BS ISO 19685-2017 Vacuum technology Vacuum gauges Specifications calibration and measurement uncertainties for Pirani gauges《真空技术 真空计 皮拉尼仪表的规格、校准和测量不确定度》.pdf
《BS ISO 19685-2017 Vacuum technology Vacuum gauges Specifications calibration and measurement uncertainties for Pirani gauges《真空技术 真空计 皮拉尼仪表的规格、校准和测量不确定度》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 19685-2017 Vacuum technology Vacuum gauges Specifications calibration and measurement uncertainties for Pirani gauges《真空技术 真空计 皮拉尼仪表的规格、校准和测量不确定度》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Vacuum technology Vacuum gauges Specifications, calibration and measurement uncertainties for Pirani gaugesBS ISO 19685:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06 ISO 2017Vacuum technology Vacuum gauges Specifications, calibration and measurement uncertaint
2、ies for Pirani gaugesTechnique du vide Manomtres vide Spcifications, talonnage et incertitudes de mesure pour les jauges PiraniINTERNATIONAL STANDARDISO19685First edition2017-09Reference numberISO 19685:2017(E)National forewordThis British Standard is the UK implementation of ISO 19685:2017.The UK p
3、articipation in its preparation was entrusted to Technical Committee MCE/8/-/4, Vacuum technology.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are respo
4、nsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017ISBN 978 0 580 93829 0ICS 23.160Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards
5、Policy and Strategy Committee on 30 September 2017.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS ISO 19685:2017 ISO 2017Vacuum technology Vacuum gauges Specifications, calibration and measurement uncertainties for Pirani gaugesTechnique du vide Manomtres vide Spc
6、ifications, talonnage et incertitudes de mesure pour les jauges PiraniINTERNATIONAL STANDARDISO19685First edition2017-09Reference numberISO 19685:2017(E)BS ISO 19685:2017ISO 19685:2017(E)ii ISO 2017 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2017, Published in SwitzerlandAll rights reserved
7、. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at
8、 the address below or ISOs member body in the country of the requester.ISO copyright officeCh. de Blandonnet 8 CP 401CH-1214 Vernier, Geneva, SwitzerlandTel. +41 22 749 01 11Fax +41 22 749 09 47copyrightiso.orgwww.iso.orgBS ISO 19685:2017ISO 19685:2017(E)ii ISO 2017 All rights reservedCOPYRIGHT PROT
9、ECTED DOCUMENT ISO 2017, Published in SwitzerlandAll rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prio
10、r written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCh. de Blandonnet 8 CP 401CH-1214 Vernier, Geneva, SwitzerlandTel. +41 22 749 01 11Fax +41 22 749 09 47copyrightiso.orgwww.iso.orgISO 19685:2
11、017(E)Foreword ivIntroduction v1 Scope . 12 Normative references 13 Terms and definitions . 14 Symbols and abbreviated terms . 45 Principle of Pirani gauge 46 Specifications for Pirani gauge 56.1 General . 56.2 Measuring principle 56.3 Type of output . 56.4 Range of output and output display resolut
12、ion 56.5 Measurement range and full scale . 56.6 Expected measurement uncertainty 56.7 Material exposed to gas . 56.8 Connecting flange . 56.9 Interface and pin-connections . 66.10 Warm-up period 66.11 Compatibility between gauge tube and controller 66.12 Normal operating (environment) conditions .
13、66.13 Electrical power supply . 66.14 Cable length . 66.15 Maximum bake-out temperature 66.16 Dimensions of gauge head and controller . 66.17 Mounting orientation 67 Additional (optional) specifications for Pirani gauge . 67.1 Long-term instability . 67.2 Relative sensitivity factor . 77.3 Hysteresi
14、s 77.4 Response time 77.5 Inspection record and calibration certificate . 77.6 Configuration 77.7 Weight . 77.8 Storage and transport condition 77.9 Photographs 77.10 Maximum power consumption . 77.11 Set point of pressure 78 Calibration and other measurement procedures. 78.1 General . 78.2 Conditio
15、ns for calibrations . 88.3 Assembly and adjustments of calibration item . 88.4 Calibration 98.5 Measurement uncertainties during calibration 98.6 Calibration certificate 98.7 Measurement procedure for hysteresis . 108.8 Measurement procedure of response time 109 Measurement uncertainties at use .10A
16、nnex A (informative) Typical Pirani gauge 12Bibliography .13 ISO 2017 All rights reserved iiiContents PageBS ISO 19685:2017ISO 19685:2017(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of prepari
17、ng International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in lia
18、ison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Dir
19、ectives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).Attention is drawn to the possibility that s
20、ome of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent decla
21、rations received (see www.iso.org/patents).Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and expressions related to conformity as
22、sessment, as well as information about ISOs adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following URL: www.iso.org/iso/foreword.html.This document was prepared by Technical Committee ISO/TC 112, Vacuum technology.iv ISO 2017 All rights
23、reservedBS ISO 19685:2017ISO 19685:2017(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member b
24、ody interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO196852017VACUUMTECHNOLOGYVACUUMGAUGESSPECIFICATIONSCALIBRATIONANDMEASUREMENTUNCERTAINTIESFORPIRANIGAUGES

链接地址:http://www.mydoc123.com/p-585979.html