DLA SMD-5962-93073 REV F-2012 MICROCIRCUIT HYBRID LINEAR +5 AND PLUS MINUS 12-VOLT TRIPLE CHANNEL DC DC CONVERTER.pdf
《DLA SMD-5962-93073 REV F-2012 MICROCIRCUIT HYBRID LINEAR +5 AND PLUS MINUS 12-VOLT TRIPLE CHANNEL DC DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-93073 REV F-2012 MICROCIRCUIT HYBRID LINEAR +5 AND PLUS MINUS 12-VOLT TRIPLE CHANNEL DC DC CONVERTER.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R005-96. 95-10-18 K. A. Cottongim B Figure 1, dimension table, symbol q: inches column, change 1.950 BSC to 1.950 maximum and millimeters column, 49.53 BSC to 49.53 maximum. Table I, delete note 4 from output c
2、urrent test (IOUT) and notes following table I. Renumber remaining notes in sequence. Redrew entire document. -sld 98-02-02 K. A. Cottongim C Changed the max limit for the input ripple current test (IRIP) for subgroup 1 from 40 mA p-p to 45 mA p-p. Table I; Changed in footnote three “At least 100 mA
3、“ to “At least 300 mA“. -sld 98-07-07 K. A. Cottongim D Table I, VRLOAD, conditions column, change IOUT= 0 to 4 A (main) to IOUT= 300 mA to 4 A (main). Table I, note 3 changed. 99-10-20 Raymond Monnin E Update drawing boilerplate. Editorial changes throughout. 03-07-18 Raymond Monnin F Added footnot
4、e 1 to table II, under group C end-point electricals. Updated drawing paragraphs. -sld 12-04-10 Charles F. Saffle REV SHEET REV SHEET REV STATUS REV F F F F F F F F F F F OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http
5、:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY Michael C. Jones APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, +5 AND 12-VOLT, TRIPLE CHANNEL, DC/DC CONVERTER DRAWI
6、NG APPROVAL DATE 95-06-15 AMSC N/A REVISION LEVEL F SIZE A CAGE CODE 67268 5962-93073 SHEET 1 OF 11 DSCC FORM 2233 APR 97 5962-E164-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93073 DLA LAND AND MARITI
7、ME COLUMBUS, OHIO 43218-3990 REVISION LEVEL F SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Iden
8、tifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 93073 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.
9、1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1
10、.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 MTR28512T/883, MTR28512TF/883 DC-DC converter, 30 W, +5 V and 12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying
11、the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest rel
12、iability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level
13、uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the
14、other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D M
15、anufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Termi
16、nals Package style X See figure 1 10 Dual-in-line Z See figure 1 10 Flange mount Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93073 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL F SHEET 3
17、DSCC FORM 2234 APR 97 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range (VIN) -0.5 V dc to +50 V dc Power dissipation (PD) . 14 W Output power . 30.84 W Lead soldering temperature (10 seconds) . +300 C Storage temperature
18、range -65 C to +150 C 1.4 Recommended operating conditions. Input voltage range (VIN) +16 V dc to +40 V dc Output currents: +5 V (main) . +4000 mA 12 V (dual) 416 mA Output power 2/ 3/ . 30 W Case operating temperature range (TC) . -55 C to +125 C 2. APPLICABLE DOCUMENTS 2.1 Government specification
19、, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 -
20、 Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDB
21、K-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict betwe
22、en the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent dama
23、ge to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Derate output power linearly above case temperature +125 C to 0 at +135 C. 3/ At least 5 percent of total power should be from the main (+5 volt) output. Provided by IHSNot for ResaleNo repr
24、oduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-93073 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL F SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596293073REVF2012MICROCIRCUITHYBRIDLINEAR5ANDPLUSMINUS12VOLTTRIPLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700285.html