DLA MIL-DTL-49285 2 A-2009 CABLE SPECIAL PURPOSE ELECTRICAL FIFTEEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf
《DLA MIL-DTL-49285 2 A-2009 CABLE SPECIAL PURPOSE ELECTRICAL FIFTEEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-49285 2 A-2009 CABLE SPECIAL PURPOSE ELECTRICAL FIFTEEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-DTL-49285/2A INCH-POUND15 May 2009 SUPERSEDING MIL-C-49285/2 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, FIFTEEN INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG Inactive for new design after 16 June 1997.This specification is approved for use by all Departments
2、 and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr
3、om IHS-,-,-MIL-DTL-49285/2A Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with one conductor tied to the shie
4、ld Continuous working voltage Nominal capacitance between adjacent shields Continuous working voltage between adjacent shields Shield dc resistance 30 pF/ft (picofarads/foot) 55 pF/ft 300 V rms maximum between conductors 150 pF/ft 50 volts maximum 14 ohms/1,000 feet maximum TABLE II. Description, ph
5、ysical. Components Construction details Number of pairs Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thickness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile strength (jacke
6、t) Elongation (jacket) Overall cabling lay length Fifteen individually shielded Stranded tinned copper 22 AWG 7 X 30 AWG Polypropylene 0.010 inch nominal thickness Stranded tinned copper 22 AWG 16 X 34 AWG Polyvinyl chloride 0.050 inch 0.600 inch maximum outside diameter 2493 2,000 pounds per square
7、 inch minimum 150 percent minimum 1.3 twists per foot 10 percent Cabled pair orientation: The position of the red and green pair shield shall determine the rotation direction for pair location (see figure 1). 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
8、IHS-,-,-MIL-DTL-49285/2A TABLE III. Shield color code. Pair numbers Shield color Center core 1stpair 2ndpair 3rdpair 4thpair Outer layer 5thpair 6thpair 7thpair 8thpair 9thpair 10thpair 11thpair 12thpair 13thpair 14thpair 15thpair Red Green Blue 1 Blue 2 Red Green Blue 1 Blue 2 Blue 3 Blue 4 Blue 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL492852A2009CABLESPECIALPURPOSEELECTRICALFIFTEENINDIVIDUALLYSHIELDEDPAIRSOF227X30AWGPDF

链接地址:http://www.mydoc123.com/p-690838.html