BS EN 50134-1-2002 Alarm systems - Social alarm systems - System requirements《警报系统 社会警报系统 系统要求》.pdf
《BS EN 50134-1-2002 Alarm systems - Social alarm systems - System requirements《警报系统 社会警报系统 系统要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50134-1-2002 Alarm systems - Social alarm systems - System requirements《警报系统 社会警报系统 系统要求》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 50134-1:2002 Alarm systems Social alarm systems Part 1: System requirements The European Standard EN 50134-1:2002 has the status of a British Standard ICS 13.320 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 50134-1:2002 This British Standard, hav
2、ing been prepared under the direction of the Consumer Products and Services Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 3 July 2002 BSI 3 July 2002 ISBN 0 580 40015 8 National foreword This British Standard is the official
3、 English language version of EN 50134-1:2002. The UK participation in its preparation was entrusted by Technical Committee GW/1, Electronic security systems, to Subcommittee GW/1/12, Social alarms, which has the responsibility to: A list of organizations represented on this subcommittee can be obtai
4、ned on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility o
5、f the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users of this publication are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from
6、legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK
7、. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDA
8、RD EN 50134-1 NORME EUROPENNE EUROPISCHE NORM June 2002 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2002 CENELEC - All right
9、s of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50134-1:2002 E ICS 13.320 English version Alarm systems - Social alarm systems Part 1: System requirements Systmes dalarme - Systmes dalarme sociale Partie 1: Rgles relatives aux systmes Alarmanlagen -
10、 Personen-Hilferufanlagen Teil 1: Systemanforderungen This European Standard was approved by CENELEC on 2002-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without
11、 any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language
12、made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Ger
13、many, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.EN 50134-1:2002 - 2 - Contents Page Introduction 4 1 Scope . 5 2 Normative references. 5 3 Definitions . 5 4 System requirements . 6 4.1 Local uni
14、t and controller identification. 7 4.2 Alarm and fault identification. 7 4.3 2-way speech communication facility. 7 4.4 Use of personal receiver(s) 7 4.5 Fault indication 7 4.6 Calling the user . 7 4.7 Logging alarm and fault conditions 7 4.8 System design. 8 4.9 Confirmation of alarm or fault recep
15、tion 8 5 Environmental classes. 8 6 Documentation 8 Annex A (normative) Functional elements of a social alarm system 9 Annex B (informative) Examples of different types of local unit andcontroller configurations . 10 Figures Figure A.1 - Functional elements of a social system. 9 Figure B.1 - Local u
16、nit and controller combined 10 Figure B 2 - Multiple local units connected to a single controller 11- 3 - EN 50134-1:2002 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 79, Alarm systems. The text of the draft was submitted to the formal vote and was approved by C
17、ENELEC as EN 50134-1 on 2002-06-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-06-01 - latest date by which the national standards conflicting with the EN have to
18、be withdrawn (dow) 2005-06-01 Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information only. In this standard, annex A is normative and annex B is informative. _EN 50134-1:2002 - 4 - Introduction A social alarm system provides 24
19、 hours facilities for alarm triggering, identification, signal transmission, alarm reception, logging and 2-way speech communication, to provide reassurance and assistance for people living at home and considered to be at risk. A social alarm system is comprised of a number of system parts which can
20、 be configured in different ways to provide this functionality. A user can request assistance by the use of a manually activated trigger device resulting in an alarm triggering signal. In certain cases, alarm triggering signals can be generated by automatic trigger devices. A local unit or controlle
21、r receives the alarm triggering signal, switching from the normal to the alarm condition and indicating this to the user (some systems use an optional pre-alarm condition that allows the user to reset the alarm for a short period of time). The controller normally transmits the alarm condition to an
22、Alarm Receiving Centre (ARC) via the alarm transmission system. The ARC can either be local to the controller or remote from the controller. The ARC has the facility to identify the local unit, alarm type and to then establish two-way speech communication between the alarm recipient and the user. Th
23、e alarm recipient provides reassurance to the user and directs assistance where appropriate. In some cases, the alarm may be diverted to an alarm recipient using a personal receiver. In this case, the alarm is identified to the alarm recipient and a two-way speech communication path established to t
24、he user and receipt of the alarm acknowledged to the controller. In all cases, the system records the time, date, location and type of alarm. The system is designed to detect and report fault conditions affecting the transmission of alarms. In some cases, temporary disconnection of a local unit is p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5013412002ALARMSYSTEMSSOCIALALARMSYSTEMSSYSTEMREQUIREMENTS 警报 系统 社会 要求 PDF

链接地址:http://www.mydoc123.com/p-574599.html