DLA MIL-HDBK-780 D CHANGE 1-2012 STANDARD MICROCIRCUIT DRAWINGS.pdf
《DLA MIL-HDBK-780 D CHANGE 1-2012 STANDARD MICROCIRCUIT DRAWINGS.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-HDBK-780 D CHANGE 1-2012 STANDARD MICROCIRCUIT DRAWINGS.pdf(47页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-HDBK-780D w/Change 1 6 January 2012 SUPERSEDING MIL-HDBK-780D 28 May 2004 DEPARTMENT OF DEFENSE HANDBOOK STANDARD MICROCIRCUIT DRAWINGS This handbook is for guidance only. Do not cite this document as a requirement. AMSC N/A FSC 5962 NOT MEASUREMENT SENSITIVE Provided by IHSNot for ResaleNo rep
2、roduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 ii FOREWORD 1. This handbook is approved for use by all Departments and Agencies of the Department of Defense. 2. This handbook provides guidance on standard microcircuit drawings (SMDs). The purpose of the SMD p
3、rogram is to minimize the proliferation of specification and source control drawings within the Department of Defense (DoD). The use of one SMD for an item of supply in use by DoD Departments and Agencies is the objective of this program. 3. It is intended that the issue of SMDs affect DoD procureme
4、nt through minimizing the proliferation of duplicate drawings for an item of supply. 4. It is also the objective of the SMD Program that the resulting drawing be multi-user in actual implementation. 5 The application of this handbook is currently confined to the acquisition of microcircuits until su
5、ch time that applicability to federal supply classes other than FSC 5962 is deemed appropriate. 6. Comments, suggestions, or questions on this document should be addressed to Commander, Defense Logistics Agency, DLA Land and Maritime, ATTN: VA, P. O. Box 3990, Columbus, OH 43218-3990 or emailed to S
6、TD1835dla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/. SUMMARY OF CHANGE 1 MODIFICATIONS 1. References to MIL-HDBK-512 has been changed to MIL-STD-3018, which supersedes it.
7、 2. References to MIL-STD-1835 and SD-19 have been added. 3. References to ASME Y14.5M has been changed to ASME Y14.5, which supersedes it. 4. The organization notated as ASME has been changed from American Society of Mechanical Engineers to ASME International to reflect the current name. 5. Section
8、 2, and throughout, the web address for acquiring government specifications and standards has been changed to the current address for the Assist online services. 6. Section 4.2.5.5, Classification of conformance inspections has been edited to include Group E which was missing. 7. In various location
9、s, Defense Supply Center Columbus has been changed to DLA Land Maritime to reflect the current name. 8. Figures 1-6 has been changed to reflect current boiler plates. 9. Where applicable, changes were made to comply with MIL-STD-967 for preparation of a military handbook. * * * * Provided by IHSNot
10、for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 iii CONTENTS PARAGRAPH PAGE 1. SCOPE 1 1.1 Scope 1 2. APPLICABLE DOCUMENTS 1 2.1 General . 1 2.2 Government documents 1 2.2.1 Specifications, standards, and handbooks 1 2.2.2 Other Government docu
11、ments, drawings, and publications 1 2.3 Non-Government publications . 1 2.4 Order of precedence . 2 3. DEFINITIONS . 2 3.1 Standard microcircuit drawing . 2 3.2 General specification . 2 3.3 Military Parts Control Advisory Group (MPCAG) . 2 4. GENERAL GUIDANCE . 2 4.1 Introduction . 2 4.2 Sectional
12、arrangement of an SMD 2 4.2.1 Subject matter . 2 4.2.2 Section 1 2 4.2.2.1 Scope . 2 4.2.2.2 Part or Identifying Number (PIN) . 2 4.2.3 Section 2 . 3 4.2.3.1 Listing of references 3 4.2.3.1.1 Government documents 3 4.2.3.1.2 Nongovernment standards and other publications 4 4.2.3.1.3 Order of precede
13、nce . 4 4.2.4 Section 3 . 4 4.2.4.1 Requirements 4 4.2.4.1.1 Organization of requirements 5 4.2.4.1.2 Sequencing of requirements and tests 5 4.2.4.2 Materials 5 4.2.4.3 Design . 5 4.2.4.4 Construction 5 4.2.4.5 Hardware . 5 4.2.4.6 Performance characteristics 5 4.2.4.7 Dimensions 6 4.2.4.8 Finish .
