tube Council, the test methods for industrial CRTS available in one document. e Its inclusion here makes all It is expected that as additional test methods become available, they will be incorporated into future additions to TEPA
6、C Publication 105. It is also expected that, at an appropriate time in the future, this material will be forwarded to the U.S. National Committee (USNC) of the IEC as a proposed revision, in part, of IEC 151-14. -1 - !EIA TEPL05 81 3234600 0007293 T * TEPAC PUBLICATION NO. 105 INDUSTRIAL CATHODE RAY
7、 TUBE TEST METHODS TABLE OF CONTENTS Page TEST METHOD 105-1 MEASUREMENT OF CONTROL ELECTRODE VOLTAGES IN CATHODE RAY TUBE$ . 3 TEST METHOD 105-2 METHOD OF TEST FOR CRT RASTER LUMINANCE 5 TEST METHOD 105-3 METHOD FOR MEASUREMENT OF LINE WIDTH BY THE SHRINKING RASTER METHOD (SRM) . 7 TEST METHOD 105-4
8、 METHOD OF TEST FOR PATTERN DISTORTION . 9 TEST METHOD 105-5 METHOD FOR MEASURING SPOT POSITION . 12 TEST METHOD 105-6 METHOD FOR MEASURING SPURIOUS ILLUMINATION . 14 EIA TEPLOS BL m 3234b00 O007294 L m 1. 1.1 1.2 1.3 1.4 1.5 2. 2.1 Def i n TEST METHOD 105-1 MEASUREMENT OF . CONTROL ELECTRODE VOLTAG
9、ES IN CATHODE RAY TUBES t ,ans Cutoff The cutoff of a CRT is the level of operation below which its output is effectively zero. Cutoff is established by visual extinction of a focused spot (Spot Cutoff), visual extinction of a focused raster of specified size (Raster Cutoff), or a specified Low Cath
10、ode Current Level. cut Off A CRT is cut off when operating at or below the cutoff level. Cutoff Vol tage Cutoff voltage is the voltage between grid and cathode necessary to achieve cutoff; i .e. cathode cutoff, grid 1 voltage relative to cathode for grid 1 cutoff or grid 2 voltage relative to cathod
11、e (unless otherwise stated) for grid 2 cutoff. cathode vol tage relative to grid 1 for Cathode Drive (Modulation) Vol tage The difference between the cathode-grid vol tage required for cutoff and that required for a specified luminance or cathode current. Grid Drive (Modulation) Voltage The differen
12、ce between the grid-cathode vol tage required for cutoff and that required for a specified luminance or cathode current. Test Methods Cutoff Vol tage With all electrode voltages and other operating parameters as speci- fied, adjust and measure the voltage applied to the specified current-regulating
13、electrode (cathode, grid 1 or grid 2) to achieve cutoff. EIA TEPLOS 81 W 3234b00 O007295 3 W 2.2 2.2.1 2.2.2 105-1 Precautions 1. In the measurement of spot cutoff, care must be taken to avoid damage to the screen. It is suggested that current be reduced , to near extinction of a focused raster befo
14、re removing scanning, 2. Unwanted deflections of the beam must be avoided. 3. In the measurement of raster cutoff, scanning must be linear to avoid bright areas. In the measurement of both spot and raster cutoff, light inci- dent on the tube face must be below a specified level. 4. 5. In the measure
15、ment of both spot and raster cutoff in CRTs with very long persistence it may be necessary to use a “cut on“ rather than a “cut off“ technique. In the measurement of cutoff to a predetermined current level, care must be taken to distinguish between beam current and leak- 6. age currents. Modulation
16、Voltages Measurement of Grid Drive (Modulation) Vol tage With all operating conditions as specified, raise the grid voltage from the cutoff value toward the cathode voltage until the specfied luminance or cathode current is achieved. The change in voltage is the grid drive (modulation) voltage. Meas
17、urement of Cathode Drive (Modulation) Vol tage With ail operating conditions as specified, reduce the cathode vol- tage from the cutoff value toward the grid voltage until the speci- fied luminance or cathode current is achieved. is the cathode drive (modulation) vol tage. The change in voltage -4-
18、EXA TEP105 81 m 323qb00 0007296 5 m TEST METHOD 105-2 METHOD OF TEST FOR CRT RASTER LUMINANCE 1. Purpose This method measures the luminous output from the face 0f.a CRT. 2. Test Equipment 2.1 Power supplies meeting the vol t.ages, currents and regulation speci- fied shall be used. 2.2 A calibrated l
19、uminance meter with spectral response closely matched to the CIE photopic curve (response of the average human eye), having sensitivity ranges compatible with the light levels anticipated and calibrated in nits (candelas/meter2) shall be used. of the photometer shall be +5% or better. may also be us
20、ed. A meter for monitoring the total accelerating potential between the cathode and screen with an accuracy of Il% or better shall be used. A meter for monitoring the total beam current delivered to the screen The accuracy (Footlambert calibration Multiply by 3.426 to obtain nits (candelas/meter2) 2
21、.3 O 2.4 with an accuracy of cl% or better shall be used. may be used for CRTs not suitable for measuring beam current.) (Cathode current 2.5 For these measurements a generator capable of producing a raster of 60 frames per second and 100 or more lines shall be used unless otherwise specified. The g
22、enerated raster shall have non1 ineari ty not greater than 5% along each axis. Retrace blanking shall not be area of the raster and large enough to include at least 10 scanning lines. . used. The fieid of view of the photometer should be smaller than the 3. Test Procedure 3.1 The CRT operating condi
23、tions shall be stated. i ncl uded . The following shall be O 31.1 i The incident illumination on the CRT face. EIA TEPLOS BL 3234600 0007297 7 = 105-2 The dimensions of the raster. (The shrinking raster method (SRM) may be used to obtain a measure of the highlight luminance of the written line. sinc
24、e the raster height is automatically satisfied by the me,rger conditions. Focused or defocused. Def 1 ecti on waveform. Location of measurement, Accelerating potential and beam current or equivalents, Vertical and horizontal scan rates. In this case only the raster width should be stated Precautions
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECATEP1051981INDUSTRIALCATHODERAYTUBETESTMETHODS 工业 阴极射线管 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-704584.html