1、 EIA STANDARD TP-29C Contact Retention Test Procedure for Electrical Connectors EIA-364-29C (Revision of EIA 364-29B) August 2006 EIA-364-29C ANSI/EIA-364-29C-2006 (R2013) Approved: August 14, 2006 Reaffirmed: January 28, 2013 NOTICE EIA Engineering Standards and Publications are designed to serve t
2、he public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standard
3、s and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whe
4、ther the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obl
5、igation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IE
6、C document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of re
7、gulatory limitations before its use. (From Standards Proposal No. 4945 formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards and reaffirmed per Standards Proposal No. 5252.06). Published by Electronic Components Industry Association 2013 Engineering D
8、epartment 2214 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For i
9、nformation, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) i Clause 1 CONTENTS Introduction .Page11.1 Scope . 11.2 Object 12 Test resources . 12.1 Equipment . 13 Test specimen 23.1 Description 23.2 Preparation 24 Test
10、 procedure . 24.1 General 24.2 Method A - Test to specified force without displacement measurement . 34.3 Method B - Test to specified force with displacement measurement 44.4 Method C - Test to destruction . 45 Details to be specified . 46 Test documentation . 5Figure 1 Force application contact al
11、ignment fixture . 3ii (This page left blank) EIA-364-29C Page 1 TEST PROCEDURE No. 29C CONTACT RETENTION TEST PROCEDURE FOR ELECTRICAL CONNECTORS (From EIA Standards Proposal No. 4945, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and was previously published
12、in EIA-364-29B.) 1 Introduction 1.1 Scope This standard establishes a test method to impose axial forces on the connector contacts to determine the ability of the connector to withstand forces that tend to displace contacts from their proper location within the connector insert and resist contact pu
13、llout. These forces may be the result of: loads on wire connected to the contacts; forces required to restrict contact push-through during assembly of removable type contacts into connector inserts; forces produced by mating contacts during connector mating; dynamic forces produced by vibration and
14、shock during normal use of the connectors; forces relating to bundling strains on the wire. 1.2 Object The object of this test procedure is to detail a standard method to assess the ability of the contact retaining system to withstand the axial mechanical stresses likely to be encountered during nor
15、mal usage. 2 Test resources 2.1 Equipment The test equipment shall consist of: 2.1.1 Force gauges, of suitable range for the contact size under test, so that readings will be in the middle 50% of the scale, where practical, with a nominal full scale accuracy of 2%. EIA-364-29C Page 2 2.1.2 Dial indi
16、cator gauges, or other suitable instruments of such range for the contacts under test that the readings will be in the middle 50% of the scale, with a nominal full scale accuracy of 2%. 2.1.3 Suitable compression device (such as an arbor press). 2.1.4 Steel test probes to adapt the force gauge plung
17、er to the particular contact (pin, socket, hermaphroditic) front or wiring end under test. 2.1.5 Contact insertion and removal tools, as required. 3 Test specimen 3.1 Description The specimen shall consist of a plug or receptacle with all contacts in place. 3.2 Preparation 3.2.1 All backshell hardwa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36429C2006TP29CCONTACTRETENTIONTESTPROCEDUREFORELECTRICALCONNECTORSPDF

链接地址:http://www.mydoc123.com/p-704249.html