《DLA MIL-DTL-83522 16 C-2013 CONNECTOR FIBER OPTIC SINGLE TERMINUS PLUG BAYONET COUPLING (ST STYLE) 2 5 MILLIMETERS DIAMETER FERRULE EPOXY.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-83522 16 C-2013 CONNECTOR FIBER OPTIC SINGLE TERMINUS PLUG BAYONET COUPLING (ST STYLE) 2 5 MILLIMETERS DIAMETER FERRULE EPOXY.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-DTL-83522/16C 28 June 2013 SUPERSEDING MIL-C-83522/16B 11 May 1995 DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC, SINGLE TERMINUS, PLUG, BAYONET COUPLING (ST STYLE), 2.5 MILLIMETERS DIAMETER FERRULE, EPOXY This specification is approved for use by all Depart- ments and Agencies of the Depar
2、tment of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-83522. AMSC N/A FSC 6060 METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83522/16C 2 mm 0.32 2.0 3.3 19
3、.1 Inches .0126 .08 .13 .75 1.50 FIGURE 1. Dimensions and configuration Continued. Letter Millimeters Inches Notes Min Max Min Max A (MM/SM) 2.4985 2.4995 0.09837 0.09841 3 A (MM) 2.498 2.500 0.0983 0.0984 3 B 5.25 5.38 0.207 0.212 C 0.91 1.07 0.036 0.042 D 7.06 min 0.278 min E 7.75 8.00 0.305 0.315
4、 F 2.56 4.50 0.101 0.177 G 0.58 0.89 0.023 0.035 H 1.60 min 0.063 min J 9.40 9.80 0.370 0.386 L 2.00 2.00 0.079 0.079 4 M 0.64 1.12 0.025 0.044 N 8.56 min 0.337 min 5 Q 1.04 1.60 0.041 0.063 R (MM/SM) 8 25 0.3 1.0 6 R (MM) 8 min 0.3 min 6 X (MM/SM) 0.020 0.063 0.0008 0.0025 7 X (MM) 0.000 0.063 0.00
5、00 0.0025 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83522/16C 3 NOTES: 1. Dimensions are in millimeters. 2. Inch equivalents are given for general information only. 3. Use A (SM/MM) for single mode applications. Use A (SM/MM) or A (MM
6、) for multimode applications. 4. L dimensions is the diameter of a circle on the surface of the ferrule that is concentric with the axis of the ferrule. 5. Design optional. 6. R dimension is for reference of conceptual design considerations only. This dimension is the radius of the end of the ferrul
7、e when the surface of the ferrule is spherical, and L is as given. 7. X dimension is the distance that the apex of the end of the ferrule extends beyond the circle described in note 4. 8. a angle to be between 20 and 35. Part or Identifying Number (PIN) is a new term encompassing previous terms used
8、 in specifications such as part number, type designator, or identification number and is as follows: M83522/16 X X X X Configuration: A (locking boot, long cap) Configuration D (nonlocking boot, either long or short cap) E (protective cover) F (90 degree boot, either long or short cap) Temperature T
9、emperature: H (high) N (normal) Fiber size Fiber size: X (type I) (125 m, MM) Y (type II) (125 m, MM/SM) Z (type I) (140 m, MM) Additional Additional consideration: considerations S qualified to space flight requirements NOTE: Cap refers to the bayonet cap or ST connector outside metal housing. Barr
10、el refers to interior metal part that supports the ferrule and crimp sleeve. REQUIREMENTS: Metals: The plug housing and other metal components shall be of corrosion resistant steel in accordance with SAE-QQ-S-763, class 303/316L or ASTM A-276, designation S31803, or nickel-plated brass, alloy 345 or
11、 360, in accordance with ASTM B-16/B16M. Ferrule material: Ceramic (zirconia). The dust cover, strain relief boot, and protective cap shall be made of thermoplastic or fluorosilicone. Epoxies: Use an epoxy approved by the qualifying activity. Dimensions and configuration: See figure 1. Fiber optic c
12、able requirements: Cable configuration: In accordance with MIL-PRF-85045. Fiber diameter: 50/125 m, 62.5/125 m, and 100/140 m, with the following respective tolerances: 125 2 m (MM), 125 1 m (MM/SM), 140 2 m (MM). Provided by IHSNot for ResaleNo reproduction or networking permitted without license f
