BS IEC 60076-15-2015 Power transformers Gas-filled power transformers《电力变压器 充气电力变压器》.pdf
《BS IEC 60076-15-2015 Power transformers Gas-filled power transformers《电力变压器 充气电力变压器》.pdf》由会员分享,可在线阅读,更多相关《BS IEC 60076-15-2015 Power transformers Gas-filled power transformers《电力变压器 充气电力变压器》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationPower transformersPart 15: Gas-filled power transformersBS IEC 60076-15:2015National forewordThis British Standard is the UK implementation of IEC 60076-15:2015.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/14, Power transformers.A list of o
2、rganizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2
3、015ISBN 978 0 580 81337 5ICS 29.180Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 2015.Amendments/corrigenda issued since publicationDate Text affectedBRI
4、TISH STANDARDBS IEC 60076-15:2015IEC 60076-15 Edition 2.0 2015-04 INTERNATIONALSTANDARD NORMEINTERNATIONALE Power transformers Part 15: Gas-filled power transformers Transformateurs de puissance Partie 15: Transformateurs de puissance isolation gazeuse INTERNATIONALELECTROTECHNICALCOMMISSION COMMISS
5、IONELECTROTECHNIQUEINTERNATIONALE ICS 20.180 ISBN 978-2-8322-2626-1 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electrotechnique Internationale Warning! Make sure that you obtained this publication from an authorized distributor. Attention! Veu
6、illez vous assurer que vous avez obtenu cette publication via un distributeur agr. 2 IEC 60076-15:2015 IEC 2015 CONTENTS FOREWORD . 4 1 Scope 6 2 Normative references. 6 3 Terms and definitions 7 3.5 Terms, definitions, symbols and units relating to gas and vacuum tightness . 8 4 Service conditions
7、. 8 5 Rating and general requirements . 8 5.1 Rated power . 8 5.1.1 General . 8 5.1.2 Preferred values of rated power 9 5.1.3 Minimum power under alternative cooling modes 9 5.1.4 Loading beyond rated power 9 5.2 Cooling mode 9 5.2.1 General . 9 5.2.2 Identification symbols . 10 5.2.3 Transformers w
8、ith alternative cooling methods 10 5.3 Temperature-rise limits 10 5.3.1 Classification and insulation system temperature 10 5.3.2 Normal temperature-rise limits 11 5.3.3 Reduced temperature-rises for transformers designed for high cooling air temperatures or special air cooling conditions . 11 5.3.4
9、 High altitude temperature-rise correction 11 5.3.5 Reduced temperature-rise for transformers designed for high cooling water temperatures 12 5.3.6 Temperature rise during specified load cycle 12 5.4 Insulation level 12 5.5 Load rejection on transformers directly connected to a generator . 12 5.6 Ra
10、ted voltage and rated frequency 12 5.7 Provision for unusual service conditions 12 5.8 Highest voltage for equipment Umand dielectric tests levels 12 5.9 Additional information required for enquiry . 12 5.10 Components and materials 12 5.11 Requirements for gases and gas tightness . 13 5.11.1 Requir
11、ements for gases . 13 5.11.2 Gas tightness . 13 6 Requirements for transformers having a tapped winding . 13 7 Connection phase displacement symbols . 13 8 Rating plates . 13 8.1 General . 13 8.2 Information to be given in all cases 13 8.3 Additional information to be given when applicable 14 9 Safe
12、ty, environmental and other requirements 15 9.1 Safety and environmental requirements . 15 9.1.1 Gas leaks 15 9.1.2 Safety considerations . 15 9.2 Dimensioning of neutral connection . 16 BS IEC 60076-15:2015IEC 60076-15:2015 IEC 2015 3 9.3 Handling procedure for SF6. 16 9.4 d.c. currents in neutral
13、circuits . 16 9.5 Centre of gravity marking 16 10 Tolerances 16 11 Tests . 16 11.1 General requirements for routine, type and special tests 16 11.1.1 General . 16 11.1.2 Routine tests 17 11.1.3 Type tests 18 11.1.4 Special tests 18 11.2 Measurement of short-circuit impedance and load loss . 19 11.3
14、Leak testing with pressure (tightness test) . 19 11.4 Pressure tests for tanks . 19 11.5 Temperature-rise test 20 11.5.1 General . 20 11.5.2 Corrections 20 11.6 Measurement of sound level 20 11.6.1 General . 20 11.6.2 Prescribed contour . 21 12 Electromagnetic compatibility (EMC) 21 13 High frequenc
15、y switching transients . 21 14 Earthing terminal . 21 15 Information required with enquiry and order 21 Annex A (informative) Check list of information to be provided with enquiry and order 22 A.1 Rating and general data 22 A.1.1 Normal information . 22 A.1.2 Special information 23 A.2 Parallel oper
16、ation 25 Annex B (informative) Transient loading Mathematical model 26 B.1 General . 26 B.2 Mathematical model for temperature distribution in a winding of a gas-filled power transformer The hot-spot concept . 26 Annex C (informative) Gauges, indicators and relays for gas-filled power transformers .
17、 28 Bibliography . 29 Figure B.1 Temperature distribution model . 26 Table 1 Classification and insulation system temperature . 11 Table 2 Winding temperature-rise limits 11 Table 3 Exponents for the corrections of temperature rise test results . 20 Table C.1 Comparison of gauges, indicators and rel
18、ays between gas-filled power transformers and oil-immersed power transformers 28 BS IEC 60076-15:2015 4 IEC 60076-15:2015 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ POWER TRANSFORMERS Part 15: Gas-filled power transformers FOREWORD 1) The International Electrotechnical Commission (IEC) is
19、a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to o
20、ther activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in th
21、e subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditio
22、ns determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC Nationa
23、l Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way i
24、n which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Pu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSIEC60076152015POWERTRANSFORMERSGASFILLEDPOWERTRANSFORMERS 电力变压器 充气 PDF

链接地址:http://www.mydoc123.com/p-582887.html