DLA DSCC-DWG-89090 REV C-2002 CONNECTOR ELECTRICAL CIRCULAR PLUG STRAIGHT REMOVAL CRIMP CONTACTS SERIES III HYBRID CONSTRUCTION《环状直插针压接可拆触点连接器 系列III 混合建造》.pdf
《DLA DSCC-DWG-89090 REV C-2002 CONNECTOR ELECTRICAL CIRCULAR PLUG STRAIGHT REMOVAL CRIMP CONTACTS SERIES III HYBRID CONSTRUCTION《环状直插针压接可拆触点连接器 系列III 混合建造》.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-89090 REV C-2002 CONNECTOR ELECTRICAL CIRCULAR PLUG STRAIGHT REMOVAL CRIMP CONTACTS SERIES III HYBRID CONSTRUCTION《环状直插针压接可拆触点连接器 系列III 混合建造》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、REVISIONS LTR DESCRIPTION DATE APPROVED A Add source 06090. 28 Feb 91 Richard Marbais B Add dimension “Z”. Editorial changes throughout. 22 Sept 93 Randy Larson C Update format. Correcting references. Correcting address list of sources. 16 July 02 Robert Heber Prepared in accordance with ASME Y14.10
2、0 REV PAGE REV C C C C C C REV STATUS OF PAGES PAGE 1 2 3 4 5 6 PREPARED BY PMIC N/A Jeffery Tunstall DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43216-5000 CHECKED BY TITLE Abdo Abdouni APPROVED BY Robert Heber CONNECTOR, ELECTRICAL, CIRCULAR, PLUG, STRAIGHT, REMOVAL CRIMP CONTACTS, SERIES III,
3、HYBRID CONSTRUCTION SIZE CAGE CODE 037Z3 DWG. NO. 89090 Original date of drawing 21 Sept 89 A REV C PAGE 1 OF 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AMSC N/A 5935-E663 DISTRIBUTION STATEMENT A. Approved for public release; distribution is
4、unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 89090 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV C PAGE 3 FIGURE 1. Dimensions and configuration. Provided by IHSNot for ResaleNo reproduction
5、or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 037Z3 89090 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV C PAGE 4 Shell size Shell size code B dia S dia max Z max 9 A .732 .724 .858 1.220 11 B .839 .831 .984 1.220 13 C 1.008 1.000 1.157 1.220 15 D 1.138 1
6、.130 1.280 1.220 17 E 1.276 1.268 1.406 1.220 19 F 1.382 1.374 1.516 1.220 21 G 1.508 1.500 1.642 1.220 23 H 1.626 1.618 1.768 1.220 25 J 1.752 1.744 1.890 1.220 Inches mm Inches mm Inches mm Inches mm .060 1.52 .858 21.79 1.268 32.21 1.516 38.51 .070 1.78 .984 24.99 1.276 32.41 1.618 41.10 .169 4.2
7、9 1.000 25.40 1.280 32.51 1.626 41.30 .201 5.11 1.008 25.60 1.374 34.90 1.642 41.71 .724 18.39 1.130 28.70 1.382 35.10 1.744 44.30 .732 18.59 1.138 28.91 1.406 35.71 1.752 44.50 .831 21.11 1.157 29.39 1.500 38.10 1.768 44.91 .839 21.31 1.220 30.99 1.508 38.30 1.890 48.00 NOTES: 1. Dimensions are inc
8、hes. 2. Metric equivalents are given for general information only. 3. Metallic material inner shell must have solid surface through the length Z and inner circumference of the shell. 4. Undercut may me be incorporated to accept accessory configuration in accordance with MIL-DTL-38999, series III. 5.
9、 For details of connector front and rear end configuration, see MIL-DTL-38999, series III. 6. Metallic surfaces required for conductivity between plug receptacle; plug accessories. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO
10、. 037Z3 89090 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43216-5000 A REV C PAGE 5 FIGURE 1. Dimensions and configuration Continued. SCOPE This is an extended environment-resisting hybrid construction (metal sleeve in nonmetallic shell) connector. Metallic surfaces indicated on figure 1 are finish
11、ed with olive drab cadmium plate over a suitable underplate. Other surfaces are uncoated nonmetallic for corrosion resistance. REQUIREMENTS: Connectors shall meet the requirements of MIL-DTL-38999, series III, class W, with the following exceptions and additions. Dimension and configurations: See fi
12、gure 1. Interface dimensions shall confirm to MIL-DTL-38999. For insert arrangements: See MIL-STD-1560. Salt spray (corrosion): The wired, assembled connectors shall meet the dynamic salt spray requirements of MIL-DTL-38999, with the following exceptions: The connectors shall be tested 1052 hours ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG89090REVC2002CONNECTORELECTRICALCIRCULARPLUGSTRAIGHTREMOVALCRIMPCONTACTSSERIESIIIHYBRIDCONSTRUCTION

链接地址:http://www.mydoc123.com/p-688935.html