14、6 4.2.4.9 Marking . 6 4.2.4.10 Selection of alternative materials, construction, etc. 6 4.2.4.11 Certificate of compliance . 6 4.2.4.12 Certificate of conformance . 6 4.2.4.13 Notification of change or discontinuance . 6 * Provided by IHSNot for ResaleNo reproduction or networking permitted without
15、license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 iv CONTENTS PARAGRAPH PAGE 4.2.4.14 Verification and review 6 4.2.5 Section 4 . 6 4.2.5.1 Quality assurance provisions . 6 4.2.5.2 Responsibility for inspection 6 4.2.5.3 Responsibility for compliance 7 4.2.5.4 Conformance inspection 7 4.2.5.4.1 Conforma
16、nce inspection sampling . 7 4.2.5.5 Classification of conformance inspections . 7 4.2.5.6 Tabular listing of conformance inspection . 8 4.2.6 Section 5 . 8 4.2.6.1 Packaging, packing, and marking 8 4.2.7 Section 6 . 8 4.2.7.1 Notes . 8 4.2.7.2 Intended use 8 4.2.7.3 Comments . 8 4.2.7.4 Sources of s
17、upply 8 4.3 Approved SMDs 9 4.3.1 SMD user 9 4.3.2 Changes to SMDs 9 4.3.3 Nonconcurrence with proposed changes 9 5. DETAILED GUIDANCE . 9 5.1 Introduction 9 5.2 Drawing preparation 9 5.3 Initial drawing preparation . 9 5.3.1 Blank drawings 9 5.3.2 SMD coordination 9 5.3.3 Preliminary and final draf
18、t submittal . 9 5.3.3.1 Preliminary draft construction 9 5.3.4 Maintenance 9 5.3.5 SMD content preparation . 9 5.3.5.1 Section 1, scope 9 5.3.5.1.1 Scope 9 5.3.5.1.2 PIN 9 5.3.5.1.2.1 PIN length 10 5.3.5.1.3 Radiation hardness assurance (RHA) Designator . 10 5.3.5.1.4 Device type(s) . 10 5.3.5.1.5 D
19、evice class designator . 10 5.3.5.1.6 Case outline 10 5.3.5.1.7 Lead finish . 10 5.3.5.1.8 Absolute maximum ratings 10 5.3.5.1.9 Recommended operating conditions . 10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 v CONTENTS
20、 PARAGRAPH PAGE 5.3.5.2 Section 2, applicable documents 10 5.3.5.2.1 Order of precedence 10 5.3.5.3 Section 3, requirements . 10 5.3.5.3.1 Item requirements 10 5.3.5.3.2 Design, construction and physical dimensions . 10 5.3.5.3.3 Terminal connections . 10 5.3.5.3.4 Block diagram 11 5.3.5.3.5 Truth t
21、ables 11 5.3.5.3.6 Case outline(s) . 11 5.3.5.3.7 Electrical performance characteristics and post irradiation parameter limits . . 11 5.3.5.3.8 Electrical test requirements 11 5.3.5.3.9 Marking 11 5.3.5.3.10 Tables 11 5.3.5.3.11 Graphics . 11 5.3.5.3.12 Certificate of compliance 11 5.3.5.3.13 Certif
22、icate of conformance . 11 5.3.5.3.14 Notification of change . 11 5.3.5.3.15 Verification of change . 11 5.3.6 Section 4, verification . 12 5.3.6.1 Sampling and inspection 12 5.3.6.2 Screening . 12 5.3.6.3 Qualification inspection 12 5.3.6.4 Conformance inspection 12 5.3.6.4.1 Group A inspection . 12
23、 5.3.6.4.2 Group C inspection 12 5.3.6.4.3 Group D inspection 12 5.3.6.4.4 Group E inspection . 12 5.3.6.5 Tables, electrical tests 12 5.3.7 Section 5, packaging 12 5.3.7.1 Packaging requirements 12 5.3.8 Section 6, notes . 12 5.3.8.1 Intended use 12 5.3.8.1.1 Replaceability . 12 5.3.8.1.2 Substitut
24、ability 13 5.3.8.2 Configuration control of SMDs . 13 5.3.8.3 Record of users 13 5.3.8.4 Comments 13 5.3.8.5 Abbreviations, symbols, and definitions . 13 5.3.8.6 Sources of supply . 13 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILHDBK780DCHANGE12012STANDARDMICROCIRCUITDRAWINGSPDF

链接地址:http://www.mydoc123.com/p-691423.html