13、rom IHS-,-,-MIL-DTL-83522/16C 4 Fiber optic contact: Method optical alignment: Sleeve/ferrule. Lens configuration: Not applicable. Coating requirements: Not applicable. Nuclear radiation resistance: Not applicable. Weight: 20 grams maximum. Polarization: Key/slot. Safety wire holes: Not required. Fo
14、rce to engage and disengage: Longitudinal force: Not applicable. Torque: Not applicable. Lubricants: Not applicable. Water submersion: Not applicable. Coupling proof torque: Not applicable. Coupling mechanism retention force: Not applicable. Tensile loading: The load shall be 230N minimum and shall
15、not result in any physical damage. Optical properties shall be monitored before and after load. The load shall not be applied to the coupling mechanism. Optical transmittance measurements are not required during the test for the non-locking connectors. Dust (fine sand): Applicable. Perform as specif
16、ied in the requirements of MIL-DTL 83522 with the following modifications: a. The connectors shall not be rotated during steps 1 and 3. Each connector shall be oriented in the chamber such that the key slot is in line with the oncoming air flow. The connectors shall be affixed in such a manner that
17、the orientation of the connector does not change throughout the duration of the test. b. The change in optical transmittance shall be measured before the dust test, during the 6 hour exposure period of step 1, before step 3, during the 6 hour exposure period of step 3, and after the test. Samples sh
18、all be visually examined, after cleaning, at the conclusion of the dust test. Ozone exposure: Not applicable. High impact shock: Applicable to single mode and multimode locking and non-locking connectors. Fluid immersion: Not applicable. Residual magnetism: Not applicable. Shock: For SM/MM connector
19、s assemble on single mode fiber, signal discontinuity is applicable during shock except that the duration for blows to the three axes are relaxed to a maximum of 1 second. For MM non-locking connectors and SM/MM connectors assemble on multimode fiber, signal discontinuity is applicable during shock
20、except that the duration for blows to the side axis are relaxed to a maximum of 500 microseconds. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-83522/16C 5 Plug accessories: Each plug shall be packaged with a minimum of one crimp ferrule, o
21、ne dust cover, and one strain relief boot. Protective cover: The protective cover shall consist of a lanyard which attaches to the optical fiber cable and a cap for covering the connector (see figure 2). The protective cover shall be installable after the connector termination process is complete. T
22、he protective cover shall be subjected only to the temperature/humidity cycling and fungus tests. The protective cover shall not be provided with the plug connector. Crimp sleeve: The crimp sleeve shall accept single fiber cordage with a maximum outer diameter of 2.50 mm (.0984 inch). The plug conne
23、ctor shall meet all requirements when the crimp sleeve is assembled to the plug connector using one of the following: A hex crimp die measuring 4.84 mm .05 mm (.190 inch .001 inch) across the flats, a circular indent ring crimp die with a 2.67 mm .08 mm (.105 inch .003 inch) minor diameter and a 3.4
24、3 mm .08 mm (.135 inch .003 inch) major diameter, or a circular indent ring crimp die with a 2.29 mm .08 mm (.090 inch .003 inch) minor diameter and a 3.05 mm .08 mm (.120 inch .003 inch) major diameter. Boot color: Single mode boots are to be blue, 62.5/125 micron multimode boots are to be black 10
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL8352216C2013CONNECTORFIBEROPTICSINGLETERMINUSPLUGBAYONETCOUPLINGSTSTYLE25MILLIMETERSDIAMETERFERRULEEPOXYPDF

链接地址:http://www.mydoc123.com/p-691141.html