BS EN 61131-2-2007 Programmable controllers - Part 2 Equipment requirements nand tests《可编程控制器 第2部分 设备要求和试验》.pdf
《BS EN 61131-2-2007 Programmable controllers - Part 2 Equipment requirements nand tests《可编程控制器 第2部分 设备要求和试验》.pdf》由会员分享,可在线阅读,更多相关《BS EN 61131-2-2007 Programmable controllers - Part 2 Equipment requirements nand tests《可编程控制器 第2部分 设备要求和试验》.pdf(130页珍藏版)》请在麦多课文档分享上搜索。
1、Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 29/04/2008 04:03, Uncontrolled Copy, (c) BSIg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58a
2、nd testsThe European Standard EN 61131-2:2007 has the status of a British StandardICS 25.040.40; 35.240.50Programmable controllers Part 2: Equipment requirements BRITISH STANDARDBS EN 61131-2:2007BS EN 61131-2:2007Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 29/04/2008 04:03, Uncontrolled
3、Copy, (c) BSIThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2008 BSI 2008ISBN 978 0 580 55236 6Amendments issued since publicationAmd. No. Date Commentsrequest to its secretary.This publication does not purport to include all the
4、necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.National forewordThis British Standard is the UK implementation of EN 61131-2:2007. It is identical to IEC 61131-2:2007. It supersede
5、s BS EN 61131-2:2003 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee GEL/65, Measurement and control, to Subcommittee GEL/65/2, Elements of systems. A list of organizations represented on this committee can be obtained on EUROPEAN STANDARD EN 61131-2 N
6、ORME EUROPENNE EUROPISCHE NORM September 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of explo
7、itation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61131-2:2007 E ICS 35.240.50; 25.040.40 Supersedes EN 61131-2:2003English version Programmable controllers - Part 2: Equipment requirements and tests (IEC 61131-2:2007) Automates programmables - Partie 2: Spcifi
8、cations et essais des quipements (CEI 61131-2:2007) Speicherprogrammierbare Steuerungen - Teil 2: Betriebsmittelanforderungen und Prfungen (IEC 61131-2:2007) This European Standard was approved by CENELEC on 2007-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations wh
9、ich stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This Europea
10、n Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the
11、 national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
12、Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 29/04/2008 04:03, Uncontrolled Copy, (c) BSIForeword The text of document 65B/623/FDIS, future edition 3 of IEC 61131-2, prepared by SC 65B, Devices fast supply voltage variation test; slow supply volt
13、age variation test; gradual shut-down/start-up test. c) Change of EMC requirements in Clause 8: requirements for radiofrequency interference in Table 33 changed from 3 V to 10 V; for Zone B equipment; reference to EMC basic standards with the last version; reference to generic standards 61000-6-x; c
14、able length aligned to generic standards. d) Correction of the following tests in Clause 9: voltage dips and interruptions power port type tests and verifications. e) New organization of Clause 11: equipment types and protection; open PLC-system equipment; enclosed PLC-system equipment: Class I equi
15、pment, Class II equipment, Class III equipment; protection against electric shock; definition of secondary circuits which do not pose a risk of electric shock: Class 2 circuit, limited voltage/current circuit, limited voltage circuit, limited energy circuit 30 V a.c. or 42,2 V peak, limited impedanc
16、e circuit; protection against the spread of fire within limited power circuits; protective earthing requirements for enclosed equipment; minor improvements in different subclauses; impulse test only for verification of clearances. EN 61131-2:2007 2 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDAR
17、DS, 29/04/2008 04:03, Uncontrolled Copy, (c) BSIThe following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-05-01 latest date by which the national standards conflicting with the EN
18、have to be withdrawn (dow) 2010-08-01 This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directives EMC (89/336/EEC) and EMC2 (2004/108/EC). See Annex ZZ. Annexes ZA and
19、ZZ have been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61131-2:2007 was approved by CENELEC as a European Standard without any modification. _ EN 61131-2:2007 3 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 29/04/2008 04:03, Uncontrolled Copy, (c) BSI
20、CONTENTS INTRODUCTION.12 1 General 13 1.1 Scope and object.13 1.2 Compliance with this standard.14 1.3 Normative references 14 2 Type tests 17 2.1 Equipment to be tested (equipment under test/EUT)17 2.2 Special features for immunity and EMC tests.18 2.3 Withstand test conditions 19 2.4 Verification
21、procedure .19 2.5 Requirements for test programmes and proper functioning verification procedures (PFVPs) to be provided by the manufacturer.19 2.6 General conditions for tests.20 3 Terms and definitions .20 4 Normal service conditions and requirements.28 4.1 Climatic conditions and requirements 28
22、4.1.1 Operating ambient air temperature 28 4.1.2 Relative humidity.28 4.1.3 Altitude28 4.1.4 Pollution degree 29 4.2 Mechanical service conditions and requirements .29 4.2.1 Vibrations 29 4.2.2 Shock 29 4.2.3 Free falls (portable and hand-held equipment).30 4.3 Transport and storage conditions and r
23、equirements 30 4.3.1 Temperature30 4.3.2 Relative humidity.30 4.3.3 Altitude30 4.3.4 Free falls (PLC units in manufacturers original packaging)31 4.3.5 Other conditions 31 4.4 Electrical service conditions and requirements 31 4.4.1 AC and d.c. equipment power supply.31 4.4.2 Overvoltage category, co
24、ntrol of transient overvoltages.31 4.4.3 Non-periodic overvoltages .31 4.5 Special conditions and requirements .31 5 Functional requirements .31 5.1 Functional power supply and memory back-up requirements .33 5.1.1 AC and d.c. power supply33 5.1.2 Memory back-up34 5.2 Digital I/Os 34 5.2.1 Digital i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6113122007PROGRAMMABLECONTROLLERSPART2EQUIPMENTREQUIREMENTSNANDTESTS 可编程控制器 部分 设备 要求 试验 PDF

链接地址:http://www.mydoc123.com/p-576886.html